1. MOUNTING
1-20
Disconnection/short circuit check
When one or more of the following errors occur, perform a disconnection/short circuit
check for the resolver or motor.
• Disconnection/short circuit check for the motor
Remove the terminal block 734-209-FUR from the TB1 (HFLT board) in the control
box, then measure resistance using a multimeter.
• Disconnection/short circuit check for the resolver
Remove the terminal block 733-106-FUR and 733-110-FUR from the TB8 and TB10
in the control box, then measure resistance using a multimeter.
Occurred error
Check point
9 Motor Test Error (Tilt)
Perform a disconnection/short circuit check for the
motor.
10 Motor Driver Error (Rotate)
11 Motor Driver Error (Tilt)
16 Motor Test Error (Rotate)
14 Resolver Test Error (Rotate) Perform a disconnection/short circuit check for the re-
solver.
15 Resolver Test Error (Tilt)
1 2 3 4 5 6 7 8 9
䚷
Terminal block 734-209-FUR
Rotation motor
Tilt motor
Coil
Coil
Coil
Coil
Correct value
Measured point
If the measured value is not correct value...
1-2, 3-4
6-7, 8-9
1-3
6-8
Between ground
point (hull unit
chassis) and pins 1
thru 4, 6 thru 9
10
㻌㼠㼛㻌
30 Ω
10
㻌㼠㼛㻌
30 Ω
∞
∞
∞
Rotation motor or motor cable error
Tilt motor or motor cable error
Insulation failure in the rotation motor or motor
cable.
Insulation failure in the tilt motor or motor
cable.
Insulation failure in the motor or motor cable.
Correct value
Measured point
If the measured value is not correct value...
1-2
3-5, 4-6
3-4
Between ground
point (hull unit
chassis) and pins 1
thru 6
50 to 70Ω
100 to 130Ω
∞
∞
1 2 3 4 5 6
Terminal block 733-106-FUR
Excitation
coil
Output coil
Output coil
Rotation resolver
Rotation resolver or resolver cable error
When the extension box is used:
Insulation failure in the extension box
Correct value
Measured point
If the measured value is not correct value...
1-2
3-5, 4-6
3-4
50 to 70 Ω
100 to 130 Ω
∞
∞
Terminal block 733-110-FUR
Tilt resolver or resolver cable error
When the extension box is used:
Insulation failure in the extension box
1 2 3 4 5 6 7 8 9 10
䚷
Excitation
coil
Output coil
Output coil
Tilt resolver
Between ground
point (hull unit
chassis) and pins 1
thru 6
Summary of Contents for FSV-75
Page 50: ...1 MOUNTING 1 42 This page is intentionally left blank ...
Page 118: ...D 1 6 Mar 2019 H MAKI ...
Page 119: ...D 2 22 Aug 2018 H MAKI ...
Page 120: ...D 3 22 Aug 2018 H MAKI ...
Page 121: ...D 4 5 Dec 2018 H MAKI ...
Page 122: ...D 5 5 Dec 2018 H MAKI ...
Page 123: ...D 6 16 Apr 2019 H MAKi ...
Page 124: ...D 7 16 Apr 2019 H MAKI ...
Page 125: ...D 8 16 Apr 2019 H MAKI ...
Page 126: ...D 9 16 Apr 2019 H MAKI ...
Page 127: ...D 10 9 Oct 2018 H MAKI ...
Page 128: ...D 11 22 Apr 2019 H MAKI ...
Page 129: ...D 12 9 Oct 2018 H MAKI ...
Page 130: ...D 13 9 Oct 2018 H MAKI ...
Page 131: ...D 14 6 Mar 2019 H MAKI ...
Page 132: ...D 15 19 Nov 2018 H MAKI ...
Page 133: ...D 16 8 Jan 2019 H MAKI ...