background image

D-4

Y. Hatai

Summary of Contents for FCR-2829W

Page 1: ...ransceiver Unit 2 9 2 4 Radar Processor Unit 2 14 2 5 Processor Unit 2 18 2 6 Monitor Unit 2 29 2 7 Sensor Adapters option 2 30 2 8 Intelligent HUB HUB 3000 option 2 49 2 9 How to Extend the Control Unit Cable option 2 50 3 SETTING AND ADJUSTMENTS 3 1 3 1 How to Access the Radar Installation Menu 3 1 3 2 How to Align the Heading 3 1 3 3 How to Adjust the Sweep Timing 3 2 3 4 How to Suppress Main B...

Page 2: ... elemental chlorine free FURUNO Authorized Distributor Dealer 9 52 Ashihara cho Nishinomiya 662 8580 JAPAN A JUN 2012 Printed in Japan All rights reserved G1 JAN 05 2017 Pub No IME 36100 G1 REFU FCR 2829W 2839SW 0 0 0 1 7 6 1 3 9 1 6 ...

Page 3: ...enna emits electromagnetic radio frequency RF energy which can be harmful particularly to your eyes Never look directly into the antenna aperture from a close distance while the radar is in operation or expose yourself to the transmitting antenna at a close distance Distances at which RF radiation levels of 100 50 and 10 W m are given in the table below Note If the antenna unit is installed at a c...

Page 4: ...in a dusty environment Water in the units can result in fire electrical shock or damage the equipment Attach protective earth securely to the ship s body The protective earth grounding is required for the AC power supply to prevent electrical shock CAUTION Observe the following compass safe distances to prevent deviation of a magnetic compass Antenna Unit FCR 2829W Standard compass Steering compas...

Page 5: ...t BR 001 002 EC 3000 PROCESSOR UNIT Serial 1 2 IEC 61162 2 Gyrocompass1 AIS Serial 3 8 IEC 61162 1 EPFS2 navigator SDME3 Speed Log Echo sounder Wind Alarm Navtex etc Digital Out 1 6 1 System Fail 2 Power Fail 3 Normal Close 1 4 Normal Close 2 5 Normal Open 1 6 Normal Open 2 Dashed lines indicate optional or local supply equipment Sensor Adapter or Switching HUB HB 100 Radar Control Unit RCU 025 OR...

Page 6: ...e for the ship s rate of turn Gyrocompass must have update rate better than 40 Hz HSC or 20 Hz other than HSC 2 Connect the EPFS which is approved in accordance with the requirements of the IMO in resolution MSC 112 73 is used 2 Connect the EPFS which is approved in accordance with the requirements of the IMO in resolution MSC 112 73 is used The GPS speed may not meet IMO requirements unless type ...

Page 7: ...hing HUB HUB 100 Radar Control Unit RCU 025 OR Trackball Control Unit RCU 026 ECDIS Control Unit RCU 024 OR Radar Control Unit RCU 025 OR Trackball Control Unit RCU 026 Monitor Unit MU 231 Digital In ACK IN VDR Intelligent Hub HUB 3000 100 115 220 230 VAC 1ø 50 60 Hz JB 1 Use the gyrocompass having an update rate that is adequate for the ship s rate of turn Gyrocompass must have update rate better...

Page 8: ...1 CP03 35040 000 021 356 15 m cable RW 9600 w CP03 35002 CP03 35050 000 021 357 30 m cable RW 9600 w CP03 35002 CP03 35060 000 021 358 40 m cable RW 9600 w CP03 35002 CP03 35070 000 021 359 50 m cable RW 9600 w CP03 35002 CP03 27501 008 540 200 1 For RTR 081A CP03 25602 008 535 940 1 For RPU 013 CP24 02100 000 020 557 1 For EC 3000 CP24 02301 001 170 910 1 For RCU 026 CP24 02201 001 170 810 1 For ...

Page 9: ...40 000 021 356 15 m cable RW 9600 w CP03 35002 CP03 35050 000 021 357 30 m cable RW 9600 w CP03 35002 CP03 35060 000 021 358 40 m cable RW 9600 w CP03 35002 CP03 35070 000 021 359 50 m cable RW 9600 w CP03 35002 CP03 27601 008 540 570 1 For RTR 082 CP03 25602 008 535 940 1 For RPU 013 AC set CP24 02100 000 020 557 1 For EC 3000 CP24 02201 001 170 810 1 For RCU 025 CP24 02301 001 170 910 1 For RCU ...

Page 10: ... for IMO radar 2839SW PM 31 000 080 438 Mandatory for IMO radar 2829W Control Unir RCU 025 Radar standard type RCU 026 Trackball type RCU 024 ECDIS standard type Transformer Unit RU 1803 Converts 440 VAC to 100 VAC for pro cessor unit RU 3305 Converts 110 115 220 230 VAC to 100 VAC for de icer RU 5693 Converts 110 VAC to 220 VAC for transceiver unit 2839SW RU 6522 Converts 220 VAC to 200 VAC for t...

Page 11: ...iver Angled 210 258J 000 148 885 10 For WAGO connectors Case Gasket OP24 28 001 169 970 For MC 3000S OP24 29 001 169 960 For MC 3010A 3020D 3030D IPX2 Kit OP24 23 001 171 780 For EC 3000 Flush Mount OP24 27 001 171 820 For RCU 026 Waveguide Twist RWA 1050 C 109 310 100 180 10 Rectangular Guide Clamp OP03 148 008 477 540 Control Unit Replace ment Kit OP24 31 001 181 700 For RCU 024 025 FR 9 Termina...

Page 12: ...TPSH XH12X2 L30SP2 001 186 340 10 For RCU 026 30 m DSUB9P X2 L5M 001 188 260 For MU 190 231 brill control 5 m DSUB9P X2 L10M 001 188 270 For MU 190 231 brill control 10 m DSUB9P X2 L5M WP 000 177 053 10 For monitor unit 5 m waterproofing type DSUB9P X2 L10M WP 000 177 247 10 For monitor unit 5 m waterproofing type OP24 32 001 188 300 USB cable 5 m w EMI core DVI BNCX5 L2000 001 204 150 For VDR con...

Page 13: ...icker which is pre attached on the radar processor unit according to your radars specification Refer to the table shown below to confirm your category Category Radar type ANT rotation speed CAT 1C FCR 2819 FCR 2829 FCR 2839S FCR 2829W FCR 2839SW Normal speed CAT 1HC FCR 2819 FCR 2829 FCR 2839S HSC CAT 2C FCR 2119 BB FCR 2129 BB FCR 2139S BB Normal speed CAT 2HC FCR 2119 BB FCR 2129 BB FCR 2139S BB...

Page 14: ...EQUIPMENT LISTS xii This page is intentionally left blank ...

Page 15: ...mum No blind sector should exist in arc of the horizon from ahead to 22 5 aft of the beam to either side see Figure 1 below Also individual blind sec tors of more than 5 or the total arc of both blind sectors of more than 20 should not occur in the remaining arc Figure 2 Note that any two blind sectors separated by 3 or less are regarded as one sector NOTICE Do not apply paint anti corrosive seala...

Page 16: ...the compass safe distances on page ii to prevent de viation of the magnetic compass Do not paint the radiator aperture to ensure proper emission of the radar waves The antenna base is made of cast aluminium To prevent electrolytic corrosion of the antenna base use the seal washers and corrosion proof rubber mat ground the unit with the ground wire supplied Deposits and fumes from a funnel or other...

Page 17: ... of the radiator flange 6 Set the antenna radiator to the radiator bracket 7 Coat hex bolts M8x40 with anticorrosive sealant and use them to loosely fasten the antenna radiator to the antenna unit chassis 8 Remove two guide pins inserted at step 1 and then tighten fixing bolts Hole for a guide pin 5 mm Anticorrosive sealant Hole for a guide pin Waveguide cap 10 mm O ring CAUTION Be sure to remove ...

Page 18: ... with silicone sealant as shown in the illustration below Coating the waveguide flange with silicone sealant Antenna radiator Waveguide Radiator bracket Hex bolt M8x40 8 pcs O ring Apply silicone sealant here O ring Choke groove O ring Apply silicone sealant here Evenly coat the waveguide flange with silicone sealant Apply sealant sparingly it leaks out slightly when the fixing bolts are tightened...

Page 19: ...r mat supplied on the mounting platform 4 Place the antenna unit on the rubber mat orienting the unit so the antenna switch on it faces the ship s bow Antenna unit front view 5 Fasten the antenna unit to the mounting platform with M12x60 hex bolts nuts flat washers and seal washers NOTICE NO To hoist antenna unit aboard vessel attach ropes to lifting fixtures and hoist unit with crane To remove lo...

Page 20: ...e RW 4747 340 mm supplied between the grounding point and ground terminal on the antenna unit Coat the entire ground system How to mount the antenna unit Anticorrosive sealant Seal washer Rubber mat Anticorrosive sealant Groundwire Hexbolt Springwasher Anticorrosive sealant Springwasher Hexnut OR Groundwire Hexnut Springwasher Flatwasher Hexboltweldedto ship ssuperstructure Anticorrosivesealant Gr...

Page 21: ...the radiator To prevent this relocate the antenna unit or if relocation is not possible reinforce the platform Mounting of S band antenna unit Antenna unit assembling The antenna radiator and the antenna housing are shipped in separate packages As semble them as below The antenna unit may be assembled before hoisting it to the mounting platform However do not lift the antenna unit by the radiator ...

Page 22: ...n the bracket If reversely oriented the radiator cannot be set to the bracket 5 Loosely fix the radiator to the radiator bracket with hex bolts M10x25 spring washers and flat washers 6 Remove the guides pins and tighten hex bolts Assembling the radiator bracket Do not remove the teflon tube from the center conductor O ring grooves Radiator front Guide pin 2 pcs Arrow mark for the radiator front CA...

Page 23: ... arrange the ropes A and B Attachment of lifting fixtures collar and ropes Lifting fixture Collar for fixing Supplied as installation materials Remove afterinstallation Hex bolt M12x20 Spring washer M12 Remove lifting fixture coat threadsof hex bolts with silicone grease andthen insert bolts in antenna chassis Lifting hook 2 pcs A 2m B 1 8m Protect radiator with cardboard or cloth at locations mar...

