10. INSTALLATION
10-7
How to attach the N-P-8DFB connector
Outer Sheath
Armor
Inner Sheath Shield
Remove outer sheath and armor by the
dimensions shown left.
Expose inner sheath and shield by the
dimensions shown left.
Cut off insulator and core by 10mm.
Twist shield end.
Slip on clamp nut, gasket and clamp as
shown left.
Fold back shield over clamp and trim.
Cut aluminum foil at four places, 90
°
from one another.
Fold back aluminum foil onto shield and
trim.
Expose the insulator by 1mm.
Expose the core by 5mm.
Slip the pin onto the conductor. Solder
them together through the hole on the
pin.
Insert the shell into the pin. Screw the
clamp nut into the shell.
(Tighten by turning the clamp nut. Do
not tighten by turning the shell.)
Cover with heat-shrink tubing and heat.
30
10
Clamp
Nut
Gasket
(reddish
brown)
Clamp
Aluminum Foil
Trim shield here.
Trim aluminum
tape foil here.
Insulator
1
5
Clamp Nut
Pin
Shell
Solder through
the hole.
50
30
Summary of Contents for GP-150-Dual
Page 1: ...Dual GPS GP 150 DUAL OPERATOR S MANUAL www furuno co jp MODEL ...
Page 28: ...3 MARKS 3 4 This page is intentionally left blank ...
Page 36: ...4 NAVIGATION PLANNING 4 8 This page is intentionally left blank ...
Page 66: ...8 MENU SETTINGS 8 14 This page is intentionally left blank ...
Page 98: ...APPENDEX AP 4 World Time Standards ...
Page 117: ...D 1 ...
Page 118: ...D 2 ...
Page 119: ...D 3 ...
Page 120: ...Y Hatai hatai 2005 12 19 11 57 12 09 00 Dー4 ...
Page 121: ...Mar 27 07 R Esumi D 5 ...
Page 122: ...Feb 19 03 D 6 ...
Page 123: ...Feb 19 03 D 7 ...
Page 124: ...D 8 ...
Page 125: ...Jan 13 04 D 9 ...