CHAPTER 6. SAFETY MEASURES. 

 
 

The use of this equipment requires a maximum amount of responsibility with respect to their use and 

maintenance.  Read this safety chapter carefully as well as the rest of the instructions manual.  The correct use 
of the equipment will depend on this. 
 
 
 

 

 

 

 

 

 
 

 
 

For your safety and that of others, remember that: 

ANY PRECAUTION MAY BE INSUFFICIENT! 

 
 

The welding equipment referred to in this manual are electrical.  It is 

important therefore to observe the following safety measures. 
 

 

Any work on the equipment must only be carried out by specialists. 

 

The equipment must be connected to the earth connection and this must always 
be effective. 

 

The equipment must not be located in a damp place.  

 

Do not use the equipment if the welding or supply cables are damaged. Use 
original spares. 

 

Make sure that the part to be welded makes perfect electrical contact with the equipment ground. 

 

During any maintenance operations or when dismantling any element from the inside of the machine, this 
must be disconnected from the electricity supply. 

 

Do not touch the equipment switches when carrying out a welding operation. 

 

Never lean directly on the work part.  We will always work with protection gloves. 

 

Any work on the welding guns and ground will be done with the equipment disconnected (OFF Position (0) 
on the on/off switch).  Do not touch the electrically active parts (electrode-holder clip, ground, etc.) with 
your bare hand.  

 
 
 

 

 
 
 

 
 
 
 

 

 

 

 

 

 

 
 

 

 

 

 

 

 
 
 

 

 

 

 
 

The part to be worked on should be cleaned from possible grease or 

solvents as these may decompose during the welding process giving off fumes which 
could be very toxic.  This can also occur with those materials which have some kind 
of surface coating (zinc-plated, galvanised, etc.).  Avoid inhaling the fumes given off 
in the process at all times.  Protect yourself from the fumes and metal dust which can 
be given off. Use quality approved anti-fume goggles.  Work with this equipment 
must be carried out in places or working posts where there is suitable air renewal.  If 
welding processes are carried out in closed places the use of suitable fume 
extractors is recommended. 

 

 

In welding processes, the electric arc formed gives off infrared and 

ultraviolet type irradiations: these are harmful for the eyes and skin, so these areas 
must be suitably protected with gloves and suitable clothing.  The eyes must be 
protected with goggles with an quality approved protection system with a protection 
index of at least 11.  With electric arc welding machines use protection shield for the 
eyes and face.  With electric cutting machine use protection goggles.  Always use 
quality approved protection elements.  Never use contact lenses.  They may adhere 
to the cornea due to the great heat given off during the process. Bear in mind that 
the arc is considered to be dangerous within a 15 metre radius. 

 

 

Cast material projections are given off during the welding process so due 

precautions must be taken.  There must be a fire-extinguisher near to the working 
area.  Do not keep inflammable material or explosives near to the working post.  
Prevent fire caused by sparks or slag.  Use quality approved footwear for this type of 
operations.   

 

 

Never direct the path of a the electrode-holder clip towards people.  

 

 

Summary of Contents for GAR T

Page 1: ...380 50 Hz GAR 4T REF 468 86 000 220 380 50 Hz E ESTE EQUIPO DEBE SER UTILIZADO POR PROFESIONALES EN BENEFICIO DE SU TRABAJO LEA ATENTAMENTE ESTE MANUAL GB THIS EQUIPMENT MUST BE USED BY PROFESSIONALS...

Page 2: ...Page 10 CHAPTER 3 START UP OPERATION AND ADJUSTMENTS Page 11 CHAPTER 4 MAINTENANCE OPERATIONS RECOMMENDATIONS Page 12 CHAPTER 5 ANOMALIES PROBABLE CAUSES POSSIBLE SOLUTIONS Page 13 CHAPTER 6 SAFETY M...

Page 3: ...f cil y sencillo Las asas son ergon micas y el equipo dispone de c ncamo de elevaci n La regulaci n de la corriente de soldadura se realiza mediante un volante situado en la parte frontal del aparato...

Page 4: ...oducirse en el equipo No trabajar nunca bajo lluvia El cuadro de distribuci n en donde se debe conexionar la m quina debe estar compuesto al menos de los siguientes elementos INTERRUPTOR DIFERENCIAL I...

Page 5: ...Sit e la pinza y masa en las tomas D La polaridad ser determinada en funci n del trabajo a realizar v ase apartado 3 2 y 3 3 2 Regule la corriente de soldadura mediante el volante B 3 Accione el inte...

