7
Wate
r
connect
i
ons
The appliance requires a freshwater supply and
wastewater drainage. The freshwater hose and the
outlet hose are permanently fitted to the appliance.
!
Wa
r
n
i
ng!
Disconnect the appliance from the electricity mains
before carrying out any work on the water
connection.
Do not immerse the AquaStop valve in water.
The water connection must only be installed by a
qualified plumber and in accordance with local
legislation and regulations governing water quality.
Note!
Do not kink, pinch, modify or cut through the outlet
hose or the freshwater hose with AquaStop valve.
Otherwise, their strength and operational reliability
would no longer be guaranteed.
Locat
i
on of the wate
r
connect
i
ons
The water connections can be on the right or lefthand
side of the appliance.
During installation of the water connection, the
permissible installation zones of the water lines must be
taken into consideration.
The following illustration shows the possible connection
zones with a hose length of 2.3 m.
400
1200
800
100
Lefthand
connection zone
Righthand
connection zone
max.
1000
Out
l
et connect
i
on
With a hose length of up to 6 m, the outlet connection
must be installed no higher than 1 m.
With a hose length of over 6 m, the maximum
installation height decreases by 0.1 with each additional
metre.
The outlet hose has a plugtype connection and can be
connected to a 3/4inch thread using the supplied
coupling piece.
A hose extension (2.3 m long) and a reducer for
connecting to a 1inchconnection can be ordered as
accessories. See "Tools and accessories".
Note!
The outlet connection on the appliance has no
check valve. If connected incorrectly, there is a risk
of flooding caused by returning waste water. Do not
connect the appliance to the drainage system in
conjunction with other appliances, e.g. using a
Tpiece. The outlet connection of the appliance
must not be lower than the wastes of other
appliances.
Always connect the appliance directly to the
drainage system and above the wastes of other
appliances, e.g. dishwashers.
F
r
eshwate
r
connect
i
on
A coldwater connection is required for operation of the
automatic ice maker. The water pressure must be
between 1 and 10 bar. A pressure reducing valve must
be fitted if the water supply pressure is over 10 bar. The
automatic ice maker is inoperable with a water pressure
of below 1 bar.
A separate stop valve must be installed in the
freshwater supply line.
The stop valve must not be located behind the
appliance. It is recommended that the stop valve be
fitted directly next to the appliance or in another easily
accessible area.
The freshwater hose has a 3/4inchconnection.
A hose extension (2.3 m long) and a reducer for
connecting to a 1inchconnection can be ordered as
accessories. See "Tools and accessories".
In order not to affect the taste of the water, only original
hose extensions are permitted to be used. These are
neutral to taste and are food safe.