B
I
J
ON/OFF GAS HEAD
CAN PIVOT 360°
MODULATED GAS HEAD IS
FIXED ABOVE FAN HOUSING
CLEARANCE REQUIRED FOR
BURNER REMOVAL
E
Top View
Front View
Side View
K
P
N
F
A
M
S
H
R
Q
O
G
C
D
L
Standard Models ICS/FB-A
4
6
9.5
10
15
20
25
30
50
60
Models ICX/FB-F
4
6
9.5
10
15
20
25
30
Unit Size:
BHP
4
6
9.5
10
15
20
25
30
50
60
A.
Boiler Height
IN
47.5
57.5
67.5
63.5
69.5
72.5
75
82.5
87.5
93.5
MM
1207
1461
1715
1613
1765
1842
1905
2069
2223
2375
B.
Boiler Height With Trim*
IN
65
75
85
80.5
86.5
92.5
95
102
106.5
120
& Fuel Train Assembly
MM
1651
1905
2159
2045
2197
2350
2413
2591
2705
3048
C.
Overall Depth Stack
IN
44
44
44
46
47
58
59
67
78
78
to Burner Fan Housing
MM
1118
1118
1118
1168
1194
1474
1499
1702
1981
1981
D.
Boiler Diameter
IN
26
26
26
28
30
39
39
46
55
55
MM
660
660
660
710
760
990
990
1170
1400
1400
E.
Overall Width
IN
33
33
33
33.5
35.5
43
43
49
57
57
with Water Column
MM
838
838
838
851
902
1091
1091
1244
1448
1448
F.
Flue Outlet Diameter
IN
6
6
6
6
8
10
10
12
12
12
MM
152
152
152
152
203
254
245
305
305
305
G
. To Center of Flue Outlet
IN
42
52
62
58
63
66
68
73.5
79
85
MM
1070
1320
1575
1473
1600
1675
1728
1867
2007
2159
H.
Feedwater Inlet
IN
27
33
33.5
33
33.5
34
34
34
35
35
MM
685
840
851
840
851
865
865
865
890
890
I.
Handholes
IN
19
19
19
19
19
19
19
19
20
20
MM
485
485
485
485
485
485
485
485
510
510
J.
Blowdown Outlet
IN
15
15
15.5
15.5
15.5
16.5
16.5
16.5
17.5
17.5
MM
380
380
394
394
394
420
420
420
445
445
K.
Water Column Extension
IN
14
14
14
14
14
14
14
14
14
14
MM
355
355
355
355
355
355
355
355
355
355
L.
Gas Train Extension
IN
22.5
22.5
25
21.5
20.5
25
25
27
22.5
34
(CSD-1)
MM
572
572
635
546
521
635
635
686
572
867
M.
Clearance Required
IN
72
82
92
86
92
96
98
106
114
124
for Burner Removal*
MM
1828
2083
2337
2184
2337
2438
2490
2692
2896
3150
Weights
Approx. Shipping Weight
LB
1400
1700
1900
2000
2280
3400
3500
4780
6526
7280
KG
635
773
862
910
1036
1545
1591
2173
2966
330
Approx. Operating Weight
LB
1516
1833
2200
2200
2605
4042
4184
6197
8569
9531
KG
688
831
998
998
1182
1833
1898
2811
3887
4323
*This dimension is 6” less for oil fired units 4-50 HP and 12” less for oil fired units 60 HP.
NOTE:
Recommended minimum clearance is 24” to the side and back of unit; 36” in front
Dimensions
Fulton Gas & Oil Fired
Vertical Tubeless
Steam Boilers
(Standard Burner)
Product Data Submittal
Fulton Models: ICS/FB-A and ICX/FB-F
29a-G 1/01
Summary of Contents for FB-A 10
Page 2: ......
Page 4: ......
Page 6: ......
Page 8: ...2 G 1 01...
Page 9: ...Safety Warnings Precautions 1 3 G 1 01...
Page 10: ...4 G 1 01...
Page 12: ...6 G 1 01...
Page 13: ...7 G 1 01 Description Instructions LE...
Page 14: ...8 G 1 01...
Page 17: ...11 G 1 01 Operation LE...
Page 18: ...12 G 1 01...
Page 20: ...14 G 1 01...
Page 21: ...15 G 1 01 Maintenance LE...
Page 22: ...16 G 1 01...
Page 29: ...23 G 1 01 Parts LE...
Page 30: ...24 G 1 01...
Page 32: ...26 G 1 01...
Page 33: ...Boiler Description Instructions Gas Fired Boiler 2 27 G 1 01...
Page 37: ...30 G 1 01 Description Instructions I E K K J K D C H B A G F...
Page 50: ...42b G 1 01...
Page 51: ...43D G 1 01 Operation 3...
Page 52: ...43b G 1 01...
Page 59: ...Maintenance 4 5 G 1 01...
Page 60: ...51 G 1 01...
Page 73: ...Parts 5 6 G 1 01...
Page 88: ...79 G 1 01 Parts...
Page 90: ...81 G 1 01 Parts Gas Burner Ignition Assembly Gas Burner Components...
Page 95: ...Warranty 6 8 G 1 01...
Page 96: ...87 G 1 01...
Page 98: ...89 G 1 01...
Page 100: ...91 G 1 01...
Page 101: ...Component Data Sheets 7 G 1 01...
Page 102: ......