4 DMX-512 connection/connection between fixtures 

 

 

 

 

 

 

 

 

 

 

 

The wires must not come into contact with each other; otherwise the fixtures will not 

work at all, or will not work properly. 

 

 

Only  use  a  stereo  shielded  cable  and  3-pin  XLR-plugs  and  connectors  in  order  to  connect 

the controller with the fixture or one fixture with another. 

Occupation of XLR-connection: 

 

 

 

 

 

 

 

 

 

 

 

If  you  are  using  controllers  with  this  occupation,  you  can  connect  the  DMX-output  of  the 

controller  directly  with  the  DMX-input  of  the  first  fixture  in  the  DMX-chain.  If  you  wish  to 

connect DMX-controllers with other XLR-outputs, you need to use adapter-cables. 

Building a serial DMX-chain: 

Connect the DMX-output of the first fixture in the DMX-chain with the DMX-input of the next 

fixture.  Always  connect  one  output  with  the  input  of  the  next  fixture  until  all  fixtures  are 

connected. 

Summary of Contents for 250S

Page 1: ...www g lites com 1 User Manual MOVING HEAD MODEL 250S...

Page 2: ...INSTALLATION 8 5 1 INSTALLING REPLACING THE LAMP 8 5 2 LAMP ADJUSTMENT 9 5 3 RIGGING 9 5 4 DMX 512CONNECTION CONNECTIONBETWEENFIXTURES 12 5 5 CONNECTIONWITH THE MAINS 13 6 OPERATION 14 6 1 ADDRESSING...

Page 3: ...the safety precautions listed below A Read this manual carefully and keep manual near moving head B Follow the safety regulations mentioned in this manual when operating or installing this fixture C W...

Page 4: ...afe operation it is absolutely necessary for the user to follow the safety instructions and warning notes written in this user manual Important Damages caused by the disregard of this user manual are...

Page 5: ...it Only handle the power cord by the plug Never pull out the plug by tugging the power cord During the initial start up some or smell may arise This is a normal process and does not necessarily mean t...

Page 6: ...allation place is blocked when rigging un rigging or servicing the fixture Always fix the fixture with an appropriate safety rope Fix the safety rope at the correct fixation points only The safety rop...

Page 7: ...7 flashes per second Exact positioning within 4500 Pan and 2700 Tilt 8 DMX channels 16 bit Pan Tilt movement resolution 8 DMX channels 8 bit Pan Tilt movement resolution 3 digit LED display for start...

Page 8: ...00 Before replacing the lamp unplug mains lead and let the lamp cool down approx 10 minutes During the installation do not touch the glass bulbs bare handed Please follow the lamp manufacturer s notes...

Page 9: ...me until the light is evenly distributed If the light is brighter around the edge than it is in the center or if light output is low the lamp is too far back in the reflector Push the lamp out by turn...

Page 10: ...lculating working load limits installation material being used and periodic safety inspection of all installation material and the projector If you lack these qualifications do not attempt the install...

Page 11: ...ussing system etc insert the end in the carbine and tighten the fixation screws Use the safety rope exclusively as a closed ring Never use by only securing at each end The maximum drop distance must n...

Page 12: ...re with another Occupation of XLR connection If you are using controllers with this occupation you can connect the DMX output of the controller directly with the DMX input of the first fixture in the...

Page 13: ...s you first have to open the shutter control channel 4 DMX value 241 255 Turn the focus screw next to the objective lens for adjusting the focus in order to obtain a sharp projection 6 1 Addressing Ea...

Page 14: ...it mode via the Function DIP switches Controlling After having addressed all this moving head light you may now start operating these via your lighting controller Note After switching on the moving he...

Page 15: ...7fps dimmer Channel 5 Pan Movement within 450 Channel 6 Tilt movement within 270 Channel 7 lens control Channel 8 Auto focus control 6 3 Special settings Mode Function DIP switch no 1 2 3 4 5 6 Not oc...

Page 16: ...Further instructions depending on the installation spot and usage have to be handled by a skilled installer and any safety problems have to be removed DANGER TO LIFE Disconnect from mains before start...

Page 17: ...nel with a fitting screwdriver from the housing anticlockwise Step 2 Remove the old fuse from the fuse holder Step 3 Install the new fuse in the fuse holder Step 4 Replace the fuse holder in the housi...

Page 18: ...t EFFECTS 3 face Prism effect OPTICS Motorized focus DIMMER SHUTTER STROBE Linear dimmer Shutter Strobe 1 10 flashes per second PAN TILT Horizontal direction 450 scanning smooth scanning action and ac...

Page 19: ...lites com 19 POWER Magnetic Ballast 200 220 V 60 Hz 100 120 V 60 Hz optional 220 240 V 50 Hz optional POWER Power Consumption 400 W DIMENSION L 420 W 390 H 560 mm L 16 53 W 15 35 H 22 05 inches WEIGHT...

Page 20: ...color o Replace the lamp o Clean optics o Re home the fixture Unit is producing unexpected results o Check DMX starting address on the fixture and console match o Verify that the last fixture on the...