4)
PROCESS GAS.
For furnaces equipped with the Auto Gas Shutoff feature, the process gas valves
will close after COOL DOWN is finished. For complete shutdown, manually close process gas supply
valves, but only after COOL DOWN is complete.
5)
MAIN POWER.
The main power is not automatically disconnected from the furnace. If you wish to
disconnect the main power to the furnace, wait until steps 1-3 are complete before throwing the facility
power breaker.
2.4.7 Turn Off Furnace PC and Monitor
Shutdown of Windows XP or Windows 7 and the furnace computer is only required if you are
disconnecting facility power to the furnace.
1)
LOG OFF
. Using the PC mouse, go to the Security screen. Click your user name in the User List and
click Log-Off. Clicking on the Exit button will take you out of furnace operation mode when all zones
are below 100°C and the belt has stopped.
2)
SHUT DOWN
. From the Windows Desktop, select start, then select Shut Down. The computer will
Power OFF after the operating system closes all files.
2.4.8 Exit Furnace Program
1)
EXIT FROZEN PROGRAM
. Using the PC keyboard, press ALT-F4 to exit the active program.
2)
This method of closing the furnace program should only be used to exit a frozen program. It will
not affect the program running in the PLC. If still in Cool Down, the furnace will continue to run
until the Cool Down sequence is complete.
Note: If communication is lost to the PLC LCM4 controller, the furnace program will freeze. To
exit any frozen Windows® program, Press Alt-F4 on the keyboard.
2.4.9 Shut Down Considerations
The furnace should be shut down when more than an hour or two will elapse between production runs. A
shutdown conserves energy and prolongs the life of the furnace and elements. Follow the steps in sections
2.4.4 Cool Down or 2.4.5 Complete Shut Down for short duration shutdowns.
The furnace computer is often left running if the furnace is to be down for less than 2-3 days. Leaving the
computer on for longer period will not harm the system.
10-004 – 676-110000
2-11
Summary of Contents for LA-309
Page 5: ...10 004 676 110000 v WARRANTY Warranty goes here ...
Page 6: ...vi LA 309 Owner s Manual ...
Page 12: ...Contents xii LA 309 Owner s Manual ...
Page 20: ...Section 1 1 8 LA 309 Owner s Manual ...
Page 68: ...Section 3 3 28 LA 309 Owner s Manual ...
Page 70: ...Section 4 4 2 LA 309 Owner s Manual ...
Page 72: ...Section 4 4 4 LA 309 Owner s Manual ...
Page 98: ...Section 5 5 2 LA 309 Owner s Manual ...
Page 100: ...Section 5 5 4 LA 309 Owner s Manual ...
Page 106: ...Section 5 5 10 LA 309 Owner s Manual ...
Page 108: ...Section 5 5 12 LA 309 Owner s Manual ...
Page 110: ...Section 5 5 14 LA 309 Owner s Manual ...
Page 112: ...Section 6 6 2 LA 309 Owner s Manual ...
Page 114: ......
Page 115: ......
Page 126: ...Section 7 1 Fiberfrax Cements MSDS 042006 Owner s Manual ...
Page 139: ...MSDS 2 Fiberfrax Duraboard MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 140: ...Section 7 2 Fiberfrax Duraboard MSDS 042006 Owner s Manual ...
Page 153: ...MSDS 3 Fiberfrax Fibers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 154: ...Section 7 3 Fiberfrax Fibers MSDS 042006 Owner s Manual ...
Page 167: ...MSDS 4 Fiberfrax Papers MSDS 042006 MATERIAL SAFETY DATA SHEETS ...
Page 168: ...Section 7 4 Fiberfrax Papers MSDS 042006 Owner s Manual ...
Page 181: ...MSDS 5 Magnaform MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 182: ...Section 7 5 Magnaform MSDS 050406 Owner s Manual ...
Page 183: ......
Page 184: ......
Page 185: ...Section 7 6 RTU Silicone Red Hi Temp 042006 Owner s Manual ...
Page 186: ...MSDS 6 RTU Silicone Red Hi Temp 042006 MATERIAL SAFETY DATA SHEETS ...
Page 189: ...Section 7 7 Kaowool Insulation MSDS 050406 Owner s Manual ...
Page 190: ...MSDS 7 Kaowool Insulation MSDS 050406 MATERIAL SAFETY DATA SHEETS ...
Page 201: ...Material Safety Data Sheets 7 15 Notes ...
Page 202: ...Section 7 7 16 Owner s Manual ...
Page 204: ...Section 8 Owner s Manual ...
Page 206: ...Section 8 Owner s Manual ...
Page 212: ...iv Operation and Troubleshooting ...
Page 214: ...vi Operation and Troubleshooting ...
Page 224: ...Page 10 Operation and Troubleshooting ...
Page 231: ...9 1 Section 9 APPENDIX B 9 1 EC913 CALIBRATION REPORT 9 2 SERIES EC900 OXYGEN ANALYZERS ...
Page 232: ...Section 8 Owner s Manual ...
Page 233: ......
Page 234: ...Section 8 Owner s Manual ...
Page 279: ...Section 8 Owner s Manual ...
Page 281: ...MSDS MATERIAL SAFETY DATA SHEETS ...
Page 282: ...16 Notes ...