44
Power and data transmission unit
Mounting und operating instructions
SECUREconnect 200
12.2013 | 15887EE | Printed in Germany
EN
The door leaf part of SECURE
connect
has an integral energy storage
ensuring that in the event of a power failure during short-time 'OPEN',
the retracted latchbolts of all mechatronic GU-BKS locks will eject to be
ready for locking. This provides for safe and reliable door locking in the
event of a fire.
SECURE
connect
200R features an internal 2 A fuse which is not
accessible from outside and not suitable for being exchanged. Opening
the device will damage it and nullify its warranty.
Disconnecting the unit from the mains is done by pulling the power plug
from the socket.
The socket must be freely accessible.
If SECURE
connect
200 is connected to the electricity supply
permanently, it is necessary to provide for switch off by means of a
suitable and appropriately marked device on the building's distribution
board, e.g. a switch, fuse, or automatic cutout.
This manual is part of the product and must remain with the end user.
5.
Mounting preparations
The electronic components should be installed with utmost care since
chafed or defective cables, damaged contacts etc. may seriously affect the
safety of the system and cause its failure. Ensure that all components are in
faultless state before mounting them.
5.1 Mounting the faceplates
Attach SECURE
connect
200R and SECURE
connect
200F to the
corresponding faceplate, each, using the special 4 x 7 Torx screws included
in the bag (8 altogether).
Tighten screws with a max. torque of 1.0 Nm using a TORX T20 suitable tool
only.
It is imperative to observe the attached assembly
drawing!
ATTENTION