3. ADJUSTMENT
3-2
To measure the peak-to-peak voltage (Vpp), expand the waveform to 5 µs/div. In the
example shown on the previous page, the amplitude is 220 Vpp.
Typical value of TX output (68 kHz)
CH Vout
+,
- CH Vout
+,
- CH Vout
+,
-
1
100 Vpp
5
240 Vpp
9
175 Vpp
2
100 Vpp
6
240 Vpp
10
175 Vpp
3
175 Vpp
7
240 Vpp
11
100 Vpp
4
175 Vpp
8
240 Vpp
12
100 Vpp
Typical value of TX output (55 kHz)
CH Vout
+,
- CH Vout
+,
- CH Vout
+,
-
1 140
Vpp 5 310
Vpp 9 240
Vpp
2 140
Vpp 6 310
Vpp 10 240
Vpp
3 240
Vpp 7 310
Vpp 11 140
Vpp
4 240
Vpp 8 310
Vpp 12 140
Vpp