Section VIII. Lens Replacement & Calibration
Lens Removal and Replacement:
If you wish to change the lens, the machine must be calibrated again. Ensure lenses are probably stored with appropriate
lens caps and are not cross threaded when mounting.
1.
Ensure laser head is in a reachable position to remove lens.
2.
Remove any objects or work pieces from underneath the lens work area.
3.
Place the lens cap onto your lens to protect the lens from potential damage.
4.
Carefully twist counter-clockwise to loosen the lens.
Try to avoid damaging the camera or camera shutter located on the side of the scanhead.
Avoid touching the glass surface of the lens to prevent scratches. The lens collar may come loose with
the lens,if that occurs remove both together and separate once dismounted.
5.
Replace the collar to the scanhead before inserting a new lens.
Lens
Lens Collar
Camera
Fig. 28
Fig. 29
7.
Remove top and bottom protective lens caps and screw new lens into collar on scan head.
DO NOT OVERTIGHTEN LENS!!
8.
Wipe down the glass surfaces with optical lens wipes if you notice smudges, fingerprints or other
contaminants.