en
Troubleshooting
58
Fault
Cause and troubleshooting
The drying time is too
long.
Remote start is activated and the ambient temperature
is lower than 16 °C.
▶
Ensure that the ambient temperature is above 16
°C or start the next drying process within 2 hours.
→
"Please clean lint fil-
ter" and the appli-
ance is not respond-
ing to operation.
The ambient temperature is low and the base unit fil-
ter is damp.
1.
"Cleaning the filter system on the base unit",
2.
Dry the filter thoroughly after cleaning.
3.
"Closing the base unit", Page 51
4.
"Switching off the appliance", Page 36
5.
"Switching on the appliance", Page 35
.
6.
"Starting the programme", Page 35
"Selfcleaning"
Automatic self-cleaning function rinses the appliance's
heat exchanger.
1.
Not a fault.
2.
Do not pull out the condensation tank.
3.
Do not cancel the programme.
Water is leaking from
the appliance.
Appliance is not correctly aligned.
▶
"Aligning the appliance", Page 16
The seal for the heat exchanger cover is dirty.
▶
Clean the seal for the heat exchanger cover.
→
"Cleaning the filter system on the base unit",
Water drain hose is not connected correctly.
▶
Ensure that the water drain hose is connected cor-
rectly.
→
"Connecting the water drain hose", Page 14
The lever for the heat exchanger cover is not closed
correctly.
▶
Ensure that the lever for the heat exchanger cover
is closed correctly.
→
"Closing the base unit", Page 51
"Refresher-container
is empty, please re-
fill."
The water tank for the crease-removal function is
empty.
▶
Fill water tank.
→