Servicing Motherboard Components
117
▼
Remove the SCC Module
1. Remove the PCIe/XAUI riser 2.
See
“Remove a PCIe/XAUI Riser” on page 105
2. Locate the SCC module.
3. Pull the SCC module straight up from its connector.
Related Information
■
“SCC Module Overview” on page 116
■
“Install the SCC Module” on page 117
▼
Install the SCC Module
1. Unpack the replacement SCC module and set it on an antistatic mat.
2. Align the SCC module with its connector on the motherboard.
Note –
The SCC module and its connector are keyed.
3. Press the SCC module down until it seats.
4. Install PCIe/XAUI riser 2.
See
“Install a PCIe/XAUI Riser” on page 107
5. Install the top cover.
See
“Install the Top Cover” on page 177
.
6. Slide the server into the rack.
See
“Reinstall the Server in the Rack” on page 178
7. Connect the power supplies.
“Connect Power Cords to the Server” on page 181
Note –
As soon as the power cords are connected, standby power is applied.
Depending on how the firmware is configured, the system might boot at this time.
8. Power on the server.
See
“Power On the Server Using the
or
On the Server Using the Front Panel Power Button” on page 182