PL-PLUS C OWNER’S MANUAL

All Furman Classic Series Conditioners feature a rear rack BNC socket which will accept any 12 VAC (0.5A) gooseneck lamp assembly 
(such as the Furman GN-LED or GN-I).  Simply slide the BNC plug over the socket and rotate clockwise until the connector snaps into 
the locked position.  The rear rack lamp can be powered on or off with the rear light switch which is adjacent to the BNC connector.  

ON/OFF ROCKER SWITCH:

Furman’s Classic Series 15 amp capacity power switch is specifically designed to stand up to the enormous high inrush current 
demands of many power amplifiers.  When the top portion of the switch is pressed flush with the panel, power is present.

EXTREME VOLTAGE SHUTDOWN (EVS) INDICATOR:

The Extreme Voltage LED Indicator is normally off.  It is located to the left of the power switch, though during normal use it will NOT be 
lit.  

The Extreme Voltage indicator monitors a hazard common in the entertainment, remote broadcast, and AV contractor industries: wir-
ing faults.  For example: accidental connection to 208VAC where 120VAC is expected, or an open series neutral from a 208 to 240VAC 
electrical service. The Furman EVS circuit senses voltages that are so high that operation would be impossible and shuts the power 
down before damage can occur.  

Upon initially applying power to the PL-PLUS C, the Extreme Voltage indicator will illuminate to a bright red if the input voltage is 
above the extreme voltage cutoff.  When this occurs, power will not be applied to the PL-PLUS C’s outlets. If the unit has been operat-
ing with an acceptable input voltage and subsequently that voltage exceeds 140V, it will shut off power to the outlets and the Extreme 
Voltage LED will light.

NOTE:

 If the mains power is above the high cutoff voltage and has caused the EVS circuit to remove power from the PL-PLUS C’s out-

lets, it cannot restore power without the operator manually turning the unit off, then on again.  Avoid turning the unit back on without 
first checking the source of the problem and changing the AC source (if necessary).

PROTECTION OK INDICATOR:

Although the Furman SMP circuit assures virtually maintenance-free protection from transient voltage spikes and surges, nature has a 
way of occasionally creating electrical forces that are beyond the capabilities of ANY surge suppression device to absorb without some 
degree of damage (such as a direct lightning hit in an outdoor application).  In the rare instance that this occurs, the green “Protection 
OK” LED indicator (located to the right of the retractable light tubes), will not be illuminated.  If this happens, some level of protection 
from voltage surges will remain, but the PL-PLUS C’s clamping voltage rating will be compromised and the unit must be returned to 
Furman for service. 

NOTE:

 Furman’s Classic Series power conditioners do not compensate for high or low AC line voltage. If you frequently move your 

rack to different locations, derive power from generators, use very long extension cords, travel internationally, or are in an area prone 
to brownouts, you may benefit from the use of one of Furman’s AC Voltage Regulators.

MULTI-SEGMENT LED VOLT METER:  

This three-color, 20-LED bar-graph is an accurate, self-checking AC voltmeter that continually measures input AC voltage.  The meter 
reads from 90 to 128 volts in 2 volt increments.  The optimal range voltages are indicated in green, with moderate and extremely high 
or low voltages in yellow and red, respectively.  The voltmeter provides three special flashing patterns to indicate abnormal conditions:

(1)   If only the single left-most (beneath the 90V mark) LED flashes, the input voltage is marginally low. 

(2)   If all of the LED’s on the voltmeter flash, the input voltage is marginally high.  Power to the PL-PLUS C’s outlets  will remain unless  
        the incoming voltage rises above the Extreme Voltage Shutdown (EVS) cutoff voltage  (140 volts).
       
(3)   If none of the LED’s on the voltmeter are lit, and the Extreme Voltages LED indicator is illuminated, then the PL-PLUS C has shut  
        down power to its outlets because the input voltage is in a range considered extreme (in excess of 140 volts). 

TROUBLESHOOTING

1.) Symptom:

     No power to the AC outlets.

Possible Cause:

 The circuit breaker (located on the rear panel - adjacent to the AC inlet cord) has tripped due to excessive load.

Action Needed:

 Unplug one piece of equipment from the Furman conditioner and push the round reset tab into the circuit breaker  

                             bezel.

Summary of Contents for PL-PLUS C

Page 1: ......

Page 2: ......

