![Furukawa electric S124 User Manual Download Page 45](http://html1.mh-extra.com/html/furukawa-electric/s124/s124_user-manual_2349549045.webp)
44
appropriate error message is displayed as below. ▼ key, an error massage will be
un-displaying and you will be able to see the state of fiber. Open the windshield, remove
the fibers after READY is displayed and retry the splice by repeating the entire procedure,
starting from the fiber preparation process. To ignore the error and continue the cycle,
press again.
6.3.1 Splicing Defects
Defects
Possible Cause
Action
Bubbling
Wrong Fusion
Program selected
Select the correct Fusion Program,
and repeat fusion splicing.
Faulty cleave
Repeat fiber preparation and fusion
splicing.
Dirty fiber end
Repeat fiber preparation and fusion
splicing.
Degradation of
electrodes
Replace the electrodes.
Not spliced
or
Neck-down
Wrong Fusion
Program selected
Select the correct Fusion Program,
and repeat fusion splicing.
Bad cleave
Repeat fiber preparation and fusion
splicing.
Excessive arc current
Perform an arc check to adjust arc
power.
Insufficient fiber feed Adjust the fiber feed amount.
Degradation of
electrodes
Replace the electrodes.
After splicing, the splicer inspects the splice state by image
processing. However, please also check the image by viewing it
on the LCD screen.
For the cause or countermeasure of Error, see “Splicing Defects”
on page 5.2.5.