Page 24: ...Hoist the antenna unit as shown on page 1 9 and place it on the rubber mat Orient the cable gland toward the ship s stern or port starboard Remove the lifting fix tures and collars 4 Fix the antenna base to the mounting platform with four M12x70 hex bolts nuts washers and seal washers supplied 5 Arrange the grounding terminal at the nearest grounding spot with the M6x25 hex bolt nut and washers su...

Page 25: ...sed hardware with silicone sealant Coat with silicone sealant afterastening ground wire Ground wire Antenna chassis Ground terminal provided on antenna base Hex bolt Flat washer Flat washer Spring washer Hex nut Ground wire Coat with silicone sealant OR Hex nut Spring washer Flat washer Hex bolt Ground wire Welding Arrange ground terminal as close as possible to antenna unit ...

Page 26: ...rces because of heat that can build up inside the cabinet Locate the equipment away from places subject to water splash and rain Leave sufficient space at the sides and rear of the unit to facilitate maintenance Determine the mounting location considering the length of the signal cable between the control unit and the processor unit A magnetic compass will be affected if the control unit is placed...

Page 27: ...iew of control units Fixing without KB fixing metal 1 Drill four mounting holes of 5 mm diameter referring to the outline drawing at the back of this manual 2 Fix the control unit with four screws M4 from under side of the desktop The M4 screws with a sufficient length for the thickness of the desktop should be provided locally Control Unit RCU 025 Control unit RCU 026 KB fixing metal RCU 026 RCU ...

Page 28: ... control unit to the cutout 3 Attach the mounting plate to the control unit with four screws from the rear side 4 Screw the wing screw to each mounting plate and then insert hex bolt to each wing screw 5 Fasten each wing screw and then fasten the hex nuts as shown in figure below Side view of control units Control Unit Type Code RCU 025 OP24 24 001 171 790 RCU 026 OP24 27 001 171 820 388 2 110 2 1...

Page 29: ...facilitate maintenance A magnetic compass will be affected if he processor unit is placed too close to the magnetic compass Observe the compass safe distances on page ii to prevent de viation of a magnetic compass 1 4 2 Mounting procedure 1 Fix the unit with four M6 bolts or self tapping screws Floor mounting or bulkhead mounting Note If you fix the unit cable entry upside never remove the screw M...

Page 30: ...ides and rear of the unit to facilitate maintenance Make sure that the ground wire is connected between the earth terminal on the chassis and the ship s earth A magnetic compass will be affected if the processor unit is placed too close to the magnetic compass Observe the compass safe distances on page ii to prevent com pass malfunction Do not remove the dummy plate to prevent the wrong operation ...

Page 31: ... so that the notches on it are facing the deck 2 Use six bolts M6 local supply to fix the processor unit For bulkhead mounting screw three bolts for the lower bolt holes leaving 5 mm of thread exposed from the bolt head Set the notches of the processor unit on the three bolts then screw three bolts for the upper bolt holes Then secure the pro cessor unit in place with all six bolts fastened tightl...

Page 32: ...g netic compass Observe the compass safe distances at the front of this manual to prevent interference to a magnetic compass Select the mounting location considering the numbers of the sensor adapters con nected Maximum eight MC 3000S can be connected to a sensor network Maximum 10 sensor adapters MC 3010A 3020D 3030D can be connected to a MC 3000S However note that five MC 3010A can be connected ...

Page 33: ...pment away from places subject to water splash and rain Make sure that the ground wire is connected between the earth terminal on chassis and the ship s earth Leave sufficient space at the sides and rear of the unit to facilitate maintenance A magnetic compass will be affected if the adapter is placed too close to the mag netic compass Observe the compass safe distances at the front of this manual...

Page 34: ...en you select a mounting location keep in mind the following points Locate the adapter away from heat sources because of heat that can build up inside the cabinet The vibration should be minimal Locate the equipment away from places subject to water splash and rain Make sure that the ground wire is connected between the earth terminal on chassis and the ship s earth Leave sufficient space at the s...

Page 35: ...VAC RW 9600 15 30 40 50 m Max 100 m DPYC 2 5 Junction Box RJB 001 Junction Box RJB 001 Cable requires fabrication If the cable run between the antenna unit and radar processor unit is more than 100m use Junction box RJB 001 However the maximum length is 300m DSUB9P X2 cable 5 m 10 m Processor Unit EC 3000 MPYC 7 or TTYC 1T Radar Control Unit RCU 025 Trackball Control Unit RCU 026 100 230 VAC 100 2...

Page 36: ...ween the antenna unit and radar processor unit is more than 100m use Junction box RJB 001 However the maximum length is 300m DSUB9P DSUB9P cable 5 m 10 m Processor Unit EC 3000 MPYC 7 Radar Control Unit RCU 025 Trackball Control Unit RCU 026 100 230 VAC 100 230 VAC DVI D D SINGLE LINK cable or RGB HD15 5 m 10 m Monitor Unit MU 231 FCR 28x9 USB memory P5E 4PTX BL cable GYRO SYNCHRO STEPPER or IEC61...

Page 37: ...ision of the DVI or ERGB cables is necessary use the dividers shown below DVI cable divider DVI 12A maker INAGICS RGB divider CIF 12H DD 106 or WBD 14F maker INAGENICS Make sure that the ground wires are connected between the ground terminals on each equipment and the ship s earth Pass the cables through the specified clamp or the locking wire saddle If a UPS user supply is connected to this equip...

Page 38: ...unit The signal cable entrance cable gland is located directly below the waveguide outlet If the waveguide is installed downward from the waveguide outlet position using an E bend waveguide you may not be able to insert the signal cable into the cable gland To avoid this inconvenience shift the waveguide run left or right using an H bend waveguide as shown below The E bend and H bend waveguides ar...

Page 39: ...up to 55 C 2 2 2 FCR 2839SW The signal cable MPYCY 12 Japan Industrial Standard cable or equivalent power cable TPYCY 2 5 Japan Industrial Standard cable or equivalent and microwave co axial cable LHPX 20 ASSY are used between the antenna unit and transceiver unit 1 Remove the right hand side cover viewing from the bow from the antenna unit by unscrewing ten bolts 13 mm 2 Unfasten the clamping gla...

Page 40: ...rminal board TB803 and then connect cores to TB803 by using the terminal opener 9 Reattach the antenna cover and then cover the gland junction with putty for wa terproofing Flat washer 5 mm Vinyl sheath Clamping gland Gasket 5 mm Trim the armor with width of washer 5 mm Wiring for WAGO connector Press downward Terminal opener WAGO Connector Wire Twist Procedure 1 Twist the cores 2 Press the termin...

Page 41: ...e in below 5 Fold back the armor by 5 mm and then put it between washers 6 Run the power cable behind of the terminal board and then fix it with the clamp 7 Determine the length of the cores considering their location on the terminal board TB902 and then connect cores to TB902 by using the terminal opener 8 Reattach the antenna cover 9 Cover the gland junction with putty for waterproofing Vinyl sh...

Page 42: ...t bolts M6x20 to remove the flange cover from the antenna unit 2 Apply grease to the O ring located in the flange 3 Coat between mating surfaces of the coupler at the end of the coaxial cable and waveguide flange as below with waterproofing compound supplied with installa tion materials Do not coat the O ring 4 Screw eight bolt unfastened at step 1 to fix the coupler to the flange Lying of microwa...

Page 43: ...l cable to the TB802 on TB Board and fix the shield with cable clamp 30 5 Approx 250 Armor Shield Unit mm Vinyl sheath Fold back the shield 6 14 5 9 Conductor Fold back outer conductor Coaxial cable Shield 30 mm CAUTION Wiring for WAGO connector Press downward Terminal opener Wire WAGO connector Twist Procedures 1 Twist the conductor 2 Press the terminal opener downward 3 Insert the wire to hole 4...

Page 44: ...h the cable entrance of the RTR 081 and then fix the ar mors with the cable clamp 3 Connect each core to TB801 TB802 TB803 and TB804 referring to the intercon nection diagram 4 Connect the grounding wire shipyard supply between the ground terminal be hind the cable clamp and the grounding point Vinyl sheath Approx 250 30 5 Armor Vinyl Sheath 6 Do not remove this film TB801 TB803 TB804 TB802 TB Boa...

Page 45: ...t frequency and waveform are left unobstructed With a waveguide and magnetron however mismatch of impedance causes fre quency pulling For this reason the number of possible mismatches in a waveguide run i e joins and bends must be kept minimum Each pair of flanges should be coupled with one O ring four bolts and spring wash ers and the choke flange must be in the upper position The bolts and O rin...

Page 46: ...rcuit Fabricating of TPYCY 2 5 1 Fabricate the cable as below 2 Fix the crimp on lug FV5 5 4 yellow to each conductor Wiring 1 Remove the cover from the RTR 082 2 Pass the cables through the cable entrance and then fix the armor with the cable clamp Vinyl sheath Approx 250 30 5 Armor Vinyl Sheath 6 Vinyl sheath Approx 170 mm 30 mm 5 mm FV5 5 4 Armor Sheath ...

Page 47: ... coaxial cable Connect the coaxial cable to the transceiver unit as below 1 Loosen eight bolts M6x20 to remove the dust cover from the output WG adapter 2 Fasten eight bolts removed at step 1 to attach the flange to the transceiver unit 3 Attach the coaxial cable to the converter of the flange TB802 TB803 TB801 TB911 TB912 M6x20 8 pcs Circulator Adapter Output WG adapter Coaxial cable Converter M6...

Page 48: ...elow For the power cable use DPYC 2 5 Japan Industry Stan dard Cable or the equivalent Note For AC Pass the AC line through a double contact breaker shipyard supply Fabricating the power cable 1 Cut armor of the cable by 40 mm 2 Cut vinyl sheath by 35 mm 3 Remove insulation of wires by about 10 mm Fix crimp on lugs to the cores 4 Peel paint of the armor by 40 mm 5 Cover the end of armor with vinyl...

Page 49: ...9342 Processor unit Location of connectors F1 1 2 ACK f18 9 AIS 1 7 AD100 8 GYRO 28 PSU004 24 f7 4 VDR IN f7 VDROUT 24 26 9 14 17 15 DC AC 21 f9 HDG 3 2 5 4 6 RSD 19 18 20 Network Power cable clamp Power cable terminal board Remove the protection cover Heading senor Power control cable Gyrocompass AD 100 Antenna unit Cable clamp GND TERMINAL Power cable FUSE F70 ...

