3. HOW TO SET UP THE EQUIPMENT
3-16
Transducer Setup menu
Note 1:
Make sure that the unit is set to stand-by when setting up the transducer.
Note 2:
When using with the DI-FFAMP, DO NOT set the [Model Number] menu if the
[Transducer Setup Type] menu is set to [Model]. This can cause damage to the trans-
ducer.Select [Transducer Setup Type] menu and select the model of connected trans-
ducer at [High Frequency] and [Low Frequency] menus.
Note 3:
When the DI-FFAMP is connected and [Transducer Setup Type] menu is set
to [Manual], the message “Power amplifier unit detected: In order to manually adjust
your transducer setup, please contact your Furuno dealer.” appears. Contact your
FURUNO dealer for setup.
[Fish Finder Demo
Mode]
Enable or disable the demonstration mode for the
sounder.
• [OFF]: Disable the demo mode.
• [Shallow]: Enable shallow water demo mode.
• [Deep]: Enable deep water demo mode.
Note:
For internal fish finder and DI-FFAMP users, the set-
tings are as follows:
[Off], [Demo1] to [Demo4].
[OFF], [Shallow],
[Deep]
[Set Hardware to
Factory Default]
Reset the external fish finder to its factory default settings. [OK], [Cancel]
[Restore Default
Settings]
Restore all menu settings to default.
[OK], [Cancel]
Menu item
Description
Options
(setting range)
[Transducer Setup
Type]
Select the type of transducer connected.
When the connected sounder is a DFF1-UHD and the
transducer has a compatible TDID, [TDID] is automati-
cally selected.
Note:
When the transducer model is changed or TDID is
detected, the frequency and bandwidth set on [Manual] is
to be reset.
• [Manual]: Manually set up the transducer.
• [Model]: Select the appropriate transducer model
(for FURUNO or AIRMAR transducers).
[Manual],
[Model]
[Model Number]
Select the appropriate model number from the list.
Note:
Only available when [Transducer Setup Type] is set to [Model].
[High Frequency Min]
Display the high frequency minimum.*
[High Frequency Max] Display the high frequency maximum.*
[Low Frequency Min]
Display the low frequency minimum.*
Menu item
Description
Options (setting
range)
DO NOT use this menu for selecting
the connected transducer.
DO NOT use this menu for selecting
the connected transducer.
Use this menu for selecting the
connected transducer.
Summary of Contents for TZT16F
Page 26: ...1 MOUNTING 1 18 This page is intentionally left blank...
Page 38: ...2 WIRING 2 12 This page is intentionally left blank...
Page 62: ...D 1 14 Jun 2019 H MAKI...
Page 63: ...14 Feb 2020 H MAKI D 2...
Page 64: ...D 3 14 Jun 2019 H MAKI...
Page 65: ...D 4 11 Nov 2019 H MAKI...