14
LI0083 – Revision 22 June 2017
Monitoring
Monitor Conditioning<cr>
sets monitor to Conditioning Amplifier Output.
Monitor Speaker in<cr>
sets monitor to Speaker Amplifier Input.
Monitor Speaker out <cr>
sets monitor to Speaker Amplifier Output.
Monitor Current<cr>
sets monitor to Current Amplifier Output.
MLATCH<cr>
set the Speaker Amplifier to latch current overloads.
Overload’s are latched, and cleared when read. No
overload messages will be sent.
The Monitor Conditioning amplifier does not sent overload messages.
Special Commands
MSG<cr>
set the Conditioning amplifier to submit an overload
message when its overload status changes, returns
actual overload status:
OVL_on <crlf>
or
OVL_
off<crlf>
, overload is not latched.
OVL<cr>
reads overload status, and returns
OVL_on <crlf>
or
OVL_off <crlf>
. Latched overloads will be reset by
reading the status.
SMSG<cr>
set the speaker amplifier to submit an overload
message when its voltages overload status changes,
returns actual overload status:
SOVL_on <crlf>
or
SOVL_off <crlf>
, overload is not latched.
SOVL<cr>
reads overload status, and returns
SOVL_on <crlf>
or
SOVL_off <crlf>
. Latched overloads will be reset
by reading the status.
CMSG<cr>
set the Speaker amplifier to submit an overload
message when its current overload status changes,
returns actual overload status:
COVL_on <crlf>
or
COVL_off <crlf>
, overload is not latched.
COVL<cr>
reads overload status, and returns
COVL_on <crlf>
or
COVL_off <crlf>
. Latched overloads will be reset
by reading the status.
MMSG<cr>
set the Monitor rear output to submit an overload
message when its overload status changes, returns
actual overload status:
MOVL_on <crlf>
or
MOVL_
off <crlf>
, overload is not latched.