background image

U41182-J-Z126-1-74

61

Standard processing in SVP mode

User frames and subframes

FACILITY =>

Possible displays of memory areas with various
addresses:

L

LOGICAL

logical storage address

R

REAL

real storage address

P

P-VIRTUAL

primary virtual storage address

S

S-VIRTUAL

secondary virtual storage address

ABS

absolute address

KEY

memory protect key

V

A-VIRTUAL

address space virtual address

I

H-VIRTUAL

basic address space virtual address

ADRS =>

Memory address

XXXX

address space larger than 32 bits

XXXXXXXX

32-bit address

Special key functions

When you press this key, the following subframe is displayed:

Figure 32: ALTER/DISPLAY FRAME screen (subframe)

By making the appropriate entries and pressing the

key, you can use this frame to

change and display the contents of important CPU registers. It is a requirement that the
selected CPU (

key) is stopped beforehand (see “(ML) MODE SELECTION FRAME” on

page 48).

P9

                      ----- ALTER/DISPLAY FRAME ----            E40L51G
 FUNCTION =>
  *A ALTER
  *D DISPLAY
 FACILITY =>
 -- REGISTER --
  *GR    *PSW
  *CR    *FCR
  *FPR   *PRX
  *AR

  *XCR
  *EX EPRX

 ADRS=>
     =>

                                                                  *PF9 CHANGE
                                                                       FACILITY
                CL-0       CPU-0 CHP-0        RUN
                                                           M
                                                   FLAG CODE = D90557 3 00000I00
 RA                        M                                []-[]00

ENTER

P16

Summary of Contents for S120 Series

Page 1: ... via front end processors The service processor SVP and the external 3970 SKP service console processor support common operation monitoring diagnosis and maintenance of the computer as well as TELESERVICE Like all computers in the 7 500 system family and the S1xx server series the S120 Business Server uses the BS2000 operating system in either dialog online teleprocessing OLTP or batch mode This o...

Page 2: ...ecified number refers is listed under that number at the back of the manual in the related publications section accompanied by a brief description A keyword index at the end of the manual helps you to find the relevant information quickly 1 3 Notational conventions Some text passages are marked using the following symbols Information that is particularly important for the function of the product I...

Page 3: ...ctive measures at his or her own cost The devices generate and emit high frequency energy If the devices are installed and used other than as instructed in the manual failures in the devices or other electric systems may occur If failures of this type occur it is the task of the user to carry out measurements and implement measures to solve the problem Only the cables supplied with the system or r...

Page 4: ... EMERGENCY POWER OFF and contact our service department Figure 1 UNIT EMERGENCY POWER OFF switch on the S120 The systems may only be installed by authorized trained personnel The cables must be laid in such a way that there is no danger of anyone tripping over them and they cannot be damaged Data transmission lines must not be connected or disconnected during electrical storms Ensure that no forei...

Page 5: ...d out by authorized and trained personnel All areas which are secured by locks or can only be opened using tools are maintenance areas and may only be accessed by trained personnel Unauthorized opening of the maintenance area and improper repairs can be dangerous for the user electric shock danger of fire ...

Page 6: ...Eine Dokuschablone von Frank Flachenecker by f f 1992 ...

Page 7: ...guration levels and the configuration of the S120 Business Server series and the concept of system operation Figure 2 S120 Business Server with additional cabinet The S120 Business Server consists of a cabinet plus an additional cabinet for channel expansions S120 Business Server ...

Page 8: ...nstallation The S120 models can have multiple channel groups Thus a reconfiguration is possible for these models if there is a partial failure Figure 3 Hardware overview of the S120 Business Server system with 3970 SKP Model Number of processors Performance factor S120 B 1 processing unit 1 0 S120 C 1 processing unit 1 4 S120 D 1 processing unit 1 7 S120 E 1 processing unit 2 0 ATOP TELESERVICE V ...

Page 9: ...SINIX 2000 V7 5 V8 0 1 manual The following section lists the most important hardware and software components for S120 operation 3 2 1 Hardware Figure 4 Hardware of the system S120 Business Server V7 Radio controlled clock serial V 24 SVP S120 I O channel SKP LAN Console ATOP serial CPU on off facility internal LAN serial Secondary console GTS Remote operator terminal ...