Page 50: ...6 PSU J654 J615 J614 J613 Tx HV line J609 Cable clamp 03P9342 Gyro converter board or AD 100 Heading sensor Cable from antenna unit Coaxial cable Gyro converter board To Sub display To Sub display SEMI LOG FULL LOG J611 Power control cable to EC 3000 Do not use this connector to input the radar video ...

Page 51: ...Coaxial cable 14 Fold back shield Wiring for Coaxial cable CAUTION Clamp shied with bracket Tighten conductor with screw Procedures 1 Twist the conductor 2 Press the terminal opener downward 3 Insert the wire to hole 4 Remove the terminal opener 5 Pull the wire to confirm that it is ecure Terminal opener Wiring for WAGO connector WAGO connector Wire Twist Press downward Do not use crimp on lug to ...

Page 52: ...ate Tighten the fixing screws on these connectors to pre vent disconnection from the processor unit Note Connect the cables so that they do not interfere with the opening or closing of the DVD tray Port Connector Conventional remote display FCR 2107 series radar J617 FULL LOG Overall gain Even if input video level is ad justed to 4 Vp p the gain is 8 dB lower than that on the master ra dar The gai...

Page 53: ...t to hide LED and switches MU 190 231 DVI1 DVI D D S LINK cable COM1 DSUB9P X2 L cable COM1 MU 190 231 DVI3 DVI D D S LINK cable or DVI BNCX5 L2000 cable COM2 DSUB9P X2 L cable DVI3 USB1 RCU 024 026 TS 20 071 1 cable USB2 3 Optional control unit RCU 024 026 TS 20 071 1 cable HUB 3000 DTI C5E350 VCV cable LAN1 LAN2 HUB 100 MC 3000S FR FTPC CY cable within 50m DVI1 COM2 Cable clamp See the next page...

Page 54: ...HT BLU 5 GRN 6 WHT BRN 7 BRN 8 Cross cable Straight cable Using special crimping tool MPT5 8AS PANDUIT CORP crimp the modular plug Finally check the plug visually Expose inner vinyl sheath Remove the outer sheath by approx 25 mm Be careful not to damage inner shield and cores Fold back the shield wrap it onto the outer sheath and cut it leaving 9 mm 1 2 3 25 mm approx 9 mm 4 5 6 approx 9 mm approx...

Page 55: ... the position shown below by using four screws preattached to the proces sor unit Name Type Code No Qty Remarks Binding Screw 4 40UNCX3 16 000 176 619 10 10 Connector Gasket 1 24 014 0107 100 367 730 10 2 For D sub connectors Connector Gasket 2 24 014 0108 100 367 741 10 3 For DVI connectors Rainproof Cover 24 014 0109 100 372 202 10 1 Gasket Clamping Plate 24 014 0114 100 372 210 10 2 For D sub c...

Page 56: ... TTYCSLA 1Q TTYCS 10 TTYCSLA 10 400 380 Cable type JIS Fabrication of TTYCS series Fabrication of TTYCSLA series L Sheath Clamp here by cable clamp Vinyl tape 6 30 Drain wire 100 5 Pass the vinyl sheath local supply onto the drain wire then attach the crimp on lug preattached to the earth clamp on the processor unit to it Cable tie supplied Cable tie supplied Processor unit cover removed Crimp on ...

Page 57: ...he cables through the clamp holes then fasten the bolts removed at step 2 to fix the cables Loosen these three bolts to remove the upper plate Loosen this bolt to use the lower clamp holes Loosen this bolt to use the lower clamp holes Clamp holes upper Clamp holes lower J4 J4 J3 J3 J8 J8 J9 J9 J10 J10 J5 J5 J6 J6 J7 J7 J11 J11 J12 J12 J13 J13 J14 J14 Lay shields of cables under this clamp then tig...

Page 58: ...pass the drain wire into the shrink tube local sup ply then fasten crimp on lugs at the end of drain wires to screws shown above Example of wiring inside the processor unit J12 main control unit For J13 and J14 sub control units see the figure at step 2 on the previous page Fixing metal Screws for drain wires of TTYCSLA cables Pass the drain wires through the shrink tubes local supply then attach ...

Page 59: ... connection or multipoint is not connected CH1 or CH2 termination resistor ON When not setting the starting ending terminal for the multipoint connection CH1 or CH2 termination resistor OFF Processor unit I O Board 24P0124 Jumper block J1 Connector J3 1 2 SHORT Termination resistor ON default setting 2 3 OPEN 1 2 OPEN Termination connector OFF 2 3 SHORT Jumper block J2 Connector J4 1 2 SHORT Termi...

Page 60: ... Isolation GND CH1 6 RD1 H In Serial CH1 input IEC61162 1 No connection TTYCS LA 4 7 RD1 C In Serial CH1 input IEC61162 1 Pin Signal In Out Description IEC61162 2 IEC61162 1 1 TD2 A Out Serial CH2 output IEC61162 1 2 TTYCS LA 4 TTYCS LA 4 2 TD2 B Out Serial CH2 output IEC61162 1 2 3 RD2 A In Serial CH2 input IEC61162 2 No connection 4 RD2 B In Serial CH2 input IEC61162 2 5 ISOGND2 Isolation GND CH...

Page 61: ...IEC61162 1 5 GND GND Pin Signal In Out Description Remarks 1 TD6 A Out Serial CH6 output IEC61162 1 Use TTYCS LA 1Q IREC61162 1 only 2 TD6 B Out Serial CH6 output IEC61162 1 3 RD6 H In Serial CH6 input IEC61162 1 4 RD6 C In Serial CH6 input IEC61162 1 5 GND GND Pin Signal In Out Description Remarks 1 TD7 A Out Serial CH7 output IEC61162 1 Use TTYCS LA 1Q IREC61162 1 only 2 TD7 B Out Serial CH7 out...

Page 62: ...A 10 2 SYS_FAIL B Out System fail output 3 PWR_FAIL A Out Power fail output 4 PWR_FAIL B Out Power fail output 5 NC1 A Out Alarm output NC1 6 NC1 B Out Alarm output NC1 7 NC2 A Out Alarm output NC2 8 NC2 B Out Alarm output NC2 9 NO1 A Out Alarm output NO1 10 NO1 B Out Alarm output NO1 11 NO2 A Out Alarm output NO2 12 NO2 B Out Alarm output NO2 13 DC12V_OUT Out ACK input 13 14 short No connection 1...

Page 63: ...ETTING menu appears only when the power is turned on for the first time after installation of the monitor unit Adjust the settings referring to the following table DVI PWR SYNC is the slide switch at the bottom rear of the monitor unit Confirm that this switch is set to ON default setting See Slide switch below for details Slide switch Set the slide switch to ON default setting This setting automa...

Page 64: ...o maintain performance This fabrication requires the optional crimping tool type CRIMPFOX 10S For the relations between the connectors and rod terminals see page AP 2 Also the stickers attached on the reverse side of the covers show the de tailed connections Attache the cables to the applicable pins Use the ferrule type terminals supplied to connect the cables to the terminals in the sensor adapte...

Page 65: ... 95 J9 1 to 4 100 5 to 8 90 J9 1 to 4 100 5 to 8 90 J9 1 to 4 100 5 to 8 90 30 30 30 80 or more 80 or more 80 or more Shield fold back Shield fold back Shield fold back Vinyl tape width 10 Vinyl tape width 10 Vinyl tape width 10 TTYCSLA 1Q cable Core 6 Core 6 Core 6 J8 1 to 4 110 5 to 8 95 J8 1 to 4 110 5 to 8 95 J8 1 to 4 110 5 to 8 95 J9 1 to 4 100 5 to 8 90 J9 1 to 4 100 5 to 8 90 J9 1 to 4 100...

Page 66: ...e width 10 Vinyl tape width 10 Vinyl tape width 10 80 or more 80 or more 80 or more TTYCS 1 cable Core 6 Core 6 Core 6 100 100 100 30 30 30 80 80 80 Shield fold back Shield fold back Shield fold back Vinyl tape width 10 Vinyl tape width 10 Vinyl tape width 10 TTYCSLA 1 cable Core 6 Core 6 Core 6 100 100 100 Vinyl tape width 10 Vinyl tape width 10 Vinyl tape width 10 80 80 80 60 60 60 Pass drain wi...

Page 67: ...tor J2 Pin Signal name In Out Remarks NO NC 1 24V_IN 24 VDC DPYC 1 5 2 24V_GND GND 24 VDC 3 PWR_FAIL_A Out Power fail output TTYCS LA 1 No connection 4 PWR_FAIL_COM Out Power fail output TTYCS LA 1 5 PWR_FAIL_B Out Power fail output No connection J1 J1 J2 J2 J4 J5 J5 J7 J7 J6 J8 J8 J9 J9 For TTYCSLA cables pass the drain wire into the shrinking tube local supply then use these crimp on lugs and sc...

Page 68: ...IEC61162 2 modbus No connection No connection 4 RD1 B In Serial CH1 out put IEC61162 2 modbus 5 ISOGND1 Isolation GND CH1 6 RD1 H In Serial CH1 out put IEC61162 1 No connection TTYCS LA 4 7 RD1 C In Serial CH1 out put IEC61162 1 Pin Signal name In Out Remarks IEC61162 2 IEC61162 1 Modbus 1 TD2 A Out Serial CH2 out put IEC61162 1 2 modbus TTYCS LA 4 TTYCS LA 4 TTYCS LA 4 2 TD2 B Out Serial CH2 out ...

Page 69: ...5 ISOGND4 Isolation GND CH4 6 RD4 H In Serial CH4 output IEC61162 1 No connection TTYCS LA 4 7 RD4 C In Serial CH4 output IEC61162 1 Pin Signal name In Out Description Used cable 1 TD5 A Out Serial CH5 output IEC61162 1 TTYCS 1Q or TTYCSLA 1Q 2 TD5 B Out Serial CH5 output IEC61162 1 3 RD5 H In Serial CH5 input IEC61162 1 4 RD5 C In Serial CH5 input IEC61162 1 5 TD6 A Out Serial CH6 output IEC61162...

