APPENDIX
AP-4
Installation when retraction tank is 600 mm to 750 mm long
1. Follow the steps 1 to 5 in the previous procedure.
2. Modify the transducer travel to 450 mm by changing the upper limit switch position.
Upper limit switch.
Move the upper limit switch
to modify to 450 mm travel.
3. Assemble the hull unit completely, taking the following points into account. Refer to
chapter 1 for details of assembling and installation.
a)
The tank guide should be installed at a position 162 mm above the top of the
transducer flange.
Tank guide
162 mm
*
*Measure from the inside of the tank guide.
b)
The shaft retainer should be in contact with the waterproofing attachment.
Summary of Contents for CSH-5L
Page 1: ...PRINTED IN JAPAN COLOR SCANNING SONAR CSH 5L ...
Page 18: ...1 MOUNTING 1 10 ...
Page 19: ...1 MOUNTING 1 11 ...
Page 64: ......
Page 74: ......
Page 75: ......
Page 76: ......
Page 77: ......
Page 78: ......
Page 79: ......
Page 80: ......
Page 81: ......
Page 82: ......
Page 83: ......
Page 84: ......
Page 85: ......
Page 86: ......
Page 87: ......
Page 88: ......
Page 89: ......
Page 90: ......
Page 91: ......
Page 92: ......
Page 95: ......
Page 96: ......
Page 97: ......
Page 98: ......
Page 99: ......
Page 100: ......