background image

Inertia Electric Radiators  

 

WEEKLY PROGRAMMES 
 

It is possible to allocate different programs to different days of the week. To do this, the controller has to be upgrade from 24hr mode (factory 
default) to 24hr/7days mode as follows: 
 
Move the selector to 

0

 position, the display will be Off. Press the 

 key and at the same time turn the selector to 

P

 position maintaining the 

 

key at least five seconds. The display will show 

P-SE

 which means that weekly mode has been set.

 

 
SETTING THE DAY: Press the 

 key more than two seconds and the display will show the number of the day. Set the correct number, if required, 

by pressing 

+

 or 

 keys. Press the 

 key and the display will show now the time.  Press again the 

 key and new values will be stored. 

 
 
To check a programme or to make a new one press

  PRG 

key: The display will show 

dia1

 .  Press again 

PRG 

key and the display will 

show 

00:00 

intermittently.  Follow  now  the  steps  from  DAILY  PROGRAMMES  section  until  the  display  shows  again   

dia1

  .    Repeat  this 

process with the 7 days of the week. When the display shows 

dia7

  the weekly program will be stored by pressing 

+

 key.  

 

 If the display shows 

dia1

 

then, pr key more than three seconds will copy the day 1 program to day 2 and so on. 

 

It is possible to allocate any of the three temperature levels to all the intervals of any day maintaining the relevant  

    

   

T

 

key 

until an audible signal is heard. 
 

 
To turn back a controller from 24hr/7days to a single 24hr press 

PRG 

key more than six seconds. This will restore the factory default settings. 

 
KEYBOARD LOCK 

Press  the 

T

  key  more  than  six  seconds  and  the  keyboard  will  be  locked.  The  display  will  show 

 

  and  the  controller  will  keep  on 

working internally.  To unlock the keyboard press again the 

T

 key more than six seconds. 

 
 

4.- CLEANING AND MAINTENANCE  

 

Clean and dust with a dry, soft cloth only when the unit is disconnected and cold.  
 
Do not use solvents or abrasive products for cleaning. 
 
This thermal radiator has been manufactured under an assured quality system using environment friendly processes.                 
 
Please take the heaters to a clean point once their useful life is finished, in order to recycle their materials in the right way. 
 
 
 

5.- TROUBLESHOOTING 

 

- The thermal radiator does not heat. 

Check the heater or the air inlets are not covered.  

Digital models:  the display shows the time press the 

T

 key to switch on the heater. Check that the DAY 

or NIGHT temperatures are right. 

 

- The room does not reach the right 
 temperature.  

Check  the  selected  temperature  is  in  accordance  with  the  desired  temperature.  Maybe  the  room  needs 
more heating power. 

 

- DAY and NIGHT luminous indicators 
are lit at the same time. 

Digital  models:  Continuous  mode  has  been  selected.  Turn  the  knob  to  the  “P”  position  to  return  to  the 
Program mode if required. 

 

- The display shows “Err1” or “Err2”  

Digital models: Contact the after sale service. 

 

- Only daily programmes.

 

The controller is in a single 24hr mode (factory default). See WEEKLY PROGRAMMES section to swift to 
24hr/7days mode. 

- The keyboard is locked.

 

If the display shows 

 

the keyboard is locked. To unlock the keyboard press the 

T

 key more 

than six seconds. 

Summary of Contents for RF3P

Page 1: ...TIA ELECTRIC RADIATOR RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF3F RF4F RF5F RF6F RF8F RF10F RF12F RF3E RF4E RF5E RF6E RF8E RF10E RF12E Please read these instructions before installing or using this appl...

Page 2: ...tion It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a do...

Page 3: ...15cm Closest object to the right end minimum 25cm minimum 10cm Closest object to the left end minimum15cm The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By...

Page 4: ...s in frost protection mode at this stage if the room temperature drops below 3 C the heater will connect itself automatically There are three selectable positions with the mode selector dial 0 The hea...

Page 5: ...ossible to modify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys...

Page 6: ...the heater is frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is r...

Page 7: ...the display shows the time the heater is in frost protection mode Press the T key to shift from frost protection mode time is shown in the display to standard mode temperature is shown in the display...

Page 8: ...ify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be use also to store the...

Page 9: ...key more than six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller w...

Page 10: ...ctric Radiators 10 WIRING MODELS RF P R heating element Ts safety cut out C three way selector MODELS RF F R heating element Ts safety cut out MODELS RF E R heating element Ts safety cut out C three w...

Page 11: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise...

Page 12: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...

Reviews: