![Furukawa electric S124 User Manual Download Page 97](http://html1.mh-extra.com/html/furukawa-electric/s124/s124_user-manual_2349549097.webp)
96
CAUTION
The V-groove is made of a brittle ceramic material. Clean the
V-groove carefully. DO NOT use any abrasive tools such as metal
to clean.
As Freon gas might contaminate camera lens, DO
NOT use a spray including Freon gas or alternatives
for cleaning.
Do not use a gas spray on the splicer.
The hazardous gas may come out by electric
discharge. It may cause a fire and machine failure.
7.2.6 Cleaning the Tight-holder and Fiber Holder
Keep the rubber and groove of the fiber holder clean. When they are dirty,
the fiber may be slippery during the tension test. Wipe the rubber and
groove with a lint-free tissue or a cotton bud soaked with denatured
alcohol. Clean the coating of fiber put on the holder, too.
Tight-Holder Fiber Holder
7.2.7 Exchange V-groove
It is possible to exchange the V-groove in case V-groove is damaged or
need special V-groove for special fibers.
Lid Pad
Rubber
Rubber
V-groove