![Furukawa electric S124 User Manual Download Page 61](http://html1.mh-extra.com/html/furukawa-electric/s124/s124_user-manual_2349549061.webp)
60
Parameter Table for Heater Program
Parameter
Unit
Description
1
st
Heat Temp IN
°C
Temperature of INNER heater for the first half.
1
st
Heat Temp OUT
°C
Temperature of OUTER heater for the first half.
1
st
Heat Duration
sec
Operation time of the first half.
2
nd
Heat Temp IN
°C
Temperature of INNER heater for The latter half.
2
nd
Heat Temp OUT
°C
Temperature of OUTER heater for The latter half.
2
nd
Heat Duration
sec
Heating time after 1
st
heating
Pre Heat Temp IN
°C
Temperature of INNER heater for preliminary heat
cycle. Preliminary heating temperature before the
first half.
Pre Heat Temp OUT
°C
Temperature of OUTER heater for preliminary heat
cycle. Preliminary heating temperature before the
first half.
Pre Heat Duration
sec
Operation time of preliminary heat cycle after the end
of cooling process or before the first half.
Cooling Temp
°C
Final temperature at the end of cooling process.
Cooling Duration
sec
Operation time of the cooling process.
Auto Start Heater
-
Setting for automatic start function.
OFF:Manual start operation.
ON : When the fiber set and left clamp is shut, heater
starts automatically.*
Quick Heating
-
Setting for sleeve pressing function.
OFF : Sleeve not pressed (Normal Mode).
ON : Sleeve pressed (Quick Mode).
*Do not leave the protection sleeve in the heater after the protector is
shrunk. The coating may melt.