Page 70: ... to remove the cover from the adapter 2 Peel the paper from the case packing then attach the case packing to the reverse side of the cover and the body unit as shown below 3 Attach the cover to the MC 3000S body unit Name Type Code No Qty Remarks Case packing serial 21 014 2051 100 367 880 10 2 For MC 3000S Binding screw Cover Case packing Case packing Case packing Case packing Cover reverse side ...

Page 71: ...ttached in unit Pass drain wire into vinyl sheath local supply then attach crimp on lug pre attached in unit Core 6 Core 6 Core 6 MPYC 12 cable MC 3030D MC1 5 W L600 1000 2000 3000 cable Output Vinyl tape width 10 Vinyl tape width 10 Vinyl tape width 10 Shield fold back Shield fold back Shield fold back Core 6 Core 6 Core 6 30 30 30 100 100 100 80 or more 80 or more 80 or more Not used Cut with 50...

Page 72: ...e 2 When changing the input method turn off the MC 3010A and on again to put change in effect J1 J1 J2 J2 J4 J4 J5 J5 J3 J3 For TTYCSLA cables pass the drain wire through the shrink tube then attach these crimp on lugs and screws to connect drain wires to here MC1 5 W L cable MC1 5 W L cable TTYCS 1 TTYCSLA 1 TTYCS 1 TTYCSLA 1 IV 1 25sq Local supply IV 1 25sq Local supply J1 J1 J2 J2 J4 J4 J5 J5 J...

Page 73: ... 1 Pin 3 4 open Pin 3 4 short 4 CURR1_JP2 Analog 2 input power current voltage setting jumper 1 Pin Signal name In Out Description Power voltage Power current 1 AN2_IN In Analog 2 input TTYCS LA 1 2 AN2_GND Analog 2 GND 3 CURR2_JP1 Analog 2 input power current voltage setting jumper 1 Pin 3 4 open Pin 3 4 short 4 CURR2_JP2 Analog 2 input power current voltage setting jumper 1 AN IN AN GND CURR JP1...

Page 74: ...Analog 3 input TTYCS LA 1 2 AN3_GND Analog 3 GND 3 CURR3_JP1 Analog 3 input power current voltage setting jumper 1 Pin 3 4 open Pin 3 4 short 4 CURR3_JP2 Analog 3 input power current voltage setting jumper 1 Pin Signal name In Out Remarks ACK1 contact ACK voltage ACK2 contact ACK2 voltage 1 DC12V_OUT Out ACK1 In Pin 1 2 short No connec tion Depending on ACK1 input 2 DIGI_IN1 In MPYC 12 3 DIGI_RTN1...

Page 75: ...GND DC12V In No connection 5 DC12V_OUT Out ACK4 In Pin 1 2 short No con nection 6 DIGI_IN4 In MPYC 12 7 DIGI_RTN4 Out MPYC 12 8 GND DC12V In No con nection Pin Signal name In Out Remarks ACK1 contact ACK voltage ACK2 contact ACK2 voltage 1 DC12V_OUT Out ACK5 In Pin 1 2 short No connec tion 2 DIGI_IN5 In MPYC 12 3 DIGI_RTN5 Out MPYC 12 4 GND DC12V In No connec tion 5 DC12V_OUT Out ACK6 In Pin 1 2 s...

Page 76: ...connec tion 5 DC12V_OUT Out ACK2 In Pin 1 2 short No con nection 6 DIGI_IN2 In MPYC 12 7 DIGI_RTN2 Out MPYC 12 8 GND DC12V In NO con nection Pin Signal name In Out Remarks Alarm1 NO Out Alarm1 NC Out Alarm2 NO Out Alarm2 NC Out 1 A1 Out Alarm1 Out MPYC 12 No connection 2 COM1 MPYC 12 3 B1 No connection 4 A2 Alarm2 Out MPYC 12 No connection 5 COM2 MPYC 12 6 B2 No connection Pin Signal name In Out R...

Page 77: ... No connection 2 COM5 MPYC 12 3 B5 No connection 4 A6 Alarm5 Out MPYC 12 No connection 5 COM6 MPYC 12 6 B6 No connection Pin Signal name In Out Remarks Alarm7 NO Out Alarm7 NC Out Alarm8 NO Out Alarm8 NC Out 1 A7 Out Alarm7 Out MPYC 12 No connection 2 COM7 MPYC 12 3 B7 No connection 4 A8 Alarm8 Out MPYC 12 No connection 5 COM8 MPYC 12 6 B8 No connection ...

Page 78: ... remove the cover from the adapter 2 Peel the paper from the case packing then attach the case packing to the reverse side of the cover and the body unit as shown below 3 Attach the cover to the MC 3010A 3020D 3030D chassis Name Type Code No Qty Remarks Case packing analog 21 014 2052 2 100 367 961 10 2 MC 3010A 3020D 3030D Binding screw Cover Case packing Case packing Case packing Case packing Co...

Page 79: ... 0 Jumper block Use the jumper block J19 to set the termination resistor on off for the MODBUS com munication on the connector J1 For the first and last sensor adapter in a series their termination resistors should be set to ON Use the MC CS Board with the default set ting because it becomes the first adapter in a series Set the jumper blocks J14 through J17 to turn the termination resistors on co...

Page 80: ...setting 2 3 OPEN 1 2 OPEN Termination resistor OFF 2 3 SHORT Jumper block J15 Connector J5 CH2 1 2 SHORT Termination resistor ON default setting 2 3 OPEN 1 2 OPEN Termination resistor OFF 2 3 SHORT Jumper block J16 Connector J6 CH3 1 2 SHORT Termination resistor ON default setting 2 3 OPEN 1 2 OPEN Termination resistor OFF 2 3 SHORT Jumper block J17 Connector J7 CH4 1 2 SHORT Termination resistor ...

Page 81: ...s allowed to use the same number between the MC 3000S and a sensor adapter Jumper block Use the jumper block J25 to set the termination resistor on off for the MODBUS com munication on the connector J1 For the first and last sensor adapter in a series their termination resistors should be set to ON If not communication between sensor adapters is not possible Jumper block J25 Connector J1 1 2 OPEN ...

Page 82: ... change to the operational ampli fier Power current Pass the power current to the shunt resistor 1k parallel combined resistance 500 to input the amount of voltage change at the both ends of the re sistor to the operational amplifier Jumper block J3 to J5 Input method 3 4 OPEN Power voltage default setting SHORT Power current AN IN AN GND CURR JP1 AN 15V AN GND AN 15V Opeamp Vin InGnd VS1 VS1 VS2 ...

Page 83: ...e clamp using the cable ties supplied No use Power port Power Fail LAN port Ground wire IV 1 25sq supplied DPYC 1 5 cable DPYC 1 5 cable to gateway network ECDIS radar etc Attach the LAN cap supplied to the unused connector holes to provide waterproofing standard IPX2 LAN cable Cable clamp ...

Page 84: ...control unit board when removing the cover 2 Unfasten two pan head screws M3x12 to remove the clamp and cable clamp from the control unit then disconnect the control unit cable from the J1 connector 3 Pull out the control unit cable from the cover 4 Pass the optional cable assy 6TPSH XH12X2 LxxSP1 through the cable hole on the control unit 5 Fasten the shield part of the cable assy with the cable ...

Page 85: ...screws M3x8 from the bottom of the control unit and a pan head screw M3x8 and flat washer from the back of the control unit to remove the cover Note Be careful not to add stress to the cables connected to the control unit board when removing the cover Loosen these three bolts to remove the upper plate Loosen this bolt to use the lower clamp holes Loosen this bolt to use the lower clamp holes Clamp...

Page 86: ... the cover 5 Fasten the shield part of the cable assy with the cable clamp removed at step 2 then connect the connector at the end of the cable assy to the J1 on the control unit board Note When clamping the shield part of the cable must not touch the circuit board Binding screw M3x8 Control unit cable Control unit cover Pan head screw and flat washer Cable clamp Disconnect this connector J1 conne...

Page 87: ...xxSP2 10 Set the shields of cables under the cable clamp then tighten the cable clamp 11 Remount the processor unit cover Cable assy Shield part Cable clamp Board Loosen these three bolts to remove the upper plate Loosen this bolt to use the lower clamp holes Loosen this bolt to use the lower clamp holes Clamp holes upper Clamp holes lower J4 J4 J3 J3 J8 J8 J9 J9 J10 J10 J5 J5 J6 J6 J7 J7 J11 J11 ...

Page 88: ...2 WIRING 2 54 This page is intentionally left blank ...

Page 89: ...lay because of the difficulty in achieving accurate initial positioning of the antenna unit The follow ing adjustment will compensate for this error 1 Select a stationary target echo at a range between 0 125 and 0 25 NM preferably near the heading line 2 Operate the EBL control to bisect the target echo TUNE button TUNE MAN Manual tuning TUNE AUTO Auto tuning TUNE button TUNE MAN Manual tuning TUN...

Page 90: ...ow The range of target echoes is also be incorrectly shown 1 Transmit on the 0 25 NM range 2 Adjust the radar picture controls to display the picture properly 3 Select a target echo which should be displayed straightly 4 Show the RADAR INSTALLATION menu then select 1 ECHO ADJ followed by 3 TIMING ADJ 5 Set a value which displays the target straightly The setting range is 0 to 4095 3 4 How to Suppr...

Page 91: ...ow to set the width and length for the picture from the exter nal radar If two FCR 2xx9 series radars are to be used for the dual radar display set the same display area on each radar to ensure proper performance 1 Open the RADAR INSTALLATION menu then select 2 SCANNER 6 DUAL RADAR SETTING to show the DUAL RADAR SET TING menu 2 Select 1 COMBINE MODE to select which ra dar to set as reference point...

Page 92: ... the dual radar display area START Start point of the sector in degrees 000 359 ANGLE Horizontal width of the sector in degrees 000 359 6 Select 3 COMBINE RANGE to set the vertical width of the sector Picture from external radar Position of external radar antenna Picture from own radar Radar selected for COMBINE MODE Own START 45 ANGLE 270 START 00 00 nm LENGTH 99 99 nm Radar selected for COMBINE ...

Page 93: ...NSTALLATION menu select 2 SCANNER 6 DUAL RA DAR SETTING 2 Select 4 EXT RADAR 3 Select required radar no Only the numbers of radar set on the RADAR INSTAL LATION menu are vaiid Note 1 The dual radar will not function if a radar incompatible to the dual radar function is selected Note 2 The dual radar display is designed to be used with two FCR 2xx9 series radars Other makes or models can be used ho...

