Release
- from this page it is possible to set the Release Time parameters of the RMS Compressor.
Once within the page, the RMS Compressor’s Threshold can be set by the PARAMETER encoder:
The selectable range of the RMS Compressor’s Release Time is from 0.1s to 5s in steps of 0.1s up
to 3s and 0.2 from 3s to 5s.
Attack
- from this page it is possible to set the Attack Time parameters of the RMS Compressor.
Once within the page, the RMS Compressor's Threshold can be set by the PARAMETER encoder:
The selectable range of the RMS Compressor’s Attack Time is from 5ms to 200ms, in steps of 1ms
from 5ms to 20ms, in steps of 5ms from 20ms to 30ms, in steps of 10ms from 30ms to 100ms and in
steps of 20ms - from 100ms to 200ms.
Make Up
- within this page, it is possible to set the signal level AFTER the RMS compressor to
make up the reduced level compressed signal, before the Peak Limiter.
The Gain can be set ranging between -12dBu and +12dBu, by steps of 0.5dBu:
Ch.A RMS Compr.
< Release = 1.1s >
Ch.A RMS Compr.
< Attack = 200ms >
Ch.A Volume
< 3.0dBu >
23