Page 3: ...ALL CONTENT 2008 FURMAN ALL RIGHTS RESERVED PRINTED IN CHINA ENGLISH Page 4 FRAN AIS Page 10 ESPA OL Page 16 PL PLUS C OWNER S MANUAL PL PLUS C GUIDE DE L UTILISATEUR PL PLUS C MANUAL DEL PROPIETARIO...

Page 4: ...her designs offer clamping voltages that are well above 330 Vpk Furman s SMP clamps at 188 Vpk 133 VAC RMS even when tested with multiple 6000 Vpk 3000 amp surges This unprecedented level of protectio...

Page 5: ...articular attention to the condition of the cords and cables at the plugs and at the point where they exit your Furman conditioner To prevent risk of fire or injury damaged cords and cables should be...

Page 6: ...assures virtually maintenance free protection from transient voltage spikes and surges nature has a way of occasionally creating electrical forces that are beyond the capabilities of ANY surge suppres...

Page 7: ...od of five years from the date of purchase If the product does not conform to this Limited Warranty during the warranty period as herein above specified purchaser shall notify Furman of the claimed de...

Page 8: ...C peak 3 000 Amps 133 VAC RMS RESPONSE TIME 1 nanosecond MAXIMUM SURGE CURRENT 6 500 amps NOISE ATTENUATION 10 dB 10 kHz 40 dB 100 kHz 50 dB 500 kHz Linear attenuation curve from 0 05 100 Ohms line im...

Page 9: ...L front lamp dimmer convenience outlet dual pull out lamps status indicators master power switch 15 amp circuit breaker wall wart spacing for large transformers bnc lamp connector bnc lamp power switc...

Page 10: ...des pointes de tension transitoires impliquant le d mant lement de votre syst me Ce n est pas le cas avec le circuit SMP de Furman Les voltages transitoires nuisibles sont absorb s contraints et diss...

Page 11: ...s niveaux de tensions lev s Ne retirez pas le couvercle Confiez toujours l entretien des techniciens qualifi s Le symbole repr sentant un clair avec une t te de fl che indique qu il y a pr sence de te...

Page 12: ...sque la portion sup rieure de l interrupteur est ras du panneau il y a alimentation en courant INDICATEUR DE PROTECTION CONTRE LES SURTENSIONS EXTR MES EVS Le voyant DEL Extreme Voltage est normalemen...

Page 13: ...t branch au module filtre Furman et appuyez sur le bouton de remise en circuit dans la lunette du disjoncteur 2 Sympt me Les prises de courant ne re oivent pas d alimentation lectrique et l indicateur...

Page 14: ...ention anormale du produit ou contre les dommages ou d fauts issus d une mauvaise installation Furman annulera cette garantie sa discr tion si le produit a t modifi sans l autorisation crite de Furman...

Page 15: ...pe convenance prise de courant deux lampes r tractables indicateur de statut commutateur lectrique disjoncteur de 15A espac permettre l utilisation de transformateurs prise de bnc lampe bnc lampe comm...

Page 16: ...aje m ltiples transitorios que requieren el desmantelamiento de su sistema y la reparaci n del supresor de sobretensi n Esto no sucede con el SMP de Fur man Los voltajes transitorios perjudiciales se...

Page 17: ...s mbolo de rel mpa go terminado en flecha sirve para alertar sobre la presencia de voltaje peligroso no aislado dentro del gabinete del equipo y puede tener la suficiente magnitud como para considerar...

Page 18: ...a la izquierda del interruptor de encendido apagado aunque durante el uso normal NO est encendido El indicador Extreme Voltage controla un riesgo que es com n en las industrias de entretenimiento tra...

Page 19: ...cnico 3 S ntoma El indicador de voltaje extremo EVS est encendido Causa posible El voltaje de entrada est por encima de los 140V y se cort la energ a en las salidas de la unidad Adem s si el voltaje...

Page 20: ...xclusiva de Furman ser reparar o reemplazar el producto defectuoso de la manera y durante el per odo que se establecen anteriormente Furman no tendr ninguna otra obligaci n con respecto a los producto...

Page 21: ...rriente para servicio dos l mparas retr ctiles indicadores de estado interruptor principal disyuntor de 15A amplio espacio para enchufar adaptadores de ca conector bnc para la lampara interruptor del...

Page 22: ...22 PL PLUS C OWNER S MANUAL Notes...

Page 23: ...23 FRAN AIS ENGLISH Espa ol Notes...

Page 24: ...1690 Corporate Circle Petaluma California USA 94954 Phone 877 486 4738 Fax 707 763 1310 www FurmanSound com PL PLUSC_RevA...

Reviews: