10. INSTALLATION
10-14
DATA 3 output setting
The DATA 3 can output NMEA 0183 (V1.5/V2.0) /IEC 61162-1 data or log pulse
depending on jumper block setting on the NAV board. For NMEA 0183
(V1.5/V2.0) /IEC 61162-1, the same signal of DATA 1 is output from DATA 3.
Selection of NMEA0183 or log pulse
Output data
NP board
NMEA 0183 (V1.5/
V2.0)/IEC 61162-1
(Default Setting)
Log pulse
JP3 #1-2 #2-3
JP4 #1-2 #2-3
JP10 #1-2 #2-3
Rate of log pulse output
150 mA Max.
50 VDC
Procedure for setting of log pulse rate
1) Press
ESC MENU
,
9
and
3
.
2) Press to select DATA 3. Log Pulse.
3) Press or to select log pulse for external equipment; 200ppm or
400ppm.
4) Press the
CU/NU ENT
key.
5) Press the
MENU ESC
key.