SPARC Enterprise T5140 and T5240 Servers Service Manual • July 2009
3. If necessary, review the PCIe and XAUI card guidelines to plan your
installation.
See
“PCIe and XAUI Card Reference for SPARC Enterprise T5140 Servers” on
for additional information.
4. Remove the PCIe/XAUI riser board.
See
“Remove a PCIe/XAUI Riser” on page 105
5. Remove the PCI filler panel.
■
SPARC Enterprise T5140 servers: PCIe filler panels are located in the removable
PCI cross beam. Press the filler panel in from the rear until it snaps into place,
as shown in the following figure.
FIGURE:
Installing a PCIe Card (SPARC Enterprise T5140)
■
SPARC Enterprise T5240 servers: PCIe filler panels are located on the riser
board assembly. Press the filler panel in from the rear until it snaps into place as
shown in the following figure.