GPS 2300 PFC BI-PULSE
18
3.4.4.5. CYCLE PARAMETERS. PULSED MIG PROCESS (CONTINUOUS)
CYCLE PARAMETERS FOR PULSE MIG WELDING MODE IN CONTINUOUS CYCLE
2S/4S MOD (2/4 STROKES)
Torch
U
2
2T
I2>0
Vh
TPR
GAS
TBB
TPS
tacer
1T
3T
4T
FDC
1T
2T
2S-S/4S-S MODE (2/4 STROKES-SPECIAL)
Parameter
PARAMETER DESCRIPTION
CONFIGURABLE
VALUE
FACTORY VALUE
D
Drop detachment force correction.
-10 ÷ 10
(20 positions)
0
MOD
Pulse mode (2S, 2S-S, 4S and 4S-S)
2S; 2S-S; 4S; 4S-S
2S
TPR
Gas pre-flow time.
0÷3.0 s
0.3
(s)
TC
Striking ascent ramp time
0 ÷ 500 ms
130 ms
IS
Initial current (only in 2S-S and 4S-S mode)
5÷ 200 vh
200 % vh
TS
IS time
0.0÷5.0 s
0.1
CCE
U2 correction in IS
-30 +30%
0
DWS1
Start current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6 (s)
DWS2
END current ramp (only in 2S-S and 4S-S mode)
0÷10.0 s
0.6 (s)
IE
Final current
10 -200%
50%
TE
IE Time
0.0÷5.0 s
0.1 s
TPS
Gas post-flow time.
0.0÷5.0 s
0.5
(s)
FDC
Approach speed.
10 ÷100% Vh
33
(% vh)
TBB
After-burning time correction.
-20 ÷ 20 (ms)
0.00
DIM
Dimensional system (Ø/vh).
MM; IN
MM
REF
Cooling mode
AUT/ON/OFF
---
Explanatory notes:
Tacer: The time that it is in approach process (I
2
=0) will be limited to 5 s.
Tci: If the arc is manually interrupted (l2=0) during the welding process, the cycle will be suspended if the welding position (l2>0) is not recuperated
in 4 seconds.