SP - 2
(4) Range Scales and Ring Intervals
0.125, 0.25, 0.5, 0.75, 1, 1.5, 2, 3, 4, 6, 8, 12, 16, 24, 32, 48, 96
0.025, 0.05, 0.1, 0.25, 0.2, 0.25, 0.5, 0.5, 1, 1, 2, 2, 4, 8, 8, 12, 12
(5) Range Accuracy
1% of range in use or 15 m whichever is the greater
(6) Range Discrimination
25 m
(7) Bearing
Accuracy
±1°
(8) Bearing
Discrimination 2.5°
(9) Presentation modes
Head-up, Head-up TB, North-up, Course-up, True Motion North-up
(Heading signal required except for HU)
(10) Variable Range Markers Two Variable Range Markers, switched
(11) Offcenter
Sweep origin can be offcentered by 50% of range in use in any direction
(Not available for maximum range)
(12) Guard Zone
Anywhere above 0.7 SM
(13) Electronic Plotting Aids (EPA)
10 Targets Providing Range, Bearing, Course, Speed, CPA and TCPA
Note: EPA disabled when ARPA function is used.
(14) Parallel Index Lines
2, 3 and 6 lines (selectable on menu)
4. INTERFACE
(1) Gyrocompass
Built-in interface accepts synchronized signal (20-50 V, 50-400 Hz)
(2) Speed Log
Built-in interface accepts contact closure or DC signal at 200, 400 or 500
pulses/sm.
(3) External Radar (option)
Built-in interswitch for 2 channels provided
5. POWER SUPPLY
(1) DC Source
24-32 VDC: 10.8-8.2 A, 260VA
(2) AC Source
100-115/220-230 VAC: 4.1 A, 1 phase, 50-60 Hz, 410 VA
6. ENVIRONMENTAL CONDITION
(1) Ambient Temperature (Complies with IEC60945)
Display Unit:
-15°C to +40°C
Antenna Unit:
-25°C to +70°C
(2) Relative Humidity
95% at 40°C
(3) Water proofing
Display Unit (Panel): IPX2
Antenna Unit: IPX6
(4) Vibration
±1 mm ±10%, 2(5) to 13.2 Hz,
Maximum acceleration 7 m/s
2