Inertia Electric Radiators  

 

  

INSTALLATION INSTRUCTIONS

 

1.- WARNING   

 

  The warranty of the heater will not cover any damage caused by non observance of any of these instructions. 

  This guide must be kept and given to any new owner. 

  Please check that the voltage in the rating label fits the power supply. 

  Any reinstallation should be carried out by trained personnel. 

  The use of these heaters is forbidden in any area where there is a presence of gases, explosives or inflammable objects. 

  DO NOT USE THIS HEATER TO DRY CLOTHES. 

  The surfaces of this heater can be hot, so young children should not be left unsupervised in the vicinity of the heater. 

  Children should be supervised to ensure they do not play with the appliance. 

  Neither the connecting cable nor any other object must come into contact with the hot unit. 

  Do not cover this heater at any time. 

  The air outlet at the top of the thermal radiator and the air inlet at the bottom are provided to ensure the most efficient operation 

of the appliance. They also protect the heater from overheating; therefore, it is essential that at no time are they covered. 

  This heater should be switched off at the isolating switch before any repair work is carried out. 

  The thermal radiator should not be installed just below an electrical socket. 

  The appliance must be installed in such a way that it is impossible for anyone using a bath or shower, to touch the controls. 

  The installation must be carried out in accordance with the current electrical regulations. 

  The heater is fitted with a flexible cable size 3 x 1.00 mm2 for electrical connection. It may be used to connect the heater to the 

fixed wiring of the premised through a suitable connection box positioned adjacent to the heater.  

  The supply circuit to the heater must incorporate a double pole isolating switch having a contact separation of at least 3 mm. 

  If the flexible power cable for this unit is damaged, it may only be replaced by a repair workshop recognised by the manufacturer, 

as special tools are necessary. 

  This appliance is not intended for use by persons with reduced physical, sensory or mental capabilities, or lack of experience and 

knowledge, unless they have been given supervision or instruction concerning the use of the appliance by a person responsible 
for their safety. 

  This appliance must be earthed. 

  All models are supplied with an electrical interrupt cut-out. This will switch off the heater if, for any reason, it overheats. Should 

the cut-out operate, turn the heater off and remove the cause for the overheating. The cut-out will be reset automatically. 

  The  presence  of  air  particles  of  smoke,  dust  and  other  pollutants  could,  in  time,  discolour  the  walls  and  surfaces  around  the 

heater. 

  This heater is filled with a precise quantity of special oil. Repairs requiring the opening of the oil container are only to be made by 

the manufacturer or his service agent who should be contacted if there is an oil leakage. 

  Regulations concerning the disposal of oil when scrapping the appliance have to be followed. 

 
 

MODELS 

RF3P 
RF3F 
RF3E 

RF4P 
RF4F 
RF4E 

RF5P 
RF5F 
RF5E 

RF6P 
RF6F 
RF6E 

RF8P 
RF8F 
RF8E 

RF10P 
RF10F 
RF10E 

RF12P 
RF12F 
RF12E 

MODULES 

10 

12 

W (cm) 

33.5 

41.5 

49.5 

57.5 

73.5 

89.5 

105.5 

D (cm) 

10 plus 2 cm separated from the wall 

H (cm) 

58 

WEIGHT (kg) 

7,5 

9,5 

11,5 

13,5 

17,5 

21,5 

25,5 

VOLTAGE 

220-240V~ 

INPUT (W) 

375 

500 

625 

750 

1000 

1250 

1500 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Summary of Contents for RF3P

Page 1: ...TIA ELECTRIC RADIATOR RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF3F RF4F RF5F RF6F RF8F RF10F RF12F RF3E RF4E RF5E RF6E RF8E RF10E RF12E Please read these instructions before installing or using this appl...

Page 2: ...tion It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a do...

Page 3: ...15cm Closest object to the right end minimum 25cm minimum 10cm Closest object to the left end minimum15cm The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By...

Page 4: ...s in frost protection mode at this stage if the room temperature drops below 3 C the heater will connect itself automatically There are three selectable positions with the mode selector dial 0 The hea...

Page 5: ...ossible to modify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys...

Page 6: ...the heater is frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is r...

Page 7: ...the display shows the time the heater is in frost protection mode Press the T key to shift from frost protection mode time is shown in the display to standard mode temperature is shown in the display...

Page 8: ...ify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be use also to store the...

Page 9: ...key more than six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller w...

Page 10: ...ctric Radiators 10 WIRING MODELS RF P R heating element Ts safety cut out C three way selector MODELS RF F R heating element Ts safety cut out MODELS RF E R heating element Ts safety cut out C three w...

Page 11: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise...

Page 12: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...

Reviews: