NOTES:
1.
FOR COMPLETE INSTALLATION INSTRUCTIONS CONSULT FURNACE OPERATING MANUAL.
2.
INPUT LINES ARE SIZED FOR FEED LENGTHS OF 20 FEET OR LESS WITH 90 PSI MINIMUM AT SUPPLY MANIFOLD.
AN AIR REGULATOR AND FILTER ARE INSTALLED AT THE FURNACE. SIZE SUPPLY LINE AS FOLLOWS.
A. LESS THAN 35 SCFM: 1/2" SCH 40 OR SCH 80 PIPE
B. 35-90 SCFM: 3/4" SCH 40 OR SCH 80 PIPE
3.
CONNECT 3-PHASE POWER AT DISCONNECT SWITCH, #8 AWG - #4 AWG WIRE SIZE.
EQUIPMENT SPECIFICATIONS
NUMBER OF LAMPS
28
NUMBER OF HEATING ZONES
3
FURNACE HEATING CHAMBER LENGTH
30 in
(762 mm)
FURNACE BELT WIDTH (LAMP LENGTH)
9 in
(229 mm)
PRODUCT HEIGHT (MAX)
4 in
(102 mm)
ENTRANCE INTERFACE ROLLER
INCLUDED OPTION
EXIT INTERFACE ROLLER
INCLUDED OPTION
EDGE HEAT
SINGLE, ZONES 1-3
LINE VOLTAGE
380 Vac, 50 Hz, 3 Ph
APPROX NET WEIGHT
1600 LB
(726 kg)
EQUIPMENT RATING
TEMPERATURE
500 °C
400 °C
BELT SPEED
2-20 ipm
(5-50 cm/min)10 ipm
(25 cm/min)
POWER (PEAK & OPERATING)
24 kW
9 kW
CURRENT (BALANCED LOAD)
36 A
14 A
PROCESS GAS & EXHAUST
Replenishment Rate
1.0 rep/min
2.0 rep/min
Temp
Pressure
Min Flow
Min Flow
Typical
Typical
°C
Psi
scfh
sL/m
scfh
sL/m
CDA SUPPLY
30
70
19
9.1
38
18.1
N2 SUPPPLY
30
70
192
90.7
384
181.0
TOTAL PROCESS GAS EXHAUST
211
99.7
423
199.0
FLOWRATE
1000 cfm
(1700 m3/h) 1000 cfm
(1700 m3/h)
TEMPERATURE
<104°F
(<40°C)
<104°F
(<40°C)
FLOWRATE
1000 cfm
(1700 m3/h) 1000 cfm
(1700 m3/h)
TEMPERATURE
<104°F
(<40°C)
<104°F
(<40°C)
STANDARD CONDITIONS
PRESSURE
14.7 psia
(101.3 kPa)
TEMPERATURE
70 °F
(21 °C)
MAX
TYPICAL
Typical
Minimum
CABINET EXHAUST -
CONTROLLED
ATMOSPHERE COOLING
CABINET EXHAUST -
HEATING CHAMBER
Actual Conditons
Summary of Contents for LA-309
Page 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Page 6: ...vi LA 309 Owner s Manual ...
Page 12: ...Contents xii LA 309 Owner s Manual ...
Page 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Page 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Page 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Page 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Page 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Page 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Page 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Page 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Page 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Page 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Page 114: ......
Page 115: ......
Page 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Page 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Page 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Page 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Page 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Page 183: ......
Page 184: ......
Page 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Page 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Page 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Page 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 201: ...Material Safety Data Sheets 7 15 Notes ...
Page 202: ...Section 7 7 16 Owner s Manual ...
Page 204: ...Section 8 Owner s Manual ...
Page 206: ...Section 8 Owner s Manual ...
Page 212: ...iv Operation and Troubleshooting ...
Page 214: ...vi Operation and Troubleshooting ...
Page 224: ...Page 10 Operation and Troubleshooting ...
Page 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Page 232: ...Section 8 Owner s Manual ...
Page 233: ......
Page 234: ...Section 8 Owner s Manual ...
Page 279: ...Section 8 Owner s Manual ...
Page 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Page 282: ...16 Notes ...