Page 94: ...een The setting range is 0 to 32 After compleiton of the adjustment the radar goes into standby If the noise does not disappear switch to and try again 5 NEAR STC CURVE 6 MID STC CURVE 7 FAR STC CURVE Use the default setting Change the setting according to sea condition 8 RING SUPPRESSION Use the default setting Change the setting according to sea condition The larger the number the greater the ST...

Page 95: ...tor angle To erase the area enter 0 for both the START and ANGLE sections The set ting range of START is 0 to 359 and ANGLE is 0 to 180 Note Turn off a stern blind sector when adjusting the PM gain to display the echo from the perfor mance monitor properly 3 ANT REVOLUTION For HSC only Select LO for 36 rpm HI for 42 rpm AUTO sets the normal rotation speed to 36 rpm and switches the rotation speed ...

Page 96: ...cing the magnetron TX TIME can be reset to 0 6 PM GAIN ADJ Adjust the performance moni tor automatically or manually whenever the magnetron is re placed For automatic adjust ment no further operation is required close the menu at the completion of the adjustment For manual do as follows to ad just the performance monitor gain 1 Adjust the GAIN control so that a slight amount of white noise appears...

Page 97: ...connected equipment which can receive both TTM and TTD sentences Note This setting is valid for LAN connection only For serial connection the output sentence is determined on the Common Installation Set ting menu this setting is invalid See WEB SETTING MANUAL E42 01204 for details For both LAN and serial connections set the baudrate to 38 400 bps TTM TTD REFERENCE Set the output format for tracked...

Page 98: ... The setting range is 1 to 31 6 ACQ PRESET Show the ACQ PRESET menu LAND SIZE Set the land size in units of 100 m The setting range is 100 to 3000 m A target whose length is equal to or greater than the length set here is judged as a land target ANT SELECT Set the antenna radiator type of your radar The size of the echo changes with ra diator size Select the correct radiator type to en sure proper...

Page 99: ...rget Select TIME or SCAN then enter value 8 DEFAULT Restore the default settings for the RADAR INSTALLATION menu settings 1 TT W O GYRO page 2 TT can be used without a gyro Select ON to use TT without a gyro 2 TT SENSOR DATA page 2 Show debug use TT sensor data 1 TT DETAIL DATA page 2 Display TT detailed data 3 6 5 OTHERS menu Open the main menu then select 9 RADAR IN STALLATION 5 OTHERS to open t...

Page 100: ...oute source other than FMD 3200 3300 7 WIND REF TEXT Select the format of the wind information on the NAV data box For the wind refer ence set on the WIND STB Main menu 4 INFORMATION BOX 2 SET NAV DATA 6 WIND STB menu 3 7 Web Setting Menu Set up the radar from the Common Installation Setting menu on the web browser For details on the Common Installation Setting menu see the Instruction Manual E42 ...

Page 101: ...l coded bearing data for display on the radar screen This section explains how to install the GC 10 mainly consisting of the GYRO CON VERTER board and set it up according to gyrocompass connected 4 1 1 Installing the GYRO CONVERTER board Necessary parts GC 10 2 Code number 000 080 440 1 Open the processor unit Radar processor unit opened 1 1 4 1 1 2 1 3 1 2 1 3 1 1 2 1 5 1 7 1 3 ...

Page 102: ...231 607 019 FUR called J602 with two screws Attaching the GYRO CONVERTER board in the radar processor unit 3 Connect the GYRO CONVERTER board and the 03P9342 board with connector assemblies 03 2088 and 03 2091 Connector 231 231 607 019 FUR 1 7 Connector 231 231 107 026 FUR 1 1 7 7 GYRO CONVERTER board 64P1106A Screw M3X8 5 pcs Screw M2 6X10 2 pcs ...

Page 103: ...e through the cable clamp and connect it to connector J602 as shown in the figure on page 4 3 1 1 4 1 1 2 1 3 1 2 1 3 1 1 2 1 5 1 7 XH PH connector assy 03 2088 6 14P NH connector assy 03 2091 5P VH connector assy 03 2089 5P VH connector assy 03 2090 3P J1 P1 J603 P603 GYRO CONVERTER 64P1106A TB 03P9342 P608 J7 J4 J5 P5 P4 P7 J602 To P608 To J602 1 2 2 P608 1 2 3 4 BRN RED ORG YEL 1 Connection for...

Page 104: ... Close the radar processor unit 4 1 2 Connection of external power supply An external power supply is necessary when the repeater signal is step by step type and the step voltage is below 20V or output voltage is less than 5W 1 Cut jumper wire JP1 on the GYRO CONVERTER board when an external power supply is used 1 1 4 1 1 2 1 3 1 2 1 3 1 1 2 1 5 1 7 1 3 Screw M4X8 3 pcs Plastic cover Insert cables...

Page 105: ...135VAC Gear ratio 360x Supply voltage 30V to 135VAC If the specifications of the gyrocompass differ from those mentioned above change jumper wire and DIP switch settings on the GYRO CONVERTER board Settings may be changed according to gyrocompass specifications or make and model of gyrocom pass Note If you change the setting with power supplied set 8 of SW2 from OFF to ON then OFF again GYRO CONVE...

Page 106: ...pulsating current 500 Hz OFF ON AC synchronous pulsating current DC ON ON DC synchronous DC step Rotor Voltage SW2 1 JP3 20 to 45 VAC ON 2 30 to 70 VAC OFF 2 40 to 90 VAC ON 1 60 to 135 VAC OFF 1 Stator Voltage SW2 2 SW2 3 JP2 20 to 45 VAC or 20 to 60 VDC ON OFF 2 30 to 70 VAC or 40 to 100 VDC OFF OFF 2 40 to 90 VAC ON OFF 1 60 to 135 VAC OFF OFF 1 Ratio SW1 1 SW1 2 SW1 3 360X OFF OFF OFF 180X ON ...

Page 107: ... O o m e R e v 2 h t a l P I I I I I T A G V A N us o n o r h c n y s C A z H 0 6 0 5 V 0 6 0 5 e g a t l o v r o t o R V 8 6 e g a t l o v r o t a t S x 0 6 3 F F O F F O F F O F F O F F O F F O F F O F F O F F O F F O F F O 1 3 2 2 2 1 1 c e m i k o T y r r e p S e p y t 1 1 2 1 S E 2 0 1 1 0 1 T L G 7 0 1 K 6 0 1 3 0 1 s u o n o r h c n y s C A z H 0 6 0 5 V 0 1 1 0 0 1 e g a t l o v r o t o R ...

Page 108: ...tator voltage JP3 Rotor voltage JP1 Gyro type Fuse 2A J5 Rotor signal input external power input J4 Stator signal input SW1 DIP switch J6 IEC 61162 1 output port J7 Data output port 1 J8 Data output port 2 J9 Data output port 3 JP6 JP7 AD format data Tx interval SW2 DIP switch J10 Data output port 4 J11 Data output port 5 J12 Data output port 6 SW3 DIP switch ...

Page 109: ...t the LOCAL SENSOR SETTING 4 Check Analog Gyro 5 Roll the wheel to set gyrocompass reading 6 Click the OK button on the display to close the menu 4 2 Junction Box If the length of the antenna cable is more than 100 m the optional junction boxes are required These boxes should be mounted at the location protected because its wa terproofing is IPX3 RW 9600 Max 15 m Junction box RJB 001 RW 9600 Max 1...

Page 110: ...unting location with four sets of M8 bolt and nut 4 2 2 Cable fabrication RW 9600 514 474 320 280 139 360 430 270 60 NAMEPLATE 4 ø10 FIXING HOLES Mass 12kg 6 14 5 9 approx 450 5 20 Armor Units mm Shield Vinyl sheath Pull out inner cables from here Shield Coaxial cable Crimp on lug for M8 ...

Page 111: ...erminal board referring to the interconnection dia gram on next page Flat washer Cable gland Vinyl sheath Clamping gland Gasket Cut and trim armor 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 RG12 UY RG 12 UY TTYCY 4 DPYCY 6 RW 9600 Connect inner conductors M8 screw for grounding Clamp outer conductor of coaxial cables Fix wires with cable tie ...

Page 112: ...1 12 13 14 15 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 N C DPYCY 6 DPYCY 6 1 2 1 2 RED B GRN B WHT BLK GRN RED WHT B PPL B COAX GLY B BLU B YEL B ORG B BRN RG 12 UY TTYCY 4 N C N C N C 03P9349 TB802 12 2 13 14 3 4 5 6 7 8 9 10 11 1 TB801 GND SIG GND 1 2 Box Junction Transceiver unit GND IF_VIDEO_IN RF_SPU_D_B RF_SPU_D_A SPU_RF_D_B SPU_RF_D_A MOTOR MOTOR MOTOR MOTOR 24V_MINUS 24V_PLUS N C TX HV RED B GR...

Page 113: ... Specification Contents Remarks Remote display signal HD BP Trigger Video 2 ports Data Specification Contents Remarks Heading signal IEC61162 2 Speed signal IEC 61162 1 Ed 4 Navaid data IEC 61162 1 Ed 4 Position time and date datum course speed wind current depth temperature NAVTEX etc AIS signal IEC 61162 2 Alarm handling signal Contact closure Input from alarm system IEC 61162 1 Ed 4 Input from ...

Page 114: ...rue THS HDT NAVTEX received message NRX Time and Date ZDA Datum DTM Acknowledge alarm ACK UAIS VHF Data link Message VDM UAIS VHF data link Own vessel report VDO AIS addressed and binary broadcast acknowledgement ABK AIS voyage static data VSD Wind Speed and Angle True MWV T Wind Speed and Angle Relative MWV R Depth DPT DBT Water Temperature MTW Route Transfer Report RRT Set and Drift CUR VDR Set ...

Page 115: ...1 11mm 12 6mm TTYCY 4 0 75mm2 1 11mm 17 7mm TTYCY 4S 0 75mm2 1 11mm 21 1mm TTYCY 4SLA 0 75mm2 1 11mm 19 5mm TTYCYS 1 0 75mm2 1 11mm 12 1mm TTYCYS 4 0 75mm2 1 11mm 18 5mm TTYCYSLA 1 0 75mm2 1 11mm 11 2mm TTYCYSLA 4 0 75mm2 1 11mm 17 9mm EX TTYCYSLA 4 MPYC 4 Designation type of twisted pairs Designation type of cores 1 2 3 4 5 6 1 2 3 4 Cables listed in the manual are usually shown as Japanese Indus...

