Specifications
Models ICS/ICX/FB
9.5
10
15
20
25
30
Boiler Connections
N. Steam Outlet 15 PSI
N/A
1.5”
2”
3”
3”
3”
NPT
NPT CL150# CL150#
CL150#
Flange Flange
Flange
N. Steam Outlet 150 PSI
1”
1”
1.25”
1.5”
2”
2”
NPT
NPT
NPT
NPT
NPT
NPT
O. Safety Valve Outlet 15 PSI
IN
N/A
0.75
1
1.5
1.5
1.5
MM
19
32
38
38
38
O. Safety Valve Outlet 150 PSI+
IN
1
1
1
1
1
1
(9.5 HP 100 PSI)
MM
25
25
25
25
25
25
P. Safety Valve Inlet 15 PSI++
IN
N/A
0.75
1
1.25
1.25
1.25
MM
19
25
32
32
32
P. Safety Valve Inlet 150 PSI
IN
0.75
0.75
0.75
0.75
0.75
0.75
(9.5 HP 100 PSI)
MM
19
19
19
19
19
19
Q. Feedwater Inlet
IN
1
1
1
1
1
1
MM
25
25
25
25
25
25
R. Blowdown Outlet
IN
1
1
1
1.25
1.25
1.25
MM
25
25
25
32
32
32
S. Water Column Blowdown
IN
1
1
1
1
1
1
MM
25
25
25
25
25
25
Ratings* (Sea level to 3000 ft.)
Output
1000 BTU/HR
318
335
503
670
838
1005
1000 KCAL/HR
80.1
84.4
127
169
211
253
Steam Output
LB/HR
328
345
518
690
863
1035
KG/HR
149
157
235
313
392
470
Approximate Fuel Consumption at Rated C++
Natural Gas (ICS)
FT3/HR
398
419
628
837
1047
1256
(9” - 13” w.c. req’d)
M3/HR
11.3
11.9
17.8
23.7
29.7
35.4
Natural Gas (ICX)
FT3/HR
384
403
606
807
1009
1210
(9” - 13” w.c. req’d)
M3/HR
10.8
11.4
17.2
22.9
28.6
34.3
Natural Gas Boiler
IN
1
1
1
1.25
1.25
1.5
Connection Size (Std CSD-1)
MM
25
25
25
32
32
38
Oil Inlet Size
IN
1/4
1/4
1/4
1/4
1/4
1/4
MM
6
6
6
6
6
6
Burner
3450 RPM/60 CY
Motor HP
2850 RPM/50 CY
.75
.75
1.5
1.5
1.5
1.5
Electric Power Requirements - Burner Only (in Amps) ***
120V,60 CY, 1 Phase
9.2
9.2
--
--
--
--
240V, 50/60 CY, 1 Phase
4.6
4.6
8.9
8.9
8.9
8.9
208V, 50/60 CY, 3 Phase
3.1
3.1
4.4
4.4
4.4
4.4
240V, 50/60 CY, 3 Phase
2.8
2.8
4.2
4.2
4.2
4.2
480V, 50/60 CY, 3 Phase
1.4
1.4
2.1
2.1
2.1
2.1
Water Content
U.S. GAL
16
24
39
77
82
170
LITERS
61
91
148
292
311
644
Specifications and Dimensions are approximate. We reserve the right to change specifications and/or dimensions..
+
High pressure boilers purchased with low pressure
openings may have larger than specified opening sizes, consult factory for correct opening sizes.
++
50 and 60 HP have two safety valves on low pressure.
+++
Consumption based on Natural Gas 1000 BTU/ft.
3
.
*
All ratings from 0 PSIG and at 212 degrees F.
***
Control circuit electrical requirement will vary with the system
voltage, please consult factory.
--
Consult factory.
ffsle-pds-2011-1223
The Fulton Companies
972 Centerville Road
Pulaski, NY 13142
Call 315-298-5121
Fax 315-298-6390
www.fulton.com
10-G 1/01
Summary of Contents for FB-A 10
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ...2 G 1 01...
Page 9: ...Safety Warnings Precautions 1 3 G 1 01...
Page 10: ...4 G 1 01...
Page 12: ...6 G 1 01...
Page 13: ...7 G 1 01 Description Instructions LE...
Page 14: ...8 G 1 01...
Page 17: ...11 G 1 01 Operation LE...
Page 18: ...12 G 1 01...
Page 20: ...14 G 1 01...
Page 21: ...15 G 1 01 Maintenance LE...
Page 22: ...16 G 1 01...
Page 29: ...23 G 1 01 Parts LE...
Page 30: ...24 G 1 01...
Page 32: ...26 G 1 01...
Page 33: ...Boiler Description Instructions Gas Fired Boiler 2 27 G 1 01...
Page 37: ...30 G 1 01 Description Instructions I E K K J K D C H B A G F...
Page 50: ...42b G 1 01...
Page 51: ...43D G 1 01 Operation 3...
Page 52: ...43b G 1 01...
Page 59: ...Maintenance 4 5 G 1 01...
Page 60: ...51 G 1 01...
Page 73: ...Parts 5 6 G 1 01...
Page 88: ...79 G 1 01 Parts...
Page 90: ...81 G 1 01 Parts Gas Burner Ignition Assembly Gas Burner Components...
Page 95: ...Warranty 6 8 G 1 01...
Page 96: ...87 G 1 01...
Page 98: ...89 G 1 01...
Page 100: ...91 G 1 01...
Page 101: ...Component Data Sheets 7 G 1 01...
Page 102: ......