Model name Waterstage SHP
16
TRI 15
TRI 17
Rated heating performances
(outdoor temp. / flow temp.)
Heat output
+7°C/+35°C - Underfloor heating system
kW
16.00
15.00
17.00
-7°C/+35°C - Underfloor heating system
kW
14.50
13.20
15.00
+7°C/+55°C - Radiator
kW
14.50
13.20
15.00
-7°C/+55°C - Radiator
kW
10.90
13.20
14.20
Power consumption
+7°C/+35°C - Underfloor heating system
kW
3.86
3.46
4.10
-7°C/+35°C - Underfloor heating system
kW
5.27
4.55
5.32
+7°C/+55°C - Radiator
kW
5.58
4.77
5.49
-7°C/+55°C - Radiator
kW
5.89
6.77
7.40
Coefficient of performance (COP) (+7°C/+35°C)
4.15
4.33
4.15
Electrical specifications
Electrical voltage (50 HZ)
V
230
400
400
Maximum current for appliance
A
28
14
14
Nominal current
A
17.2
6.43
7.4
Maximum current of the Heating system electrical backup
A
26.1
39
39
Power of the Heating system electrical backup
kW
6 kW
(single phase)
9 kW
(3-phase)
9 kW
(3-phase)
Circulation pump actual power consumption
W
39.5
39.5
39.5
Maximum power consumed by the outdoor unit
W
6300
6770
7400
Hydraulic Circuit
Maximum operating pressure
MPa (bar)
0.3 (3)
0.3 (3)
0.3 (3)
Available heating pressure at nominal point +7°C / +55°C (
Δt8)
MPa (bar)
0.05 (0.5)
0.055 (0.55)
0.045 (0.45)
Minimum allowed hydraulic flow rate
l/h
600
600
600
Miscellaneous
Weight of outdoor unit
Kg
137
138
138
Noise level at 5 m
1
(Outdoor unit)
dB (A)
45
45
45
Sound power level in accordance with EN 12102
2
(Outdoor unit)
dB (A)
67
67
67
Weight of hydraulic unit (empty / full of water)
Kg
53 / 75
53 / 75
53 / 75
Hydraulic unit water capacity
l
30
30
30
Noise level at 1 m
1
(Hydraulic unit)
dB (A)
37
37
37
Sound power level in accordance with EN 12102
2
(Hydraulic unit)
dB (A)
45
45
45
Heating system operating limits
Outdoor temperature min/max
°C
-25 / +35
-25 / +35
-25 / +35
Max. heating water flow temperature underfloor heating
°C
45
45
45
Max. heating water flow temperature low temperature radiator
°C
60
60
60
Min. flow water temperature
°C
8
8
8
Refrigeration circuit
Gas pipe diameters
Inches
5/8
5/8
5/8
Liquid Piping Diameters
Inches
3/8
3/8
3/8
Factory fill of refrigerant R410A
3
g
3800
3800
3800
Maximum operating pressure
MPa (bar)
4.15 (41.5)
4.15 (41.5)
4.15 (41.5)
Minimum / Maximum length of pipes
4 / 6
m
5 / 15
5 / 15
5 / 15
Maximum length of pipes
5
m
30
30
30
Maximum level difference
(Outdoor unit over hydraulic unit and heating only / Other cases)
m
25 / 15
25 / 15
25 / 15
►
General characteristics
1
Sound pressure level at (x) m from the appliance, 1.5m off the ground, open field
directionality 2.
2
The sound power level is a laboratory measurement of the emitted sound power. It
does not correspond to a measurement of the perceived sound power.
3
Refrigerant R410A as per NF EN 378.1 standard.
4
Filling with refrigerant R410A is done at the factory.
5
Taking into account a possible additional fill of refrigerant R410A (see
"Additional
filling", page 28)
.
6
The announced thermal and acoustic performances are measured with 7.5m length
refrigerant lines.
Waterstage / Installation / 2011 - EN