Basic settings
en
21
Display
Selection
Setting air recirculation mode or air extrac-
tion mode
Air recirculation mode is set.
1
Air extraction mode is set.
Automatic ventilation start
Switched off. The ventilation must be
switched on manually if required.
Switched on in automatic mode.
1
The
ventilation switches itself on when you
switch on a cooking zone in automatic
mode.
/ / Switched on in manual mode. The
ventilation is switched on with a fixed
power level when a cooking zone is
switched on.
Fan run-on
Fan run-on in automatic mode.
1
Fan run-on with last selected setting.
The ventilation system is switched off
with the hob. Not recommended for appli-
ances with air recirculation mode.
Setting the sensor sensitivity for the ventil-
ation
Lowest sensor sensitivity setting.
Medium sensor sensitivity setting.
1
Highest sensor sensitivity setting.
Restoring to the factory settings
Individual settings retained.
1
Restore to the factory settings.
1
Factory setting
16.2 Opening the basic settings menu
Requirement:
The hob is switched off.
1.
Push in any control knob. While the control knob is
pushed in, carry out the following steps without in-
terruption:
‒
Turn the control knob one notch anti-clockwise to
position .
‒
Turn the control knob three notches clockwise to
position .
‒
Turn the control knob two notches anti-clockwise
to position .
a
lights up.
a
The illuminated ring on the control knob lights up
yellow.
2.
Press .
The displays show the product information.
Product information
Display
Customer Service Index
Production number
Production number 1
.
Production number 2
3.
Press again.
a
The basic settings menu is opened.
a
and
light up.
4.
Press repeatedly until the required function is dis-
played.
5.
Use and to select the required setting.
6.
Press and hold for at least 4 seconds.
a
The settings are saved.
7.