Option #3 – Utilizing CAT5 Cable for NavNet Installations

Example of NavNet Installation Using CAT5 Cables and
Furuno 6-Pin Female-to- RJ45 Male Display Adapter Cables

This type of installation requires the use of Furuno Display Adapter Cables. It is possible
to create a NavNet that only uses display adapter cables if the hub is mounted very close
to the NavNet Displays and Network Sounder. It is also possible to “Mix” cabling Options
#2 and #3 to create a NavNet.

When longer cable runs are required, it will be necessary to utilize CAT5 Network Cable
for NavNet Installations. Utilizing CAT5 Cabling provides flexible installations and allows
a vessel to be pre-wired during construction or in preparation for a future NavNet
installation.

-Waterproof integrity of dealer supplied CAT5 Cabling and/or connections is NOT
guaranteed by Furuno and must be performed by the installer.

-Exact CAT5 Network Installation Methods and Practices are MANDATORY!  Please
see our “CAT5/RJ45 Installation Notes” below for help on this subject

All CAT5 Cables must be wired as “Straight” cables, because the connection will always
be made directly to the Ethernet Hub.  “Straight” CAT5 wiring information will be provided
in the “CAT5 Cable Installation Notes”.  Detailed information may also be found by using
our references in the Internet Resources section on page 8.

RJ-45M

RJ-45M

RJ-45M

RJ-45M

RJ-45M

RJ-45M

CAT5 Ethernet cable
(straight)

CAT5 Ethernet cable
(straight)

CAT5 Ethernet cable
(straight)

RJ45 INLINE COUPLERS
(RJ-45F to RJ-45F)

Network Sounder

(BBFF1)

RJ-45M

RJ-45M

CAT5 Ethernet cable
(straight)

Dealer Supplied CAT5 Cables, RJ45 Connectors & Ethernet Hub

Display Adapter Cable
P/N 000-144-601

RJ-45M

RJ-45M

RJ-45M

6F

6F

6F

6F

Connect RJ45M Directly to Hub

RJ-45M

Summary of Contents for GD-1700C

Page 1: ...n Section 2 The Three NavNet Cabling Options CAT5 RJ45 Information Section 3 NavNet Ethernet Hubs and Hub Power Supply Section 4 Easy 4 Step Software Installation Setting Procedures Section 5 Network...

Page 2: ...twork Components Any NavNet Display GPS Sensors Network Sounder BBFF1 Heading Sensors Smart Temp Depth Sensors RD30 Displays Any NavNet Radar Plotter or Plotter may be used independently as a stand al...

Page 3: ...the Furuno 6 Pin to 6 Pin Network Cables listed below is the simplest way to network any two NavNet Network components Please note that the Network Sounder is supplied with a standard 5 Meter Network...

Page 4: ...th cable from Table 3 1 Page 3 for EACH NavNet Display or Network Sounder Each cable must be routed to a suitable location where the Ethernet Hub will be mounted Note The Ethernet Hub Connection will...

Page 5: ...f dealer supplied CAT5 Cabling and or connections is NOT guaranteed by Furuno and must be performed by the installer Exact CAT5 Network Installation Methods and Practices are MANDATORY Please see our...

Page 6: ...ht connection for the RJ45 coupler junctions is the responsibility of the installer CAT5 Cable and RJ45 Connector Information While a complete explanation on installing CAT5 Network Cabling is beyond...

Page 7: ...Only Be Terminated With an RJ45 Connector NEVER use any other kind of connector or normal terminal strip for CAT5 cables The network will simply not function if this is done 110 Punch Down Blocks are...

Page 8: ...BROWN NOTE Identifying The Pin Assignment of an RJ45 Connector PIN 1 is at the LEFT when looking at the Flat Side of an RJ45 with the cable entry at the bottom 1 8 TOP FRONT 1 8 PIN 1 1 White w Orang...

Page 9: ...der of the network will still function Hubs will also protect the network from a Network Component that is placing bad data on the network or has timing problems Hubs also provide excellent feedback f...

Page 10: ...NMEA In GREEN NMEA Input SMART DEPTH SENSOR or OTHER PIN 5 12VDC RED 12VDC OUTPUT 250mA Maximum Current Out PIN 6 Buzzer Out BLACK Buzzer Output to Relay or Other PIN 7 GROUND SHIELD USE BARE SHIELD...

Page 11: ...technically any Ethernet 10BASE T or 10 100BASE T Hub is compatible with NavNet Products If you have a stable power source available any hub will work DANGER Do Not Attempt to Source More than 250mA f...

Page 12: ...nnected in a single network It is important that you confirm each individual radar is operational and adjusted properly before the network connections and settings are made Refer to the RADAR SETUP Se...

Page 13: ...this number is that the last three digits must be different from any other display in the NavNet network Usually this number only has to be changed if there are identical displays in the network RADAR...

Page 14: ...the other display s chart card slot 1 Both displays are configured to show the radar picture coming from the PORT RADAR 1 C MAP FURUNO and Navionics Chart information may be distributed through the ne...

Page 15: ...there are 3 displays and a network sounder Note that the RADAR SOURCE of the GD 1900C may be set to either the 1722C or the M1933C but not both GD 1900C 1722C M1933C DON T ALTER NETWORK SOUNDER SETUP...

Page 16: ...splay it will then be transmitted throughout the NavNet network via ethernet If you are using a GP 310B BBGPS and it is plugged into port 1 your NAV ports need to be changed from the default configura...

Page 17: ...ON SOURCE to the ALL Selection WARNING IF SUPPLYING POWER TO AN EXTERNAL NAVIGATOR FROM A NAVNET DISPLAY CURRENT DRAW MUST NOT EXCEED 250MA Refer to both the applicable NavNet installation manual and...

Page 18: ...e turn the backlighting illumination to the OFF position on the Sensor Mode GP36 when the display is hidden away and not viewed The GP36 may also be powered from a breaker in Sensor Mode for added red...

Page 19: ...keys Step 2 Move your curser to FURUNO GPS SENSOR then press the edit soft key and select NO with the curser control Step 3 Hit the RETURN soft key three times and then press NAV OPTIONS and NAV SOUR...

Page 20: ...tly to the DATA1 port on any NavNet display If the DATA1 port is occupied by the GP 310B you can use a Y Adapter Cable AIR 033 407 or a terminal strip to connect the Smart Sensor to any NavNet Display...

Page 21: ...he proper Temp and Depth Data to other NavNet Displays in the Network Follow the same procedure and turn on MTW and DPT at the NavNet Display that is connected to the Smart Sensor 1 2 3 4 5 6 7 WHITE...

Page 22: ...urce to DATA1 DATA3 7 Mono Color LCD And 10 CRT NavNet Displays Data4 10 4 Color LCD NavNet Displays 1 TD RS232 WHITE 2 RD RS232 BLUE 3 RD A Input YELLOW 4 RD B Input GREEN 5 12V DC RED 6 Buzzer Out B...

Page 23: ...and Temperature Sources to ETR in the General Setup Menu NOTE The NavNet Display s Depth and Temperature Alarm Parameters will always utilize the source of digital depth and temperature selected in t...

Page 24: ...tallation Manual for details When finished configuring the radar settings turn the display off then on again to escape from the INSTALLATION MODE STEP 2 Change Nav Position Source to BBGPS Keystroke S...

Reviews: