background image

9

RISK OF FIRE

Hazard 

What could happen

How to prevent it

Attempting to fill 
the fuel tank while 
the engine  
is running

Fuel and fuel vapours can 

become ignited by coming in 

contact with hot components 

such as the muffler, engine 

exhaust gases, or from an 

electrical spark.

Turn engine off and allow it to 

cool before adding fuel to the 

tank. Equip area of operation 

with a fire extinguisher certified 

to handle fuel fires.

Sparks, fire, hot 
objects

Cigarettes, sparks, fires, or other 

hot objects can cause fuel or 

fuel vapours to ignite.

Add fuel to tank in well 

ventilated area. Make sure there 

are no sources of ignition near 

the generator.

Improper storage 
of fuel

Improperly stored fuel could 

lead to accidental ignition. Fuel 

improperly secured could get 

into the hands of children or 

other unqualified persons.

Store fuel in an approved 

container designed to hold 

fuel. Store container in secure 

location to prevent use by 

others.

Tampering with 
factory set engine 
speed settings

Engine speed has been factory 

set to provide safe operation. 

Tampering with the engine 

speed adjustment could result in 

overheating of attachments and 

could cause a fire.

Never attempt to “speed-up” 

the engine to obtain more 

performance. Both the output 

voltage and frequency will 

be thrown out of standard by 

this practice, endangering 

attachments and the user.

Inadequate 
ventilation for 
generator

Materials placed against or near 

the generator or operating the 

generator in areas where the 

temperature exceeds 40° C. 

ambient (such as storage rooms 

or garages) can interfere with 

its proper ventilation features 

causing overheating and 

possible ignition of the materials 

or buildings.

Operate generator in a clean, 

dry, well ventilated area. 

DO NOT OPERATE UNIT 

INDOORS  OR IN ANY 

CONFINED AREA.

Overfilling the fuel 
tank - fuel spillage

Spilled fuel and its vapours 

can become ignited from hot 

surfaces or sparks.

Use care in filling the tank to 

avoid spilling fuel. Make sure 

fuel cap is secured tightly and 

check engine for fuel leaks 

before starting engine. Move 

generator away from refuelling 

area or any spillage before 

starting engine. Allow for fuel 

expansion. Never refuel with 

the engine running.

Summary of Contents for SD2200i

Page 1: ...APABLITY USB PORT INVERTER GENERATOR INSTRUCTION MANUAL WARNING Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock Fire and or s...

Page 2: ...ted 2200W Max DC output 12V 8 0Amp USB output 5V 1 5Amp L x W x H 500 x 285 x 455mm Net Weight 21kg Gross Weight 24kg 1 Fuel cap 2 Fuel cap lever 3 Spark plug socket 4 Control panel 5 Recoil starter 6...

Page 3: ...3 KNOW YOUR PRODUCT cont...

Page 4: ...02 INTRODUCTION Page 05 SAFETY INSTRUCTIONS Page 05 EXPLANATION OF RISKS Page 08 PRE OPERATION CHECK Page 12 OPERATION Page 14 MAINTENANCE Page 21 TRANSPORTING STORAGE Page 25 TROUBLE SHOOTING Page 26...

Page 5: ...ge SAFETY INSTRUCTIONS ELECTRICAL SAFETY Read and understand the manual prior to operating this tool Save these instructions and other documents supplied with this tool for future reference The petrol...

Page 6: ...t away from buildings or other equipment during operation ALWAYS operate generator a minimum of 2 meters from any conductive surface eg metals Persons who are fitted with a heart pacemaker or similar...

Page 7: ...The inverter generator is fitted with Earth 23 that may reduce the risk of electrocution in certain applications Always consult a qualified electrician before connecting the grounding terminal or whe...

Page 8: ...well ventilated area Make sure hands are dry before touching unit Placing generator on or against highly conductive surface such as a steel walkway or metal roof Accidental leakage of electrical curre...

Page 9: ...speed has been factory set to provide safe operation Tampering with the engine speed adjustment could result in overheating of attachments and could cause a fire Never attempt to speed up the engine t...

Page 10: ...rator components Contact with hot surfaces such as engines exhaust components could result in serious burns During operation touch only the control surfaces of the generator Keep children away from th...

Page 11: ...peration and controls of the generator Know how to shut it off quickly Equip area of operation with a fire extinguisher certified to handle gasoline or fuel fires Keep children or others away from the...

Page 12: ...it registers on the top mark of the dipstick Fig 6 Use premium quality 4 stroke engine oil SAE10W30 recommended oil for Australia and New Zealand Note The Oil Alert System will automatically stop the...

Page 13: ...ed Petrol Do not overfill the fuel tank Fig 10 Do not use ethenol blended fuels 5 After refuelling make sure the fuel cap 1 is closed properly and securely 6 Fuel stabiliser to be used at all times OV...

Page 14: ...14 Fig 13 2 Hold the carrying handle firmly with one hand With the other hand pull slightly on the rip cord 5 until you feel resistance and then pull hard and swiftly on the cord Fig 13 Do not let th...

Page 15: ...is turned ON the engine will automatically enter idle mode after an electrical appliance has been disconnected It will return to the proper speed required when the appliance is connected Having the E...

Page 16: ...ht will stay on and power will no longer be supplied to connected electronic devices How to Correct 1 Disconnect any electronic devices then stop the engine 2 Reduce the total wattage of connected ele...

Page 17: ...overload indicator section on the previous page Fig 27 AC Electric lamps Power tools Electromotor DC battery Power factor 1 0 8 0 9 0 4 0 7 Efficiency 0 85 Rated voltage 12V Rated current 8A 0 2000W...

Page 18: ...DC USB BATTERY POWER OVERLOAD RUN LOW OIL STOP ECONOMY ON ON OFF 240V OFF STOP START ON REMOTE CONTROL 12V DC 8 3A 12 V APPLIANCE OUTLET 8 3A 5V DC USB BATTERY POWER OVERLOAD RUN LOW OIL STOP ECONOMY...

Page 19: ...tarting the generator 3 Connect the DC cable 19 to battery charging outlet 15 Fig 33 The battery will begin charging 4 When disconnecting remove the plug from the generator before unclipping the clamp...

Page 20: ...dure 1 Shut off all loads and unplug electrical loads from generator panel receptacles 2 Let engine run at no load for several minutes to stabilize internal temperatures of engine and generator 3 Rota...

Page 21: ...must be run make sure the area is well ventilated The exhaust contains poisonous carbon monoxide gas CAUTION Use authorized parts or their equivalent The use of replacement parts which are not of equ...

Page 22: ...casing Remove the crankcase dipstick Place an oil pan underneath the engine Tilt generator to collect used oil Allow oil to drain completely Return generator to a level surface Crankcase Dipstick hol...

Page 23: ...nnect the spark plug wire from the spark plug Before removing the spark plug clean the area around its base to prevent debris from entering the engine Insert a spark plug socket wrench through the ope...

Page 24: ...tighten the screws Allow hot components to cool before touching WARNING Avoid contacting hot areas of this unit Remove screws then remove shown area of outer casing Check the muffler screen and spark...

Page 25: ...sport the generator on a rough road drain the fuel from the generator beforehand Take care not to drop or strike the generator when transporting Do not place heavy objects on the generator Before stor...

Page 26: ...ating oil Add good quality oil Is there fuel in the carburettor Start a few times to ensure that fuel enters the carburettor Is the spark plug working Replace spark plug Contact TPE customer service y...

Page 27: ...r local council authority for recycling advice Read instruction manual Extremely hot surface Do not touch a hot muffler or exhaust system You may get burned These parts get extremely hot from operatio...

Page 28: ...s liability shall be deemed void if the machine is modified in any way and the manufacturer shall therefore accept no liability for any damages arising as a result of modifications 1 x SD2200i Invert...

Page 29: ...29...