background image

Inertia Electric Radiators  

 

 
DAILY PROGRAMMES 

It is basic to visualize the day split into 48 intervals of 30 minutes each; SUN, MOON, or 

T

 temperatures can be allocated to any of them. 

The default settings include daily mode so that the heater will repeat the program every day. If different programmes are required along a week, 
please see the next step WEEKLY PROGRAMMES. To check a programme or to make a new one follow these steps: 

Press the 

PRG

 key and the display will show 

00:00

 intermittently.  Press one of the three keys 

    

   

T

   to allocate SUN, MOON or 

OFF  (frost  protection)  from  00:00h  to  00:30h.  If  SUN  or  MOON  temperatures  are  selected  the  relevant  luminous  indicator  will  be  lit.  If  OFF 
temperature 

T

 

is selected both luminous indicators will be off.

 

 

Press the 

+

 key to go to the next interval. The display will show 

00:30

 intermittently and, again, press one of the three keys 

    

   

T

   

to allocate SUN, MOON or OFF (frost protection) from 00:30h to 01:00h or press 

+

 key directly if the existing temperature level is ok. 

Repeat these steps allocating the desired temperatures levels over the 24 hours of the day. Press the 

– 

key at any time to modify a previous 

period.  By reaching the 

23:30

  in the display and pressing  

+

 key  the controller will store the program and will return to the previous mode. 

At any time 

PRG 

key can be use also to store the program and return the previous mode. 

 
 

 

 

1 - Press 

PRG  

 

 

 

 

00:00

 

2 - Press 

T

  

 

 

 

 

     

Off 

 

 

 

3 - Press 

key

 

 

 

 

 

00:30 

 

4 - Repeat steps 2 and 3 until display shows: 

 

07:30

 

5 - Press  

 

 

 

 

 

     

On 

6 - Press 

key

 

 

 

 

 

08:00 

 

7 - Press  

 

 

 

 

 

 

8 - Press 

key

 

 

 

 

 

08:30  

9 - Press  

 

 

 

 

 

 

10 - Press 

key

 

 

 

 

 

09:00 

 

11 - Press 

 

 

 

 

 

 

12 - Press 

key 

 

 

 

 

09:30 

 

13 - Repeat steps 11 and 12 until display shows: 

 

13:00

 

14 - Press  

 

 

 

 

 

 

15 - Press 

key

 

 

 

 

 

13:30 

 

16 - Repeat steps 14 and 15 until display shows: 

 

15:00

 

17 - Press 

 

 

 

 

 

 

18 - Press 

key

 

 

 

 

 

15:30 

 

19 - Repeat steps 17 and 18 until display shows: 

 

19:30

 

20 - Press  

 

 

 

 

 

 

21 - Press 

key

 

 

 

 

 

20:00 

 

22 - Repeat steps 20 and 21 until display shows::

    

23:30

 

23 - Press  

 

 

 

 

 

 

24 - Press 

key

 

 

 

 

 

GRAB

 

00:00

 

01:00

 

02:00

 

03:00

 

04:00

 

05:00

 

06:00

 

07:00

 

08:00

 

09:00

 

10:00

 

11:00

 

12:00

 

13:00

 

14:00

 

15:00

 

16:00

 

17:00

 

18:00

 

19:00

 

20:00

 

21:00

 

22:00

 

23:00

 

24:00

 

T

 

SUN

 

MOON

 

OFF

 

EXAMPLE

 

 
Let’s see an example of how to introduce a 
program  with  the  above  distribution  of 
temperatures. 
 
OFF  from  24:00h  to  7:30h  in  the  morning. 
The heater will be on only if the temperature 
drops to 3ºC. 
 
SUN temperature from 7:30h to 9:00h. 
 
MOON temperature from 9:00h to 13:00h. 
 
SUN temperature from 13:00h to 15:00h. 
 
MOON temperature from 15:00h to 19:30h. 
 
SUN temperature from 19:30h to 24:00h. 

Summary of Contents for RF3P

Page 1: ...TIA ELECTRIC RADIATOR RF3P RF4P RF5P RF6P RF8P RF10P RF12P RF3F RF4F RF5F RF6F RF8F RF10F RF12F RF3E RF4E RF5E RF6E RF8E RF10E RF12E Please read these instructions before installing or using this appl...

Page 2: ...tion It may be used to connect the heater to the fixed wiring of the premised through a suitable connection box positioned adjacent to the heater The supply circuit to the heater must incorporate a do...

Page 3: ...15cm Closest object to the right end minimum 25cm minimum 10cm Closest object to the left end minimum15cm The studs and screws are in the accessories bag Hung the unit on the hooks of the brackets By...

Page 4: ...s in frost protection mode at this stage if the room temperature drops below 3 C the heater will connect itself automatically There are three selectable positions with the mode selector dial 0 The hea...

Page 5: ...ossible to modify the set back value from 3 C to a different one Press the key four seconds and the display will show 3 0 as the factory default value Increase or decrease the value using the and keys...

Page 6: ...the heater is frost protection mode Position I The heater is maintaining the SUN temperature constantly both luminous indicators SUN and MOON will be lit This could be useful when SUN temperature is r...

Page 7: ...the display shows the time the heater is in frost protection mode Press the T key to shift from frost protection mode time is shown in the display to standard mode temperature is shown in the display...

Page 8: ...ify a previous period By reaching the 23 30 in the display and pressing key the controller will store the program and will return to the previous mode At any time PRG key can be use also to store the...

Page 9: ...key more than six seconds This will restore the factory default settings KEYBOARD LOCK Press the T key more than six seconds and the keyboard will be locked The display will show and the controller w...

Page 10: ...ctric Radiators 10 WIRING MODELS RF P R heating element Ts safety cut out C three way selector MODELS RF F R heating element Ts safety cut out MODELS RF E R heating element Ts safety cut out C three w...

Page 11: ...electrical and electronic equipment By ensuring this product is disposed of correctly you will help prevent potential negative consequences for the environment and human health which could otherwise...

Page 12: ...ION INSTRUCTIONS AND USER GUIDE WEB VERSION ELNUR UK Ltd Unit 1 Brown Street North Leigh Lancashire WN7 1BU www elnur co uk Customer Service Department Telephone 44 0 1942 670119 technical elnur co uk...