12-16
MAINTENANCE AND INSPECTION OF CARRIER
★
If the monitor lamp lights
soon after the cleaned air clean-
er element has been fitted,
replace it with new element.
★
Repeated cleaning of the air
filter element is up to 5 times.
Do not try cleaning 6 times but
replace it with new element.
CAUTION
3
Wipe out inside of the body with a piece
of clean cloth.
4
Attach a new or the cleaned outside ele-
ment.
5
Fit the dust cup and clamp it.
Clamp
Dust cup
6
Check the air piping for tightness of
piping such as in hose clamps.