Page 116: ... AI 0 75 6 GY Gray TTYCS 4 TTYCSLA 4 4 PWR_FAIL COM 5 PWR_FAIL B 6 NC Connector Pin Signal name Rod terminal to use Connected cable J4 1 TD1 A AI 0 75 6 GY Gray TTYCS 4 TTYCSLA 4 2 TD1 B 3 RD1 A 4 RD1 B 5 ISOGND1 6 RD1 H 7 RD1 C Connector Pin Signal name Rod terminal to use Connected cable J5 1 TD2 A AI 0 75 6 GY gray TTYCS 4 TTYCSLA 4 2 TD2 B 3 RD2 A 4 RD2 B 5 ISOGND2 6 RD2 H 7 RD2 C Connector Pi...

Page 117: ... 7 RD4 C Connector Pin Signal name Rod terminal to use Connected cable J8 1 TD5 A AI 0 75 6 GY gray TTYCS 1Q TTYCSLA 1Q 2 TD5 B 3 RD5 H 4 RD5 C 5 TD6 A TTYCS 1Q TTYCSLA 1Q 6 TD6 B 7 RD6 H 8 RD6 C Connector Pin Signal name Rod terminal to use Connected cable J9 1 TD7 A AI 0 75 6 GY gray TTYCS 1Q TTYCSLA 1Q 2 TD7 B 3 RD7 H 4 RD7 C 5 TD8 A TTYCS 1Q TTYCSLA 1Q 6 TD8 B 7 RD8 H 8 RD8 C ...

Page 118: ... Rod terminal to use Connected cable J2 1 24V_OUT AI 0 34 6 TQ blue MC1 5 W Lxxx 2 24V_GND 3 MODBUS A AI 0 14 8 GY gray 4 MODBUS B 5 GND Connector Pin Signal name Rod terminal to use Connected cable J3 1 AN1_IN AI 0 75 6 GY gray TTYCS 1 TTYCSLA 1 2 AN1_GND 3 CURR1_JP1 4 CURR1_JP2 Connector Pin Signal name Rod terminal to use Connected cable J4 1 AN2_IN AI 0 75 6 GY gray TTYCS 1 TTYCSLA 1 2 AN2_GND...

Page 119: ...cable J2 1 24V_OUT AI 0 34 6 TQ blue MC1 5 W Lxxx 2 24V_GND 3 MODBUS A AI 0 14 8 GY gray 4 MODBUS B 5 GND Connector Pin Signal name Rod terminal to use Connected cable J3 1 DV12V_OUT1 AI 1 6 RD red MPYC 12 2 DIGI_IN1 3 DIGI_RTN1 4 GND 5 DC12V_OUT2 6 DIGI_IN2 7 DIGI_RTN2 8 GND Connector Pin Signal name Rod terminal to use Connected cable J4 1 DV12V_OUT3 AI 1 6 RD red MPYC 12 2 DIGI_IN3 3 DIGI_RTN3 ...

Page 120: ... the jumper connection is necessary between 1 and 2 and 5 and 6 depending on the input specification Connector Pin Signal name Rod terminal to use Connected cable J6 1 DV12V_OUT7 AI 1 6 RD red MPYC 12 2 DIGI_IN7 3 DIGI_RTN7 4 GND 5 DC12V_OUT8 6 DIGI_IN8 7 DIGI_RTN8 8 GND ...

Page 121: ..._GND 3 MODBUS A AI 0 14 8 GY gray 4 MODBUS B 5 GND Connector Pin Signal name Rod terminal to use Connected cable J3 1 A1 AI 1 6 RD red MPYC 12 2 COM1 3 B1 4 A2 5 COM2 6 B2 Connector Pin Signal name Rod terminal to use Connected cable J4 1 A3 AI 1 6 RD red MPYC 12 2 COM3 3 B3 4 A4 5 COM4 6 B4 Connector Pin Signal name Rod terminal to use Connected cable J5 1 A5 AI 1 6 RD red MPYC 12 2 COM5 3 B5 4 A...

Page 122: ...IS Addressed and binary broadcast acknowledgement ACK Acknowledge alarm D0 D1 D2 D3 D4 D5 D6 D7 Start bit Stop bit Data bits ABK xxxxxxxxx x x x x x hh CR LF 1 2 3 4 5 1 MMSI of the addressed AIS unit 9 digits 2 AIS channel of reception No use 3 Message ID 6 8 12 14 4 Message sequence number 0 9 5 Type of acknowledgement See below 1 message was broadcast 6 or 12 but not ACK by addressed AIS unit 2...

Page 123: ...th ACN and ACM ALR Hhmmss ss xxx A A c c hh CR LF 1 2 3 4 5 1 Time of alarm condition change UTC 000000 00 235960 99 2 Unique alarm number identifier at alarm source 000 999 3 Alarm condition A threshold exceeded V not exceeded 4 Alarm acknowledge state A acknowledged V not acknowledged 5 Alarm description text alphanumeric characters max 32 CUR A x x x x x x x a x x x x x x a a hh CR LF 1 2 3 4 5...

Page 124: ...oidal separation No use 12 Unit m No use 13 Age of differential GPS data 0 999 14 Differential reference station ID No use GLL llll lll a yyyyy yyy a hhmmss ss a x hh CR LF 1 2 3 4 5 6 7 1 Latitude 0000 00000 9000 00000 2 N S 3 Longitude 0000 00000 18000 00000 4 E W 5 UTC of position No use 6 Status A data valid V data invalid 7 Mode indicator A Autonomous D Differential E Estimated M Manual input...

Page 125: ...0 00 360 00 2 Reference R T R Relative T Theoretical 3 Wind speed 0 00 9999 99 4 Wind speed units K km h M m s N nm 5 Status A NRX xxx xxx xx aaxx x hhmmss ss xx xx xxxx x x x x A c c hh CR LF 1 2 3 4 5 6 7 8 9 10 11 12 13 1 Number of sentences 001 to 999 2 Sentence number 001 999 3 Sequential message ID 00 to 99 4 Navtex message code aaxx aa AA to ZZ xx 00 to 99 5 Frequency table index 0 to 3 nul...

Page 126: ...te Max 30 characters 3 Version of transferred route Max 20 characters 4 ID of current waypoint for monitored route Max 10 characters 5 File transfer statues of transferred route A Successful reception of the route file transfer E Error in reception of the route file transfer 6 Status of the intended application of the transferred route A Content of the received route accepted and valid V Content o...

Page 127: ... 63 bytes 6 Number of fill bits 0 to 5 VDR x x T x x M x x N hh CR LF 1 2 3 4 5 6 1 Direction degrees 0 00 360 00 null 2 T True fixed 3 Direction degrees 0 00 360 00 null 4 M Magnetic fixed 5 Current speed 0 99 99 6 N Knots fixed VHW x x T x x M x x N x x K hh CR LF 1 2 3 4 5 6 7 8 1 Heading degrees No use 2 T True fixed No use 3 Heading degrees No use 4 M Magnetic fixed No use 5 Speed knots 0 00 ...

Page 128: ...dicator A Autonomous D Differential E Estimated dead reckoning M Manual input S Simulator P Precision ZDA hhmmss ss xx xx xxxx xx xx CR LF 1 2 3 4 5 6 1 UTC 000000 00 235960 99 2 Day 01 31 3 Month 01 12 4 Year UTC 1970 2037 5 Local zone hours No use 6 Loca zone minutes No use ABM x x x xxxxxxxxx x x x s s x hh CR LF 1 2 3 4 5 6 7 8 1 Total number of sentences needed to transfer the message 1 9 2 M...

Page 129: ... aaa x x x x x x x c c hh CR LF 1 2 3 4 5 6 7 8 9 10 11 12 13 1 Total number of ALF sentences this message 1 2 2 Sentence number 1 2 3 Sequential message identifier 0 to 9 4 Time of last change hh 00 to 23 mm 00 to 59 ss ss 00 00 to 60 99 null 5 Alert category A Alert category A B Alert category B C Alert category C null 6 Alert priority A Alarm W Warning C Caution null when 2 is 2 7 Alert state V...

Page 130: ... 99 2 Tag code used for identification of source of event RA0001 RA0010 EI0001 EI0016 IN0001 IN0016 II0001 II0016 3 Event description OPERATION OSD x x A x x R x x x x x x x x N hh CR LF 1 2 3 4 5 6 7 8 9 1 Heading degrees true 0 00 359 99 null 2 Heading status A data valid V data invalid 3 Vessel course degrees true 0 00 359 99 null 4 Course reference B M W R P null B Bottom tracking log M Manual...

Page 131: ...Range units K N S 13 Display rotation see note 1 NOTES 1 Display rotation C Course up course over ground up degrees true H Head up ship s heading center line 0 up N North up true north is 0 up 2 Origin 1 and origin 2 are located at the stated range and bearingfrom own ship and provide for two independent sets of variable range markers VRM and electronic bearing lines EBL originating away from own ...

Page 132: ...n increasing 99 99 99 99 null 10 Speed distance units N nm 11 Target name null 12 Target status L Lost Q Acquiring T Tracking 13 Reference target R NULL otherwise 14 UTC of data null 15 Type of acquisition A Automatic M Manual VSD x x x x x x c c hhmmss ss xx xx x x x x hh CR LF 1 2 3 4 5 6 7 8 9 1 Type of ship and cargo category 0 255 2 Maximum present static draught 0 to 25 5 meters null 3 Perso...

Page 133: ...162 2 1 input output TD A SN65LBC172 TD B 10 ohm 10 ohm 10 ohm Processor Unit Sensor Adapter IEC 61162 1 output Processor Unit Sensor Adapter IEC 61162 1 input PC 400 RD H RD C 470 ohm LTC1535 TD A TD B ISOGND RD A RD B PC 400 RD H RD C 110 ohm 470 ohm Set with jumper Switchable open close ...

