46
Power and data transmission unit
Mounting und operating instructions
SECUREconnect 200
12.2013 | 15887EE | Printed in Germany
EN
5.3 Regulating the rebate clearance
The factory setting of SECURE
connect
200F regarding the rebate clearance
is 0 - 6 mm. For increasing this value to 6 - 12 mm, it is possible to pull out
the restricting brackets on the side of the tappet contacts using a small
screwdriver. In doing so, the adhesive label "Hubverstellung der Kontakte"
(adjustment of contact travel) must be removed carefully and re-attached
afterwards. The tappet contacts now protrude 12 mm from the device.
Do not reinsert the restriction brackets with the rebate clearance set
to 6 - 12 mm !
If you wish to limit SECURE
connect
200F to a rebate clearance of 6 mm
again, press back the tappet contacts until stop and reinsert the restricting
brackets.
Do not adjust to 6 - 12 mm rebate clearance if the
clearance is smaller than 6 mm. This would increase
the strain on the contacts and reduce the service
life of the device.
ATTENTION
Reattach the adhesive label for protection !