![Furuno TZT16F Installation Manual Download Page 55](http://html1.mh-extra.com/html/furuno/tzt16f/tzt16f_installation-manual_2350509055.webp)
3. HOW TO SET UP THE EQUIPMENT
3-17
*: This item is only available for DFF3 users.
When [Transducer Setup Type] is set to [Model] and connected to DFF3
When [Transducer Setup Type] is set to [Manual]
Motion sensor menu
Adjust these settings to view a clearer picture of the seabed, fish schools etc when in
moderate-to-rough seas.
Note 1:
For connection of NMEA 0183 equipment, ask your dealer to set up the equip-
ment.
Note 2:
To use the heaving function, the following settings are required at the satellite
compass. For the setting procedure, see the operator’s manual for your satellite com-
pass. Settings for SC-30 are done from the [IF-NMEASC] menu, settings for SC-50/
110 are done from the [DATA OUT] menu.
[Low Frequency Max] Display the low frequency maximum.*
[Reset Default Set-
tings]
Reset the Transducer Setup menu settings to default.
[OK], [Cancel]
Menu item
Description
Options
(setting range)
[High Frequency]
Select the model and frequency (HF & LF) of the connected
transducer from the appropriate drop down menu.
[Low Frequency]
Menu item
Description
Options
(setting range)
[High Frequency (KHz)]
Set the kHz frequency for high frequency. Setting ranges vary
depending on the transducer connected.
[Transducer Power HF]
Set the transmission power for high frequency.
Note 1:
This menu item is available only for
DFF1, DFF1-UHD, BBDS1 and internal fish
finder users.
Note 2:
For DDF1-UHD users, when the con-
nected transducer TDID is not supported by the
DFF1-UHD, the setting is fixed as [1000].
[600], [1000]
[Band Width (HF)]
Set the bandwidth for high frequency.
Note:
This item is only available for DFF3 users
when the Transducer type is set to [Manual].
[10] to [100]
[Low Frequency (KHz)]
Set the kHz frequency for low frequency. Setting ranges vary
depending on the transducer connected.
[Transducer Power LF]
Set the transmission power for low frequency.
Note 1:
This menu item is available only for
DFF1, DFF1-UHD, BBDS1 and internal fish
finder users.
Note 2:
For DDF1-UHD users, when the con-
nected transducer TDID is not supported by the
DFF1-UHD, the setting is fixed as [1000].
[600], [1000]
[Band Width (LF)]
Set the bandwidth for low frequency.
Note:
This item is only available for DFF3
users.
[10] to [100]
Menu item
Description
Options
(setting range)
Summary of Contents for TZT16F
Page 26: ...1 MOUNTING 1 18 This page is intentionally left blank...
Page 38: ...2 WIRING 2 12 This page is intentionally left blank...
Page 62: ...D 1 14 Jun 2019 H MAKI...
Page 63: ...14 Feb 2020 H MAKI D 2...
Page 64: ...D 3 14 Jun 2019 H MAKI...
Page 65: ...D 4 11 Nov 2019 H MAKI...