Page 134: ...CE ONLY 型式 コード番号が2段の場合 下段より上段に代わる過渡期品であり どちらかが入っています なお 品質は変わりません TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT QUALITY IS THE SAME C3527 Z04 A A 1 P P ACKING LIST 03GP X 9851 0 RSB 104 RSB 105 N A M E O U T L I N E DESCRIPTION CODE Q TY 1 1 ユニット UNIT 空中線本体部 ANTENNA UNIT RSB 104 N S 000 081 712 1 付属品 ACCESSORIES 付属品 ACCESSORIES FP03 1...

Page 135: ...䈲ᄌ䉒䉍䉁䈞䉖䇯 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 C3527 Z07 A A 3 P P ACKING LIST 03GP X 9852 0 RTR 082 N A M E O U T L I N E DESCRIPTION CODE Q TY 1 1 ユニット UNIT 送受信部 TRANSCEIVER UNIT RTR 082 104S 000 081 741 1 工事材料 INSTALLATION MATERIALS 工事材料 INSTALLATION MATERIALS CP03 27601 008 540 570 1 1 コ ド番号末尾の は 選...

Page 136: ...00 176 720 1 1 3 取扱説明CD OPERATOR S MANUAL CD FMD3X00 O M CDROM E 000 176 721 1 1 3 取扱説明CD OPERATOR S MANUAL CD FCR2XX9 O M CDROM E 000 176 722 1 1 3 操作要領書 OPERATOR S GUIDE OS 44730 000 176 127 1 1 4 操作要領書 OPERATOR S GUIDE OSE 36040 000 176 133 1 1 4 装備要領書 INSTALLAION MANUAL IM 44730 000 176 129 1 1 5 装備要領書 INSTALLAION MANUAL IME 36040 000 176 135 1 1 5 装備要領書 INSTALLAION MANUAL IME 36060 000 176 13...

Page 137: ...STALLATION MANUAL IM 35190 000 175 544 1 1 3 装備要領書 INSTALLATION MANUAL IM 35210 000 148 687 1 1 3 装備要領書 INSTALLATION MANUAL IM 35220 000 148 691 1 1 3 装備要領書 INSTALLATION MANUAL IM 35222 000 176 947 1 1 3 装備要領書 INSTALLATION MANUAL IM 35230 000 148 690 1 1 3 装備要領書 INSTALLATION MANUAL IM 35270 000 148 693 1 1 3 操作要領書 OPERATOR S GUIDE OS 35190 000 153 046 1 1 3 操作要領書 OPERATOR S GUIDE OS 35220 000 170 ...

Page 138: ...㺩㺻 86 66 0 76 ᕤ ᮦᩱ 167 7 21 0 7 5 6 3 䠄 ᅗ䛾ᑍἲ䛿䚸ཧ 䛷䛩䚹㻌㻌㻰㻵㻹㻱㻺㻿㻵㻻㻺㻿㻌㻵㻺㻌㻰㻾㻭㼃㻵㻺㻳㻌㻲㻻㻾㻌㻾㻱㻲㻱㻾㻱㻺㻯㻱㻌㻻㻺㻸㼅㻚䠅 A 7 㹎㸿㹁㹉㹇㹌㹅ࠉ㹊㹇㹑㹒 5 8 0 1 0 2 8 7 1 6 5 37 21 2 θ 4 7 ࣘࢽࢵࢺ 81 7 㺢㺵㺍㺖㺬㺼㺎㺷 స㒊 75 21752 81 7 5 8 0 ᒓရ 6625 6 ᒓရ 6625 6 3 ᕤ ᮦᩱ 167 7 21 0 7 5 6 㺗㺎㺪㺼㺷 㺖㺮㺩㺻 86 66 0 76 ᕤ ᮦᩱ 167 7 21 0 7 5 6 3 䠄 ᅗ䛾ᑍἲ䛿䚸ཧ 䛷䛩䚹㻌㻌㻰㻵㻹㻱㻺㻿㻵㻻㻺㻿㻌㻵㻺㻌㻰㻾㻭㼃㻵㻺㻳㻌㻲㻻㻾㻌㻾㻱㻲㻱㻾㻱㻺㻯㻱㻌㻻㻺㻸㼅㻚䠅 A 8 ...

Page 139: ...㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰㩷㪙㪜㩷㪪㪟㪠㪧㪧㪜㪛㩷㪠㪥㩷㪧㪣㪘㪚㪜㩷㪦㪝㩷㪫㪟㪜㩷㪬㪧㪧㪜㪩㩷 㪧㪩㪦㪛㪬㪚㪫㪅㩷㪨㪬㪘㪣㪠㪫㪰㩷㪠㪪㩷㪫㪟㪜㩷㪪㪘㪤㪜㪅 A 9 㧼 㧼 㧭㧯㧷㧵㧺㧳 ޓ 㧸㧵㧿㨀 2 0 1 7 6 0 5 4 26 10 1 ͳ 3 6 Ꮏ ᢱ 056 6 10 6 4 5 㩃㨺㩖㩨㩣 㩂㩚㩕㩧 55 57 2 㩃㨺㩖㩨㩣 㩂㩚㩕㩧 55 2 2 㩃㨺㩖㩨㩣 ຠ 0 0 55 1 䋨 䈱ኸᴺ䈲䇮ෳ ୯䈪䈜䇯㩷㩷㪛㪠㪤㪜㪥㪪㪠㪦㪥㪪㩷㪠㪥㩷㪛㪩㪘㪮㪠㪥㪞㩷㪝㪦㪩㩷㪩㪜㪝㪜㪩㪜㪥㪚㪜㩷㪦㪥㪣㪰㪅䋩 ဳᑼ㪆䍘䍎䍢䍼 ภ䈏䋲Ბ䈱႐ว䇮ਅᲑ䉋䉍 Ბ䈮ઍ䉒䉎ㆊᷰᦼຠ䈪䈅䉍䇮䈬䈤䉌䈎䈏 䈦䈩䈇䉁䈜䇯䇭䈭䈍䇮ຠ 䈲ᄌ䉒䉍䉁䈞䉖䇯 㪫㪮㪦㩷㪫㪰㪧㪜㪪㩷㪘㪥㪛㩷㪚㪦㪛㪜㪪㩷㪤㪘㪰㩷㪙㪜㩷㪣㪠㪪㪫㪜㪛㩷㪝㪦㪩㩷㪘㪥㩷㪠㪫㪜㪤㪅㩷㩷㪫㪟㪜㩷㪣㪦㪮㪜㪩㩷㪧㪩㪦㪛㪬㪚㪫㩷㪤㪘㪰...

Page 140: ...05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 11 2 12 7 3 ࠉࠉᅗ 287 1 ྡࠉࠉ 1 0 ᩘ㔞 4 7 㸭ഛ 5 0 5 6 ྕ 12 ᆺྡ㸭つ᱁ 6 5 37 216 167 7 21 0 7 5 6 ᕤ ᮦᩱ 3 㺗㺎㺪㺼㺷 ရ 2 66 0 3 66 0 㑅ᢥࠉ72 6 7 2 12 㺗㺎㺪㺼㺷 ရ 2 66 0 3 66 0 㑅ᢥࠉ72 6 7 2 12 㺗㺎㺪㺼㺷 ရ 66 0 6 0 㑅ᢥࠉ72 6 7...

Page 141: ... 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 13 2 12 7 3 3 ࠉࠉᅗ 287 1 ྡࠉࠉ 1 0 ᩘ㔞 4 7 㸭ഛ 5 0 5 6 ྕ 12 ᆺྡ㸭つ᱁ 6 5 37 216 167 7 21 0 7 5 6 ᕤ ᮦᩱ 3 㜵Ỉ㺪㺆㺷㺯 7 57 7 0 52 6 2 12 2㺶㺻㺖㺼 6 2 5 1 6 6 2 12 㺨㺼㺦ᗙ㔠 635 1 6 5 0 686 2 12 භゅ㺣㺍㺢 㺚㺋 187 0 686 2 12 㺮㺔㺼㺕 ᖹᗙ㔠 7 6 5 0 686 2 12 භゅ㺛㺶㺺㺶 㺜㺯㺛 2 7 6 277 6 5 0 686 2 12 භゅ㺛㺶㺺㺶ࠉ㺬㺼㺷㺢 21 6 27 2 7 0 686 2 12 ᑟἼ ᢲ ᆺ 9 8 03 56 2 12 ᑟἼ ಖㆤ㺘㺼㺯 58 86 21 5...

Page 142: ...ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ 㩤㨺㩊㩨㨺㩤㩂㩎㩀㩨㨼㩎㩨 4 3 4 4 4 6 7 4 㩤㩂㩎㩀㩨㨼㩎㩨 9 8 7 4 ㆬᛯ ޓ ޓޓޓ 61 5 6 1 01 4 㩤㩂㩎㩀㩨㨼㩎㩨 9 8 7 4 ㆬᛯ ޓ ޓޓޓ 61 5 6 1 01 4 㩤㩂㩎㩀㩨㨼㩎㩨 9 8 7 4 ㆬᛯ ޓ ޓޓޓ 61 5 6 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ڏ ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 ...

Page 143: ...߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 17 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ ᠲ 㩤㩔㩨㨺 6 4 0 12 0 4 ᓮㇱ ޓޓޓޓޓޓ 14 241 5514 70 6 1 01 ᠲ 㩤㩔㩨㨺 6 4 0 12 0 4 ᓮㇱ ޓޓޓޓޓޓ 14 241 5514 70 6 1 01 ሶ 4 2 10 7 8 ᓮㇱ ޓޓޓޓޓޓ 14 241 5514 70 6 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ...

Page 144: ... 19 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ 㒐ⲁࠧࡓ 14415 10 2411 47 4 41 5 1 01 㩆㨺㩣㩦㨹㩆㨶㨺 5 9 5 4 41 5 1 01 ᠲ 㩤㩔㩨㨺 6 4 0 12 0 4 1 01 ሶ 4 2 10 7 8 1 01 㩔㩨㩒ᐳ 524 0 9 5 4 575 1 01 㩚㩀㩨㩁㩙㩣ᐔᐳ 6 9 5 4 575 1 01 ⷺ㩏㨹㩎 㩆㨷 10 076 575 1 01 ⷺ㩘㩨㩣㩎 ో㩒㩆㩨 10 5 4 9 575 1 01 㩔㩨㩒ᐳ 524 0 9 5 4 575 1 01 㩚㩀㩨㩁ᐔᐳ 6 9 5 4 575 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ...

