1. MOUNTING
1-12
At factory default, the distance to the transmitting position is 450 mm (tank length:
1000 mm (800 mm travel) or 1300 mm (1100 mm travel)). To adjust the distance to
the transmitting position, unfasten the two mounting screws (M6) to remount the TX
limit switch.
1.2.9
How to adjust the bow mark direction on the transducer
When you cannot face the bow mark on the hull unit flange to the bow direction due
to installation space, rotate the transducer so that the bow mark on the transducer
points toward the ship’s bow.
1. Release the transducer cable from the three cable clamps.
TX limit
switch
TX limit switch
(factory default position)
Detailed view: TX limit switch
Mounting
screw (M6,
2 pcs)
25 mm:
Screw holes for mounting
TX limit
switch are prepared
at 25 mm intervals. You can
raise the
TX limit
switch
position max 100 mm .
Cable clamp
Cable clamp
Summary of Contents for FSV-75
Page 50: ...1 MOUNTING 1 42 This page is intentionally left blank ...
Page 118: ...D 1 6 Mar 2019 H MAKI ...
Page 119: ...D 2 22 Aug 2018 H MAKI ...
Page 120: ...D 3 22 Aug 2018 H MAKI ...
Page 121: ...D 4 5 Dec 2018 H MAKI ...
Page 122: ...D 5 5 Dec 2018 H MAKI ...
Page 123: ...D 6 16 Apr 2019 H MAKi ...
Page 124: ...D 7 16 Apr 2019 H MAKI ...
Page 125: ...D 8 16 Apr 2019 H MAKI ...
Page 126: ...D 9 16 Apr 2019 H MAKI ...
Page 127: ...D 10 9 Oct 2018 H MAKI ...
Page 128: ...D 11 22 Apr 2019 H MAKI ...
Page 129: ...D 12 9 Oct 2018 H MAKI ...
Page 130: ...D 13 9 Oct 2018 H MAKI ...
Page 131: ...D 14 6 Mar 2019 H MAKI ...
Page 132: ...D 15 19 Nov 2018 H MAKI ...
Page 133: ...D 16 8 Jan 2019 H MAKI ...