Table
4-6
Types
of
maintenance
for
SPARC
M10-4S
(continued)
Supported:
Maintenance
can
be
performed
/
Unsupported:
Maintenance
cannot
be
performed
FRU
Active/hot
Active/cold
Inactive/hot
Inactive/cold
(*1)
System
stopped
Reference
Operation
panel
Unsupported Supported
(*2)
Unsupported Supported
Supported
*1:
For
a
single-chassis
configuration,
the
inactive/cold
maintenance
procedure
is
the
same
as
that
for
stopping
the
system,
therefore
see
the
procedure
for
system-stopped
maintenance.
*2:
It
is
necessary
to
use
dynamic
reconfiguration
(DR)
to
disconnect
a
chassis
requiring
maintenance
from
the
physical
partition.
*3:
Active/hot
replacement
can
be
performed
only
with
a
redundant
configuration.
*4:
The
types
of
maintenance
for
internal
disks
are
different
from
those
of
other
FRUs.
For
details,
see
*5:
The
types
of
maintenance
for
PCIe
cards
are
different
from
those
of
other
FRUs.
For
details,
see
Table
4-7
Types
of
maintenance
for
crossbar
box
Supported:
Maintenance
can
be
performed
/
Unsupported:
Maintenance
cannot
be
performed
FRU
Active/hot
Active/cold
Inactive/hot
Inactive/cold
System
stopped
Reference
Crossbar
unit
Unsupported Unsupported Unsupported Unsupported Supported
(*2)
XSCF
unit
Supported
(*3)
Unsupported
(*1)
Supported
Unsupported
(*1)
Supported
(*2)
Power
supply
unit
Supported
(*4)
Unsupported
(*1)
Supported
Unsupported
(*1)
Supported
(*2)
Fan
unit
Supported
Unsupported
(*1)
Supported
Unsupported
(*1)
Supported
(*2)
XSCF
interface
unit
Unsupported Unsupported
(*1)
Unsupported Unsupported
(*1)
Supported
(*2)
Crossbar
backplane
unit
Unsupported Unsupported
(*1)
Unsupported Unsupported
(*1)
Supported
(*2)
Fan
backplane
Unsupported Unsupported
(*1)
Unsupported Unsupported
(*1)
Supported
(*2)
Operation
panel
Unsupported Unsupported
(*1)
Unsupported Unsupported
(*1)
Supported
(*2)
*1:
If
any
physical
partition
is
currently
operating,
the
crossbar
box
cannot
be
powered
off.
*2:
All
the
physical
partitions
must
be
powered
off,
and
the
system
must
be
completely
shut
down.
*3:
The
XSCF
must
be
configured
as
a
slave
before
maintenance
is
started.
If
the
XSCF
is
operating
as
the
master
XSCF,
switch
it
to
a
standby
XSCF.
*4:
Active/hot
replacement
can
be
performed
only
with
a
redundant
configuration.
Table
4-8
Types
of
maintenance
for
cables
and
dedicated
power
distribution
unit
Supported:
Maintenance
can
be
performed
/
Unsupported:
Maintenance
cannot
be
performed
FRU
Active/hot
Active/cold
Inactive/hot
Inactive/cold
System
stopped
Reference
Crossbar
cable
(electrical)
Unsupported Unsupported Unsupported Supported
Supported
Crossbar
cable
(optical)
Unsupported Unsupported Unsupported Supported
Supported
Chapter
4
Preparing
for
Maintenance
51
Summary of Contents for SPARC M10-4
Page 20: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 xx ...
Page 34: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 10 ...
Page 56: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 32 ...
Page 94: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 70 ...
Page 110: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 86 ...
Page 264: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 240 ...
Page 290: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 266 ...
Page 306: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 282 ...
Page 328: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 304 ...
Page 338: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 314 ...
Page 382: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 358 ...
Page 394: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 370 ...
Page 416: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 392 ...
Page 440: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 416 ...
Page 468: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 444 ...
Page 480: ...Fujitsu M10 4 Fujitsu M10 4S SPARC M10 4 SPARC M10 4S Service Manual February 2014 456 ...