Page 10: ...3970 SKP screen and remote secondary consoles the SINIX system of the 3970 SKP the SVP of the S120 the BS2000 running on the S120 consoles for up to 7 VM2000 guest systems BS2000 applications via 9750 emulation Automatic Operator ATOP The ATOP is a device which is connected to the 3970 SKP via a serial line It makes the following functions possible automatic switching on and off of the S120 automa...

Page 11: ... is started up The number of windows for operating BS2000 and SINIX the order of the windows on the screen their size and some other properties can be changed using the relevant configuration functions Information on this can be found in the chapter entitled Configuring the system in the sections X screens and Virtual screens in the SINIX 2000 V7 5 V8 0 manual Console distribution program KVP Germ...

Page 12: ...s is possible via the SKP X When you try to make an entry in a VM2000 console window for the first time after pow ering up the SINIX system you will be requested to enter the password The configuration of VM2000 consoles requires release by means of key diskettes Access to BS2000 system administration If you want to work as a system administrator in BS2000 you must use a type EM9750 window fill in...

Page 13: ...e following controls and indicators are provided for the S120 Business Server control panel on the Business Server cabinet see page 14 EMERGENCY STOP switch see page 18 The S120 is operated using the operator terminals on the service console processor ...

Page 14: ...rver The functions of the indicators and control elements on the control panel are described below 4 1 1 Function of the indicators STATUS The STATUS indicator is an LCD display and can show alphanumeric characters The codes change when the Business Server and the IMPL are switched on No P codes should be displayed if POWER ON or IMPL has been run without errors see next page If this is not the ca...

Page 15: ...ce mode Test mode none Normal mode T Test mode maintenance mode together with the CE display Cluster status Pnnn P000 S120 switched off P001 to P599 P codes during the switching on and initialization phase as well as when switching off DOWN Display for system fault PALM Power supply error or fan error RUN CPU in RUN status WAIT CPU in WAIT status STOP CPU in STOP status LOAD IPL is being executed ...

Page 16: ... this button The lights go out immediately when you press this button again POWER ON When this button is pressed the power supplies of the entire system are switched on sequentially The order is predetermined It begins with the Business Server system components and ends with the peripheral devices connected to the PCI Power Control Interface Then an IMPL Initial Micro Program Load is carried out T...

Page 17: ...PU channel processor Furthermore the IORSF selected in the IORSF Control Frame is activated After the IMPL is terminated the P codes in the LCD display are extinguished After wards an IPL Initial Program Load of the BS2000 can be executed on the SKP This button loads another configuration or activates another IORSF A protective cover prevents the button being pressed inadvertently The system will ...

Page 18: ...switch must be pressed Figure 7 EMERGENCY STOP switch on the S120 Business Server cabinet The switch should only be used in emergencies The switch can only be reset by the service department The system can only be switched back on after the switches has been reset Use the EMERGENCY STOP switch as follows Ê Open the transparent switch cover Ê Press the red switch downwards to the O position I o UNI...

Page 19: ...f using the control panel Figure 8 Switching the S120 on and off using the control panel Switching on To switch on the entire system via the control panel the SKP must be switched on using the on off button see also the operating instructions for the SKP 2 The S120 must be switched on by pressing the POWER ON on its control panel V 24 I O channel on off facility SKP LAN Console S120 SVP internal L...

Page 20: ... call the basic menu of your window administration program by clicking on the gray window background using the right mouse button This menu contains the item Exit system Selecting this item allows you to initiate the termination of the system As a result of this selection computer name shut down is output Then carry out the following actions Ê Activate the root password field using the left mouse ...

Page 21: ... off after a certain wait time has expired You can define the shutdown command and the length of the wait period using the sysadm forms Information on operation of the FMLI interfaces can be found in the SINIX 2000 V7 5 V8 0 manual 1 Ê Select or open a SINIX screen Ê Login root or sysadm Ê Enter password Ê For login with root enter sysadm The SINIX system administration window is displayed Figure ...

Page 22: ... and off from the SKP The on off facility is linked to the SKP via the COM1 V 24 interface You access the Switching on off the host form via the sysadm menu Information on operation of the FMLI interfaces can be found in the SINIX 2000 V7 5 V8 0 manual 1 Ê Select or open a SINIX screen Ê Login root or sysadm Ê Enter password Ê For login with root enter sysadm The SINIX system administration window...

Page 23: ...ration and Powercontrol menu The Switching on off the host form is displayed Figure 11 Form Switching on off the host By entering YES for one of the two questions at the bottom of the form followed by the CHOICES key you can specify whether the S120 can be switched on or off immedi ately On no account should both questions be answered with YES Ê Press the SAVE key after filling out the form P2 P3 ...

Page 24: ... Switching on and off The Confirmation of immediate switching of the host form is displayed Figure 12 Form Confirmation of immediate switching of the host Ê Enter YES by hitting the CHOICES key The switching operating is performed after you press the SAVE key P2 P3 ...

Page 25: ... via the sysadm menu Information on operation of the FMLI interfaces can be found in the SINIX 2000 V7 5 V8 0 manual 1 Ê Select or open a SINIX screen Ê Login root or sysadm Ê Enter password Ê For login with root enter sysadm The SINIX system administration window is displayed Ê Select the menu item sinix_2000 on the UNIX System V Administration menu Ê Select the menu item host on the System Admin...

Page 26: ...down or the 3970 SKP is switched off Ê Press the SAVE key after filling out the form However it is only switched off automatically if the SINIX system is shut down using shutdown If it is shut down and restarted using shutdown i6 no switching action is carried out Configuring the automatic deactivation may have unforeseen consequences since switching off the 3970 SKP without thinking about it prop...

Page 27: ...ration menu Ê Select the menu item up_down on the SINIX 2000 system administration menu You will find a detailed description of how to configure time controlled startup shutdown in the section up_down of the SINIX 2000 V7 5 V8 0 manual The on off facility can be used to switch the S120 on and off from the SKP In addition the S120 must be configured to switch on and off automatically as part of the...

Page 28: ...terface The SKP switches during startup the S120 on After the IMPL the BS2000 system is started using the POWER ON IPL function of the SVP or using the ATOP menu The BS2000 system can be operated both via the ATOP and manually by the operator To switch off the system BS2000 must first of all be exited ATOP operator The S120 is switched off by the ATOP Therefore the ATOP sends the command usr apc b...

Page 29: ...ic switching on off of the S120 must be configured as part of the starting and shutting down procedure for the SKP see page 25 The SKP switches during startup the S120 on After the IMPL the BS2000 system is started using the POWER ON IPL function of the SVP Information on operating the DCU can be found in the data sheet 8323 Data Communi cation Unit 5 V 24 on off facility internal LAN I O channel ...

Page 30: ...Eine Dokuschablone von Frank Flachenecker by f f 1992 ...

Page 31: ...Output Resource File and start the IMPL Initial Micro Program Load This is only necessary if you want to load another IORSF specify the operating mode Native VM2000 This is only necessary if you want to change the mode setting start IPL using PROGRAM LOAD FRAME To do this you may have to redefine device parameters in the DETAIL 1 frame configure an automatic IPL POWER ON IPL The following sections...

Page 32: ...tton see chapter Operating the X window system in the SINIX 2000 V7 5 V8 0 1 manual Note on SVP operation using an alpha terminal Ê Select the SVP window by pressing the key see the section Operating the system by means of alpha terminals in the SINIX 2000 V7 5 V8 0 manual 1 The virtual screen for operating the SVP via an alpha terminal can be terminated by This locks access to the user interface ...

Page 33: ...frame By default an SVP window is configured with the label SVPST0 1 computer name to operate the SVP Figure 17 Overview of the X window system windows example You can enter into SVP operator mode at the operating terminal by clicking on the SVPST0 1 computer name window with the left mouse button ...

Page 34: ... Invoking an SVP frame Standard processing in SVP mode Figure 18 SVPST0 1 window Ê Select the Standard partner KVPHV0 function by pressing the key or Last connection KVPHV0 by pressing the key Confirm with the key S C ENTER ...

Page 35: ...ME see page 48 after closing and reopening the SVPST0 1 window or opening another SVP window on the secondary console the last frame shown in the SVPST0 1 window If the SVPST0 1 window or another SVP window on the secondary console is opened the contents of the window are not output completely Press the key This causes the screen to be refreshed i e the frame that was last output is displayed agai...

Page 36: ...ed or output are displayed Hardware related information is also output Line 22 23 System status messages and SVP messages are displayed here Line 24 Commands can be entered here Information on the hardware status is shown as of column 51 Line 25 This line is used for the status displays of the emulated operating terminal 1 21 22 23 24 25 FRAME XXXXXX YYYYYY Display area System status messages Comm...

Page 37: ...monitor system The CPU is occupied by a VM2000 guest system 28 32 CPU 0 Display of the CPU 33 37 CHP 0 Display of the channel processor CHP 0 40 45 none CLKSTP I STEP H STOP The system is in the normal state The system is in the clock stop state The system is in the instruction step state The system is in the hardware stop state 1 2 3 4 5 6 7 8 SYS DOWN CL STOP CHK STOP COMP STOP STOP WAIT RUN LOA...

Page 38: ...te The cluster is in the stop state The CPU is in the CHECK stop state The address comparison stop mode is active and the CPU is in the address comparison stop state The CPU is in the stop state The CPU is in the wait state The CPU is in the run state An IPL is executed via the CPU 58 72 none PSW The system is in the run state The system is in the stop state on the PSW address PSW Program Status W...

Page 39: ...in the remote operation state The control is with the SKP and SVP ARMSS is possible line connection is prevented 63 64 none CE The system is in the user state The system is in the maintenance state 66 67 HD FD Hard disk 2 or MO Magneto Optical disk is online A floppy disk is active or has been active in the FD drive 70 74 none TEST The system is in the user state The system is in the test state ma...

Page 40: ...he severity of the FLAG code As a rule the last is shown 6 2 4 Status displays in line 25 Status displays in line 25 of the SVPST0 window and their meaning Column Symbol Meaning 1 50 cccccccc Command input area 51 80 FFFFFFFF FFFFFFFF FLAG code Column Symbol Meaning 2 R The console is ready 3 A The SVP is active 10 25 none The SVP is ready for input 10 X Input locked 12 25 WAIT SYSTEM NOT CONNECTE...

Page 41: ... operation state The control is with the SKP and SVP ARMSS is possible line connection is prevented 31 none T The system is in user state The system is in test state maintenance state 32 none S The CPU is in the run state The CPU is in the stop state 33 none W The CPU is in the run state The CPU is in the wait state 61 68 00 Status display for hardcopy printers This display is irrelevant for SKP X...

Page 42: ...a function you can also enter a command in the command input line in all frames screen line 24 and assign a job to the SVP in this way Frames can also be selected using the FRËFrame ID e g FR ML to switch to the MODE SELECTION FRAME A command entered in line 24 takes priority over a selected frame function 6 3 1 SVP function keys An EMDS keyboard mask which must be ordered separately is used to op...

Page 43: ...S26381 K257 S26381 K258 trimodal keyboard Two part keyboard mask Order number U26118 J Z717 1 EMDS SINIX F1 F6 F3 F2 F4 F5 F7 F8 F9 F10 F11 F12 F13 F14 F15 P11 P12 P2 P6 P16 P8 P18 P4 P9 P10 P14 P19 P20 K1 K2 K3 F1 F2 F3 P1 P13 P15 P5 P7 P17 P5 P3 P4 P16 Cancel Erase Input P15 Line down Change CPU Refresh P13 Return P14 Line up Recall P12 INDEX P11 Help P1 P2 P3 P4 P5 P6 shift normal shift normal ...

Page 44: ...ontains the corresponding keys on the EMDS keyboard mask PF P Name Function PF1 Help Help functions PF 2 Index Only in CE mode switches to the index frame PF 3 Return Switches to the previous frame PF 4 Frame specific function is executed PF 5 Frame specific function is executed PF 6 Cancel Erase Input Command or input is erased PF 7 Page up The previous screen contents are displayed PF 8 Page dow...

