2. WIRING
16
10. Connect the harness plug 7P to the socket J7 on the PWR board and the harness
plug 16P to the socket J8. Fix the wire from connector J7 with a locking wire sad-
dle in the unit.
11. Adjust the cable length inside the interface unit, set the seal nut to the cable, then
tighten the seal nut.
12. Close the inner case and outside cover of the interface unit.
13. Close the cover of the processor unit.
14. The connections for telesounder are different by models. Connect them to the in-
terface unit referring to the interconnection diagram at the back of this manual.
J8
CTRL
B16B-PH-SM4
02P6392
J7 B7B-XH-A
PWR
02P6391
CN-13
Interface unit
Connection for PWR/CTRL board
PWR board
Locking wire
saddle
J7
CTRL board
Summary of Contents for FCV-1900