Page 6: ...mpia y seca es fundamental Debe soplarse el interior con la frecuencia que sea necesaria Debemos evitar cualquier anomal a o deterioro por la acumulaci n de polvo Sople con aire comprimido limpio y se...

Page 7: ...obar tensi n en entrada del rectificador 40V aproximadamente LA SOLDADURA ES A BAJA No existe alimentaci n el ctrica correcta Cambiar la toma de alimentaci n INTENSIDAD Cables de alimentaci n rotos o...

Page 8: ...istencia de grasas y disolventes dado que estas pueden descomponerse en el proceso de soldadura desprendiendo un humo que puede ser muy t xico Esto mismo puede suceder con aquellos materiales que inco...

Page 9: ...ansport easy and simple The handles are ergonomical and the equipment has a lifting eye The welding current is adjusted by means of a wheel located on the front of the appliance This system activates...

Page 10: ...t Never work in the rain The distribution panel where the machine has to be connected must be comprised of the following elements DIFFERENTIAL SWITCH ID Three pole or two pole with minimum sensitivity...

Page 11: ...lace the clip and ground in intakes D The polarity will be determined depending on the work to be carried out see section 3 2 and 3 3 2 Set the welding current with wheel B 3 Apply the on off switch A...

Page 12: ...rse que una vez soplado ste las conexiones el ctricas siguen correctamente apretadas The accumulation on the inside of metal dust is one of the main causes of breakdowns in this type of equipment as t...

Page 13: ...tput 40V approximately IT WORKS AT LOW INTENSITY The electrical supply is not correct Change the supply intake Supply cables broken or badly connected Repair connection Switch broken Change switch Loo...

Page 14: ...r solvents as these may decompose during the welding process giving off fumes which could be very toxic This can also occur with those materials which have some kind of surface coating zinc plated gal...

Page 15: ...l arri re permettent un transport facile et simple de l installation Les anses sont ergonomiques et l quipement dispose d un piton d l vation Le r glage du courant de soudage est r alis au moyen d un...

Page 16: ...t s introduire dans l quipement Ne jamais travailler sous la pluie Le cadre de distribution o doit tre branch e la machine sera compos au moins des l ments suivants INTERRUPTEUR DIFF RENTIEL ID Tripol...

Page 17: ...FF RENTES PHASES POUR LA MISE EN MARCHE DE L INSTALLATION 1 Placez la pince et la masse dans les prises D La polarit devra tre choisie en fonction du travail que vous devez r aliser voir annexe 3 2 et...

Page 18: ...et s che Il faut souffler l int rieur autant de fois qu il sera n cessaire Evitez toute anomalie ou toute d t rioration dues l accumulation de poussi re Soufflez avec de l air comprim propre et sec l...

Page 19: ...n l entr e du redresseur 40 V environ ELLE FONCTIONNE L alimentation lectrique n est pas correcte Changer la prise d alimentation EN FAIBLE INTENSIT C bles d alimentation ab m s ou mauvais branchement...

Page 20: ...probable de graisses et de dissolvants de la pi ce de travail tant donn qu ils peuvent se d composer lors du processus de soudage d gageant une fum e qui peut tre tr s toxique Il en est de m me avec d...

Page 21: ...a presencia en los alrededores de Cables de potencia control se alizaci n y tel fono Receptores y transmisores de radio y televisi n Ordenadores y otros equipos de control Equipo cr tico de seguridad...

Page 22: ...piezas descripci n y referencia de las mismas EJEMPLO GAR 4T Ref 468 00 000 220 380V 50Hz 1Ud SHUNT Ref 479 16 006 GENERAL GUARANTEE CONDITIONS GALA GAR guarantees correct operation against all manuf...

Page 23: ...s mauvais usage mauvais traitement accessoires inad quats service non autoris ou modification du produit non r alis par GALA GAR La d cision de r parer remplacer des pi ces ou fournir un nouvel appare...

Page 24: ...CAL CONSTRUCTIONS FABRICATION ET VENTE D APPAREILS DE SOUDAGE AUTOG NE LECTRIQUE ET CONSTRUCTIONS LECTROM CANIQUES FABRICO E VENDA DE APARELHAGENS DE SOLDADURA AUTOG NEA EL CTRICA E CONSTRU ES ELECTRO...

Reviews: