Identifying FRUs in SPARC Enterprise T5140 Servers
189
The following table identifies the power distribution and fan module components in
the server and points to instructions for servicing them.
TABLE:
Power Distribution/Fan Module Components (SPARC Enterprise T5140 Servers)
Item
FRU
Replacement Instructions
Notes
FRU Name (If Applicable)
Air duct
“Remove the Air Duct”
on page 103
“Install the Air Duct” on
page 104
Must be installed to
provide proper cooling
to the system.
N/A
Power distribution
board/bus bar
“Servicing Power
Distribution Boards” on
page 163
Bus bar is attached to the
PDB with four screws.
If replacing a defective
PDB, you must move the
bus bar to the new board
and program the chassis
serial number using the
setscn
command.
/SYS/PDB
Paddle card
“Servicing Paddle
Cards” on page 174
Includes the top cover
interlock switch.
/SYS/CONNBD
Fan power boards
“Servicing Fan Power
Boards” on page 148
Must be removed to
service the paddle card.
/SYS/FANBD0
/SYS/FANBD1
Power supplies
“Servicing Power
Supplies” on page 135
Two power supplies
provide N+1
redundancy.
/SYS/PS0
/SYS/PS1
Fan modules
“Servicing Fan Modules”
on page 129
At least six fan modules
must be installed in the
server.
*
* The service processor checks for proper fan module configuration, and issues a service warning if a fan module is missing or inserted
into an unsupported slot.
/SYS/FANBD0/FM0
/SYS/FANBD0/FM1
/SYS/FANBD0/FM2
/SYS/FANBD0/FM3
†
/SYS/FANBD1/FM0
/SYS/FANBD1/FM1
/SYS/FANBD1/FM2
/SYS/FANBD1/FM3
‡
† A fan module might not be present in this slot for some configurations.
‡ A fan module might not be present in this slot for some configurations.
Summary of Contents for SPARC Enterprise T5140
Page 1: ......
Page 2: ......
Page 6: ......
Page 82: ...56 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 154: ...128 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 234: ...208 SPARC Enterprise T5140 and T5240 Servers Service Manual July 2009 ...
Page 239: ......
Page 240: ......