2. WIRING
2-13
3. Connect each wire to TB801, TB802, TB803, TB911 and TB912 referring to the
interconnection diagram.
4. Connect the grounding wire (shipyard supply) between the grounding terminal
(behind the cable clamp) and grounding point.
Connecting the coaxial cable
Connect the coaxial cable to the transceiver unit as below.
1. Loosen eight bolts (M6x20) to remove the dust cover from the output WG adapter.
2. Fasten eight bolts (removed at step 1) to attach the flange to the transceiver unit.
3. Attach the coaxial cable to the converter of the flange.
TB802
TB803
TB801
TB911
TB912
M6x20 (8 pcs.)
Circulator
Adapter
Output WG adapter
Coaxial cable
Converter
:M6x20 (8 pcs.)
Transceiver unit, internal view
Flange