background image

Inertia Electric Radiators  

 

DIGITALS MODELS RFE 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Digital models have built in an electronic thermostat with a sensibility of 0.1 ºC. It is possible to set temperatures with an accuracy of 0.5ºC. 
 
The daily or weekly programmer (selectable) allows you to allocate three different temperature levels to any of the 48 intervals of 30 minutes of the 
day.  
 

SWITCHING ON THE HEATER AND SETTING THE TIME 

Turn the mode selector dial to 

P

 position and press the 

  key more than two seconds. The display will show the time intermittently. Set the 

minutes by pressing 

+

 and 

-

  keys and press the 

 . Set the hours the same way. Press once more the 

  key to store the time. If at any time it 

is necessary to set the time press the 

 key and repeat the above steps. 

 

 
FROST PROTECTION MODE

T

 
With this mode on, if the room temperature drops below 3ºC the heater will connect itself automatically. 
If  the  display  shows  the  time  the  heater  is  in  frost  protection  mode.  Press  the 

T

  key  to  shift  from  frost  protection  mode  (time  is  shown  in  the 

display) to standard mode (temperature is shown in the display) and vice versa. 
 

SELECTOR “O” , “P”,  “I”. 
 

Position “0” :  The heater is switched off permanently. The display is switched off.  
 
Position “P” :   The  heater  is  following  a  program.  It  will  maintain  the  SUN,  MOON  or 

T

  temperatures  as  per  the  introduced  program.  At  this 

position if the display shows the time the heater is frost protection mode. 

 
Position “I” :   The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit. This could be useful 

when  SUN  temperature  is  required  and  we  do  not  want  to  modify  the  program.  At  this  position  if  the  display  shows  the  time  the 
heater is in frost protection mode.

 

Press the 

T

 key to shift from frost protection mode (time is shown in the display) to standard 

mode (temperature is shown in the display) and vice versa. 

 

 

Digital DISPLAY: 

It 

shows 

the 

time, 

temperature 

and 

other 

messages. 

Frost protection key: 

If  the  display  shows  the  time 
the heater is in frost protection 
mode.  Press  this  key  to  shift 
from  frost  protection  mode  to 
standard mode and vice versa. 

Heating indicator: 

This  small  dot  will  be  lit  when 
the  heater  is  consuming 
energy. 

SUN indicator 

Press  this  key  for  more  than 
two seconds to set the time or 
day of the week. 

PRG key:  

Allows  you  to  create  check 
or modify programs. 
Move  forward  with  +  or  – 
keys  and  allocate  the  SUN, 
MOON, or 

T

 temperature to 

any of the 48 intervals of 30 
minutes of the day by means 
of the relevant key. 

Key   +   : 

It increases the 
values. 

SUN key: 

Press once to see the SUN 
temperature value. 
Press + or – keys to modify 
the value. 

MOON key: 

Press  once  to  see  the 
MOON  temperature  value. 
Press + or – keys to modify 
the value. 

 

MOON indicator 

Key: 

It decreases the 
values. 

Selector:  

0     The heater is switched off 

permanently. 

 
P  The  heater  is  following  a 

program. 

 
I   The  heater  is  maintaining 

the 

SUN 

temperature 

constantly. Both indicators 
will be lit at the same time.  

Summary of Contents for RF3P

Page 1: ...TIA ELECTRIC RADIATOR RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF3F RF4F RF5F RF6F RF8F RF10F RF12F RF3E RF4E RF5E RF6E RF8E RF10E RF12E Please read these instructions before installing or using this appl...

Page 2: ...tion It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a do...

Page 3: ...15cm Closest object to the right end minimum 25cm minimum 10cm Closest object to the left end minimum15cm The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By...

Page 4: ...s in frost protection mode at this stage if the room temperature drops below 3 C the heater will connect itself automatically There are three selectable positions with the mode selector dial 0 The hea...

Page 5: ...ossible to modify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys...

Page 6: ...the heater is frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is r...

Page 7: ...the display shows the time the heater is in frost protection mode Press the T key to shift from frost protection mode time is shown in the display to standard mode temperature is shown in the display...

Page 8: ...ify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be use also to store the...

Page 9: ...key more than six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller w...

Page 10: ...ctric Radiators 10 WIRING MODELS RF P R heating element Ts safety cut out C three way selector MODELS RF F R heating element Ts safety cut out MODELS RF E R heating element Ts safety cut out C three w...

Page 11: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise...

Page 12: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...