The output is connected to a battery with incorrect
polarity.
This will be displayed in case of detecting an
interruption of the connection between battery and
output or voluntarily disconnecting the charge lead
during the operation.
The cell-count of Lithium battery pack was selected
incorrectly. Verify the cell-count carefully.
There happens the malfunction at the charger circuit
by any reason. The charger should be repaired at
the factory.
There is a short-circuit at output. Please check the
charging leads or output cable of battery pack.
The charger detects the voltage is lower than you
set at Lithium program. Please check the cell-count
of the battery pack.
The charge detects the voltage is higher than you
set at Lithium program. Please check the cell-count
of the battery pack.
The balancing circuit had been damaged. The
balance function can not be used, and the charger
needs to be repaired at our factory.
The voltage of one of the cell in the Lithium battery
pack is too low. Please check the voltage of cells
one by one.
The voltage of one of the cell in the Lithium battery
pack is too high. Please check the voltage of cells
one by one.
There are bad connection at the individual
connector. Please check the connector and cables
carefully.
The charger cannot read out the individual voltage
correctly because of malfunction of main processor.
The charger needs to be repaired.
The voltage of input power drops below the limit.
Check connection ---
Reversed polarity
STOP/ESC
STOP/ESC
Check connection ---
Connection break
Check cell-count ---
Incorrect cell-count
Check charger ---
Break-down
Check connection ---
Short-circuit
Check battery ---
Low voltage
Check battery ---
High voltage
Check balancer ---
Comm. Error
Balance error ---
Low cell vol.
Balance error ---
High cell vol.
Balance error ---
Bad connection
Balance error ---
Ref. Data fail
Check power ---
Low input volt
Manual of the charger E6D