Page 145: ...ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 21 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ 2 ࡇࡦ 㧕 2 0 1 01 41 5 ᠲ 㩤㩔㩨㨺 6 4 0 12 0 4 1 01 ሶ 4 2 10 7 8 7 1 01 ሶ 4 2 10 7 8 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖ...

Page 146: ... 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 23 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ 2 㩚㩀㩨㩁ᐔᐳ 6 9 5 4 575 1 01 ⷺ㩏㨹㩎 㩆㨷 10 076 575 1 01 ⷺ㩘㩨㩣㩎 10 1 6 575 1 01 㩃㨺㩖㩨㩣 ຠ 55 49 1 01 49 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 ...

Page 147: ...ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 25 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 056 6 10 6 4 5 Ꮏ ᢱ 㩎㩡㩇㩊㨹㩕㩩㩧㩒㩆㩨 ޓ 㩆㨷 5 6 22 0 5 4 9 575 1 01 㩄㩧㩗㩨㨹㩂㩇 108 8 0 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว...

Page 148: ...ㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 27 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 5514 5 ઃዻຠ 1 ษࠅ ߍ ౕ 6 0 674 41 5 1 01 ขઃ 㩀㩡㨺 1 4 14 6 0 674 41 5 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 69...

Page 149: ...91 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 29 1 01 6 2 2 ޓޓ 176 0 ฬ ޓޓ 0 ᢙ 3 6 ㅜ㧛 4 4 5 ภ 01 ဳฬ㧛ⷙᩰ 5 4 26 105 5514 5 ઃዻຠ ථ ขઃ 5 0 2 6 1 01 75 㩆㨺㩎 75 5 6 1 01 㩏㩗㩨㩈㩛㩇 9 5 4 5 4 9 9 0 1 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 14 4 4 0 10 㧕 㧲㨁㧾㨁㧺㧻 ޓ 㧱㧸㧱㧯㨀㧾㧵㧯 ޓ 㧯㧻 ޓ 㧚㧘㧸㨀㧰 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 2...

Page 150: ...ࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 31 1 01 6 2 52 6 01 0 1 2 46 176 0 9 01 14 2 4 5 6 2 4 8 5 52 4 914 0 37 06 6 4 4 5 1 01 1 01 2 5 2 01 52 4 2 465 56 14 7 5 5 65 2 4 8 55 6 2 01 5 㩀㨺㩘㩨㩧㩖㩨㩡㩆 5 4 10 475 4 5 0 74701 64 1 6 9 01 㧔 ߩኸᴺߪ ޔ ෳ ୯ߢߔ ޓޕ 05 105 0 4 9 0 ޓ 14 4 4 0 10 㧕 2 ဳᑼ 㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪ ᄌࠊࠅ ߖࠎ ޕ 69...

Page 151: ...6 5 A 33 C C ODE NO 008 535 920 00 TYPE SP03 14405 ITEM NO NAME OF PART OUTLINE DWG NO OR PER SET PER VES SPARE WORKING QUANTITY REMARKS CODE NO BOX NO P SHIP NO SPARE PARTS LIST FOR U S E SETS PER VESSEL 1 TYPE NO 03GL X 9306 1 1 ヒューズ FGBO 250V 5A PBF 4 AC220用 FOR PROCESSOR UNIT FUSE 000 155 840 10 1 1 1 MFR S NAME FURUNO ELECTRIC CO LTD DWG NO 略図の寸法は 参考値です DIMENSIONS IN DRAWING FOR REFERENCE ON...

Page 152: ...FURUNO ELECTRIC CO LTD DWG NO 略図の寸法は 参考値です DIMENSIONS IN DRAWING FOR REFERENCE ONLY C3519 P06 B 型式 コード番号が2段の場合 下段より上段に代わる過渡期品であり どちらかが入っています なお 品質は変 わりません TWO TYPES AND CODES MAY BE LISTED FOR AN ITEM THE LOWER PRODUCT MAY BE SHIPPED IN PLACE OF THE UPPER PRODUCT QUALITY IS THE SAME A 35 2 12 7 3 63 7 0 12 1 0 2 3 3 57 287 1 12 25 3 5 6 6 7 3 5 9 9 6 63 5 25 1 48 17 7 5 0 5 6 2 12 2 12 3 6 3 12 6...

Page 153: ...㩄㨺㩎㩨 ภ߇㧞Ბߩ႐ว ޔ ਅᲑࠃࠅ Ბߦઍࠊࠆㆊᷰᦼຠߢ ࠅ ޔ߅ߥޓޕߔ ߡߞ ߇߆ࠄߜߤޔ ຠ ߪ ᄌࠊࠅ ߖࠎ ޕ 691 6 2 5 0 1 5 56 14 0 6 6 19 4 241 7 6 5 22 0 2 1 6 722 4 241 7 6 37 6 5 6 5 A 37 2 12 7 3 3 ࠉࠉᅗ 287 1 ྡࠉࠉ 1 0 ᩘ㔞 4 7 㸭ഛ 5 0 5 6 ྕ 12 ᆺྡ㸭つ᱁ 6 5 37 216 167 7 21 0 7 5 6 ᕤ ᮦᩱ ྠ 㺗㺎㺪㺼㺷ᕤ 25 5 5ࠉ 2 167 7 21 3 0 5 1 5 5 㺏㺙㺩6㺡㺎㺪㺽 3 67 6 7 3 00 0 2 12 㺏㺙㺩1㺡㺎㺪㺽 3 67 1 7 3 00 0 2 12 㺗㺎㺪㺼㺷 㺨㺼㺻㺢㺼 1 2 12 㸦 ᅗࡢᑍἲࡣࠊཧ ࡍࠋࠉ 0 16 216 1 5 1 25 5 5 1 21 㸧 ...

Page 154: ...D 1 Y Hatai ...

Page 155: ...D 2 14 Feb 2011 Y NISHIYAMA ...

Page 156: ...D 3 16 Jun 2011 Y NISHIYAMA ...

Page 157: ...D 4 Y Hatai ...

Page 158: ...May17 07 R Esumi D 5 ...

Page 159: ...13 Feb 2014 H MAKI D 6 ...

Page 160: ...D 7 24 May 2012 Y NISHIYAMA ...

Page 161: ...D 8 24 May 2012 Y NISHIYAMA ...

Page 162: ...D 9 24 May 2012 Y NISHIYAMA ...

Page 163: ...D 10 ...

Page 164: ...D 11 ...

Page 165: ...D 12 ...

Page 166: ...D 13 12 May 2015 H MAKI ...

Page 167: ...13 Jan 2012 Y NISHIYAMA 西山義浩 電子署名者 西山 義浩 DN cn 西山義浩 o ou 情技課 email yoshihiro nishiyama furuno co jp c JP 日本 日付 2012 01 13 14 53 33 09 00 D 14 ...

Page 168: ...13 Jan 2012 Y NISHIYAMA 西山 義浩 電子署名者 西 義浩 DN cn 西山 浩 o ou 情技 email yoshih nishiyama fu o co jp c JP 日付 2012 01 14 54 40 09 0 D 15 ...

Page 169: ...13 Jan 2012 Y NISHIYAMA 西山義浩 D 16 ...

Page 170: ...13 Jan 2012 Y NISHIYAMA D 17 ...

Page 171: ...D 18 ...

Page 172: ... ᄥ ࠪࡠ ࠢࡠ 㩚㩎㩨㩢 ࠕࠞ ࠪࡠ ᄥ 㩛㩡㩅㩁 ᄥ ࡂࠗ ᄥ ࠕࠝ ᄥ ࠠ ᄥ ࠗ ᄥ ࡖ 40 14 7 4 22 9 6 4 40 4 40 9 6 2 6 2 8 Ǿ 2 8 US 2 47 64 05 14 4 ࡦࠬ 8 Ǿ 5 0514 108 46 4 49 O Ǿ 6 6 4 4 4 4 51 0 66 5 6 6 4 4 4 4 51 0 66 5 0 6 6 4 4 66 5 3 0 6 6 4 4 66 5 3 0 6 6 4 4 66 5 3 0 6 6 4 4 66 5 3 0 6 6 4 4 66 5 3 0 6 6 4 4 66 5 3 0 0 0 0 01 01 01 01 0 5 5A 5 5A 294A 294A 8A176 A 0 A460 0 8 2 2 2 2 2 2 2 014 15 014 12 0 66 5 2 2 2 2 5 41 25...

Page 173: ...5 5A 5 5A 294A 294A 8A176 A 0 A460 0 8 2 2 2 2 2 2 2 014 15 014 12 0 66 5 2 2 2 2 5 41 25 1 1 5170 4 㘑ㅦ 㘑ะ 4 0 86 4 5 56 0 1 6 4 2 2 2 2 6 1 4 0 527A4 A 527A4 A 4 A527A 4 A527A 6 A 8 0 8A2 75 8A 075 5 0 A8 1 8 US 6 2 2 2 47 8 Ǿ 8 Ǿ 8 8 0 49 6 8 US 6 6 ㅍฃାㇱ 64 05 8 4 70 6 14 4 㒐ᱛ 464 7 8 9 6 ࡖ 40 4 ࠕࠞ ࠗ 14 ࠠ 2 2 2 A A A 6 A 6 41 108 46 4 2 1 4 427 8 8 41A4 41A4 0 41A5 41A5 41A5 41A6 41 108 46 4 056...

Page 174: ...3 DC12V_OUT1 DIGI_IN1 GND GND DC12V_OUT2 DIGI_IN2 1 2 3 4 5 6 7 8 GND GND J4 DC12V_OUT3 DIGI_IN3 DC12V_OUT4 DIGI_IN4 1 2 3 4 5 6 7 8 GND GND 1 2 3 4 5 6 7 8 GND GND 1 MPYC 12 1 MPYC 12 DIGITAL IN 1 4 DIGITAL IN 5 8 1 CONTACT CLOSURE 24VDC CURRENT 2 IV 1 25sq 1 2 3 4 5 24V_IN 24V_GND MOD_BUS A MOD_BUS B GND 1 2 3 4 5 J1 J2 DIGITAL OUT 1 2 3 4 5 6 J3 A1 COM1 B1 A2 COM2 B2 1 2 3 4 5 6 1 2 3 4 5 6 1 2...

Reviews: