GPS 2300 PFC BI-PULSE
6
2. TRANSPORT AND INSTALLATION.
2.1. TRANSPORT AND PACKAGING
Knocks and sudden movements must be avoided when transporting the equipment. In any case, the packaging must
be protected from water.
HANDLE THE EQUIPMENT CAREFULLY, IT WILL LAST LONGER !
2.2. ELECTRICAL SUPPLY INSTALLATION.
The electrical installation of the equipment making up the system must be carried out by specialised personnel
according to the applicable standards.
The location must fulfil the following conditions:
-
Place: Dry and ventilated. Far enough away from the welding area in order to prevent the dust caused by the
welding process from getting into the equipment. Never work in the rain.
-
The distribution panel where the machine has to be connected must have the following elements, at least:
EL
EC
TRIC
A
L
SUPP
LY
IN
STA
LL
A
TI
ON
.
HOME
CABLE PLUG
SOCKET AND ELECTRICAL PROTECTION DEVICES
“SCHUKO”
2P + T 16A
SOCKET
2P 16A + TT
MAGNETOTHERMAL
SWITCH
2P 16A-(230V)
The connection to the mains is made by the input hose. IMPORTANT! Verify that the wire is connected to a plug with
an efficient earth tap.
If you have special equipment, with power supply voltage other than 230 V, you will find the data for defining the
necessary electrical installation on the equipment characteristics plate.
Any supply voltage that is outside the rated margin gives rise to the activation of the protection system, preventing the
welding operation.
GPS 2300 PFC BI-PULSE
If it is necessary to use a longer power supply
hose or a connection to an extension, keep in
mind the values of this table. These values are for
reference and are influenced by the state of the
conductors, connections and ambient
temperature.
Length
CROSS-SECTION
5 m
2.5 mm
2
Up to 25 m
2.5 mm
2
>25 m
4 mm
2
ELECTRICAL INSTALLATIONS SHOULD ONLY BE HANDLED BY SPECIALISED PERSONNEL.
BEFORE STARTING THE EQUIPMENT, VERIFY THAT THE ELECTRODE-HOLDER CLAMP IS
SEPARATED FROM THE WELDING EARTH CLAMP.
DO NOT FORGET TO FIT THE EARTH CONNECTION INTO THE PLUG.
MAKE SURE THE MAINS VOLTAGE AGREES WITH THAT ESTABLISHED IN THE MACHINE.
Summary of Contents for GPS 2300 PFC BI-PULSE
Page 36: ...GPS 2300 PFC BI PULSE 36 NOTES...
Page 42: ......