En-4
2.4. Accessories
The following installation accessories are supplied. Use them
as required.
Name and Shape
Q’ty
Name and Shape
Q’ty
Operating Manual
1
Drain hose insulation
1
Installation Manual
(This manual)
1
Cloth tape
1
Wall hook bracket
1
Tapping screw (big)
8
Remote
controller
1
Tapping screw
(small)
2
Battery
2
Air cleaning filter
2
Remote
controller
holder
1
Air cleaning filter
frame
2
The following items are necessary to install this air condi-
tioner. (The items are not included with the air conditioner
and must be purchased separately.)
Name
Q’ty
Connection pipe assembly
1
Connection cable (4-conductor)
1
Wall pipe
1
Decorative tape
1
Vinyl tape
1
Wall cap
1
Saddle
1 set
Drain hose
1
Tapping screws
1 set
Sealant
1
M10 bolt, nut
4 set
1
2.5. Optional parts
3. GENERAL
This INSTALLATION MANUAL briefly outlines where and how to
install the air conditioning system. Please read over the entire set of
instructions for the indoor and outdoor units and make sure all ac-
cessory parts listed are with the system before beginning.
]1
3.1. Type of copper pipe and insulation material
CAUTION
Refer to the installation manual for the outdoor unit for
description of allowable pipe length and height difference.
3.1.1. SINGLE TYPE INSTALLATION
MODEL
Diameter
Liquid pipe
Gas pipe
18,000BTU/h model
9.52mm (3/8in.)* 15.88mm (5/8in.)*
24,000BTU/h model
9.52mm (3/8in.)* 15.88mm (5/8in.)
* When single type installation, the ADAPTER included outdoor
unit is necessary to connect the indoor unit to the outdoor unit.
3.1.2. MULTI TYPE INSTALLATION
MODEL
Diameter
Liquid pipe
Gas pipe
18,000BTU/h model
6.35mm (1/4in.)
12.70mm (1/2in.)
24,000BTU/h model
6.35mm (1/4in.)
15.88mm (5/8in.)
CAUTION
Install heat insulation around both the gas and liquid pipes.
Failure to do so may cause water leaks.
Use heat insulation with heat resistance above 248 °F.
Reverse cycle model only
In addition, if the humidity level at the installation location
of the refrigerant piping is expected to exceed 70%, install
heat insulation around the refrigerant piping. If the expected
humidity level is 70-80%, use heat insulation that is 15 mm
(19/32 in.) or thicker and if the expected humidity exceeds
80%, use heat insulation that is 20 mm (25/32 in.) or thicker.
If heat insulation is used that is not as thick as speci
fi
ed,
condensation may form on the surface of the insulation.
In addition, use heat insulation with heat conductivity of
0.045 W/(m•K) or less (at 68 °F).
]1
3.2. Additional materials required for installation
A. Refrigeration (armored) tape
B. Insulated staples or clamps for connecting wire
(See your local electrical codes.)
C. Putty
D. Refrigeration lubricant
E. Clamps or saddles to secure refrigerant piping
Model No.
Parts name
Application
Wired Remote
Controller
UTY-
RNNUM
For air conditioner
operation
Wireless Remote
Controller
UTY-
LNHUM
For air conditioner
operation
For air conditioner
operation
Simple Remote
Controller
UTY-
RSNUM
For control input/output
port
External connect
kit
UTY-
XWZX
Refer to each installation manual for the method of installing
optional parts.