3. ADJUSTMENTS
3-6
2. Confirm that the “3.3V” and “UP” LEDs on the control box are on.
3. Remove the control box cover and check the terminal voltage as shown in the fol-
lowing table.
4. Set the
TEST/NORMAL
switch on the control panel to [TEST], then press the
DOWN
switch to confirm that the transducer lowers. Also, while the transducer is
being lowered, check that the “HTX” LED lights when the TX limit switch is passed
by the transducer shaft.
Note:
The TX limit switch does not stop the transducer when the
TEST/NORMAL
switch is in the [TEST] position.
5. Release the
DOWN
switch during lowering to confirm that the transducer stops
lowering.
Control panel
OFF
TEST
NORMAL
L.SW
UP
UP
HTX LTX DN
DOWN
LTX
Not used.
3.3V 220V
㼀㻮㻝
Terminal block Terminal No.
Voltage
TB1
(1) - (2)
(2) - (3)
(1) - (3)
220 VAC
220 VAC
220 VAC
Summary of Contents for FSV-75
Page 50: ...1 MOUNTING 1 42 This page is intentionally left blank ...
Page 118: ...D 1 6 Mar 2019 H MAKI ...
Page 119: ...D 2 22 Aug 2018 H MAKI ...
Page 120: ...D 3 22 Aug 2018 H MAKI ...
Page 121: ...D 4 5 Dec 2018 H MAKI ...
Page 122: ...D 5 5 Dec 2018 H MAKI ...
Page 123: ...D 6 16 Apr 2019 H MAKi ...
Page 124: ...D 7 16 Apr 2019 H MAKI ...
Page 125: ...D 8 16 Apr 2019 H MAKI ...
Page 126: ...D 9 16 Apr 2019 H MAKI ...
Page 127: ...D 10 9 Oct 2018 H MAKI ...
Page 128: ...D 11 22 Apr 2019 H MAKI ...
Page 129: ...D 12 9 Oct 2018 H MAKI ...
Page 130: ...D 13 9 Oct 2018 H MAKI ...
Page 131: ...D 14 6 Mar 2019 H MAKI ...
Page 132: ...D 15 19 Nov 2018 H MAKI ...
Page 133: ...D 16 8 Jan 2019 H MAKI ...