Page 45: ... assigned PF 23 Mode Select Switches to the MODE SELECTION FRAME Erases WRITE CONSOL message on the screen e g SHUTDOWN COMPLETED Erases BEL display in screen line 25 PF 24 Mode Change Switches back and forth between FJ PROGRAM FRAME and SVP FRAME for service only if appropriate settings apply K Name Function Cancel Reset Cancel input Reset key Refresh Clear The last displayed frame is re displaye...

Page 46: ...frame name In the above example the MODE SELECTION FRAME is also shown with the ID ML Arrows and program function keys show where and with which key or combination of keys you can switch to a frame ML MODE SELECTION FRAME LD PROGRAM LOAD FRAME ST STATUS DISPLAY FRAME AD ALTER DISPLAY FRAME MA MANUAL OPERATION FRAME ME MESSAGE FRAME CH CH SUBCH STATUS DISPLAY FRAME 1 REAL CLOCK AU AUXILIARY FRAME M...

Page 47: ...e previous frame This key switches from any frame to the MODE SELECTION FRAME Frame selection Enter a frame code in the MODE SELECTION FRAME e g ST AU AU5 Change to subframes You can change to a subframe by selecting it from the main frame or from a subframe that has already been invoked This can be done with program function keys The keys are shown in the corresponding frame or subframe by select...

Page 48: ...screen By making entries in this frame and pressing you can switch to other frames or execute various basic functions FUNCTION The desired function can be selected by entry of a number listed in the EXECUTION column or a letter combination listed in the SELECTION column i MODE SELECTION FRAME E45L01G FUNCTION EXECUTION SELECTION CPU SELECT 0 1 CPU STOP LD PROGRAM LOAD ST STATUS DISPLAY 2 INTERRUPT...

Page 49: ...ed The functions are executed according to the entries in the CPU SELECT and STOP START MODE fields see table on next page 1 CPU STOP stops either the CPU selected in the CPU SELECT and STOP START MODE fields or all CPUs 2 INTERRUPT creates an external interrupt for the CPU selected in the fields CPU SELECT and STOP START MODE 3 TOD ENABLE time entry is enabled 4 SYSTEM RESET all CPUs channel proc...

Page 50: ...for the CPU in the CPU SELECT field 1 ALL CPU all CPUs are selected 2 TARGET CPU only the CPU in the CPU SELECT field is selected Note The following table shows all the functions that can be meaningfully combined Function CPU SELECT STOP START MODE Effect on CPU STOP 1 All CPU all CPUs 0 2 TARGET CPU selected CPU INTERRUPT STORE STATUS RESTART 0 2 TARGET CPU selected CPU TOD ENABLE SYSTEM RESET SY...

Page 51: ...D FUNCTION The following function is executed after the corresponding number has been entered 1 START AUTO executes IPL automatic startup 2 START FAST executes IPL fast startup 3 START DIAL executes IPL dialog startup 4 START not used 5 SYSTEM DUMP executes SLED PROGRAM LOAD FRAME BASIC E45L01G LOAD FUNCTION 1 START AUTO 2 START FAST 3 START DIAL 4 START 5 SYSTEM DUMP ENTER EXECUTE PF7 GO TO DETAI...

Page 52: ...SET1 page 71 6 4 2 1 LD PROGRAM LOAD FRAME DETAIL 1 Figure 27 PROGRAM LOAD FRAME DETAIL 1 screen By making entries in this screen and pressing the key you can control the execution of an IPL ENTER ENTER ARE YOU SURE ENTER Y OR N N Y ENTER N ENTER P7 PROGRAM LOAD FRAME DETAIL 1 E45L01G LOAD FUNCTION IPL DEVICE 2 1 START AUTO 1 PRESET GROUP 2 START FAST 2 CURRENT GROUP 3 START DIAL 3 UNIT ADDRESS 4 ...

Page 53: ...lowing function is selected after the corresponding number has been entered 1 START AUTO executes IPL automatic startup 2 START FAST executes IPL fast startup 3 START DIAL executes IPL dialog startup 4 START not used 5 SYSTEM DUMP executes SLED 6 LOAD CLEAR clears main memory before IPL 7 LOAD NON CLEAR does not clear main memory before IPL IPL DEVICE By entering the corresponding number in this f...

Page 54: ...he CURRENT GROUP 3 UNIT ADDRESS A new device address from which the operating system is to be loaded can be entered here If the IPL is terminated normally this device address is put in first position of the CURRENT GROUP If the IPL is unsuccessful the loading is not repeated PARMS A maximum of 8 characters can be entered in this field Their position and meaning are listed below MT CONTROL IPL from...

Page 55: ...nd then to cancel the procedure Switches to PROGRAM LOAD FRAME BASIC page 51 Switches to the PROGRAM LOAD FRAME DETAIL 2 page 55 6 4 2 2 LD PROGRAM LOAD FRAME DETAIL 2 Figure 28 PROGRAM LOAD FRAME DETAIL 2 screen By making an entry in this frame and pressing you can set the operating mode ENTER ENTER ARE YOU SURE ENTER Y OR N N Y ENTER N ENTER P3 P9 PROGRAM LOAD FRAME DETAIL 2 E45L01G VM MODE IPL ...

Page 56: ...s executed Ê After selecting the firmware to be loaded in the VM MODE field and entering 2 in the IPL EXECUTION field press The following prompt will then appear The operating mode must not be reset during system operation If this instruction is not heeded BS2000 will be shut down Ê Press to reload the firmware or to cancel the procedure Confirm your input with Ê After reloading the firmware press...

Page 57: ...po nents Power on off online offline normal maintenance state etc Unmounted compo nents are not displayed The memory size addressing mode MODE EXA or AVM EX EXS and availability of the SKP FTOPS2 ENABLE are important displays STATUS DISPLAY FRAME E45L01G CPU 0 0 ONL RUN CHP 0 ONL SVP SPC SYS PON CHBP 0 PON CHBP 1 PON SYSTEM INFORMATION MEMORY 1GB MODE AVM EX EXS FTOPS2 ENABLE CL 0 CPU 0 CHP 0 RUN ...

Page 58: ... program operation 2 ADRS COMPARE STOP sets mode for compare address stop 3 FIRMWARE DUMP outputs a firmware dump to tape or to magnetic tape cartridge for service only 4 HSA DUMP executes HSA dump for service only HSA Hardware Software Area X EXECUTE executes functions 1 4 MANUAL OPERATION FRAME E45L01G FUNCTION ADDRESS COMPARE STOP ADRS TYPE 1 RATE CONTROL RATE CONTROL 1 ABSOLUTE 1 PROCESS 2 LOG...

Page 59: ...pare stop if compare stop address is same as 1 ANY any address 2 OPERAND FETCH OFETCH operand read address 3 OPERAND OSTORE operands write address 4 INSTRUCTION ADRS IA instruction address 5 IA OFETCH instruction and operand read address 6 OFETCH OSTORE operand read and write address UNIT ADRS Device address for output of a firmware dump ADRS SET Compare stop address XXXX Address space larger than...

Page 60: ...pressing you can use this frame to display and change the contents of the main memory and the memory protect key It is a requirement that the CPU key is stopped beforehand see ML MODE SELECTION FRAME on page 48 FUNCTION The following function is selected after the corresponding letter has been entered A ALTER change and modify memory contents D DISPLAY display memory contents ALTER DISPLAY FRAME E...

Page 61: ...ress XXXX address space larger than 32 bits XXXXXXXX 32 bit address Special key functions When you press this key the following subframe is displayed Figure 32 ALTER DISPLAY FRAME screen subframe By making the appropriate entries and pressing the key you can use this frame to change and display the contents of important CPU registers It is a requirement that the selected CPU key is stopped beforeh...

Page 62: ...gister contents D DISPLAY display register contents FACILITY Possible displays of registers GR General register PSW Program status word CR Control register FCR Feature control register FPR Floating point register PRX Prefix register AR Access register XCR Extended control register EX EPRX Extended prefix register ADRS no input required Special key functions returns to the frame for memory display ...

Page 63: ...MM DD HH MM SS 0759 01 X2LA9 FUNCTION ST 10 27 14 47 23 0760 01 X2SA9 SSU0 10 27 14 48 56 0761 01 E2SA1 COMMAND NOT FOUND 10 27 14 48 56 0762 01 X2SA9 PF 8 10 27 14 49 14 0763 01 X2SA9 PF 3 10 27 14 50 30 0764 01 X2LA9 FUNCTION MA 10 27 14 50 35 0765 01 E2M31 CPU NOT IN STOPPED STATE 10 27 14 50 35 0766 01 X2MA9 PF 2 10 27 14 51 47 0767 01 E2MA2 UNSUPPORTED PF KEY 10 27 14 51 47 0768 01 X2MA9 PF 3...

Page 64: ...pe F fibre channels CHP NO channel processor 0 3 CHPID channel path number 000 03F CH SUBCH STATUS DISPLAY FRAME CHANNEL E45L01G CHP 0 PCHAD 0000000000000000 0000000000000000 0000000000000000 0000000000000000 0000000000000000 1111111111111111 2222222222222222 3333333333333333 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF 0123456789ABCDEF CHPID 0000000000000000 0000000000000000 000000000000000...

Page 65: ... S channel 02 without director with director 01 FD link address output port address LCUADR logical control unit address no input required PCHAD physical channel address 000 03F Special key functions Display of channels with lower addresses Display of channels with higher addresses Displaying other channels on the S120 business server is not possible P10 P11 ...

Page 66: ...g setting SVP clock 67 2 IORSF CONTROL displaying editing IORSF 68 3 RELATED SCB memory size for related SCBs 69 4 POWER STAND BY IMPL executing POWER STAND BY or IMPL 70 5 LOAD PRESET presetting LOAD FRAME 71 8 HEAD CLEANING cleaning write read head of floppy disk drive 73 9 MEMORY RECONFIGURATION reconfiguring memory 74 AUXILIARY FRAME MENU E45L01G SELECTION 1 REAL CLOCK 2 IORSF CONTROL 3 RELATE...

Page 67: ...y is pressed The SKP cyclically synchronizes the SVP clock with the SINIX time message SET TIME COMMAND COMPLETED This means that the SINIX time has to be changed when a time correction is made see the chapter System administration under SINIX in the SINIX 2000 V7 5 V8 0 1 manual Special key functions Delete input Corrections are carried out by the SVP AUXILIARY FRAME REAL CLOCK E45L01G YYYY MM DD...

Page 68: ...d 1 SET NO activates an IORSF Entry of the set number in the NEXT POWER ON RESET NO field An IMPL is then required see AU4 frame on page 70 2 PROTECT engages disengages IORSF protection from being overwritten After selecting function 2 enter P or U before the appropriate number 3 SWAP swaps two IORSFs enter the numbers in the SPECIFY SWAP NO fields AUXILIARY FRAME IORSF CONTROL E45L01G NO COMMENT ...

Page 69: ... swapped You can only make entries if you select function 3 beforehand Special key functions Sets 4 to 7 are displayed Sets 0 to 3 are displayed 6 4 8 3 AU3 AUXILIARY FRAME RELATED SCB S This frame is intended exclusively for use by the service department Figure 38 AUXILIARY FRAME RELATED SCB S screen P8 P7 i AUXILIARY FRAME RELATED SCB S E45L01G NUMBER OF RELATED SCB S 04 K NUMBER OF OCLINK CNC L...

Page 70: ... to the PCI Power Control Interface then CPU further information on this can be found on page 16 and page 20 2 IMPL executes IMPL After you have selected a function and pressed the following prompt will appear The IMPL or POWER STAND BY must not be executed during system operation If this instruction is not heeded BS2000 will be terminated abruptly Ê Press and to switch off the system or to execut...

Page 71: ...EVICE Entries in this field specify from which device an IPL should be executed 1 PRESET GROUP Up to four unit addresses can be entered in the input field for PRESET GROUP The operating system is loaded from the first device IPL In the case of an error the IPL is executed by the next device listed AUXILIARY FRAME LOAD PRESET1 E45L01G START MODE IPL DEVICE 1 1 START AUTO 1 PRESET GROUP 2 START FAST...

Page 72: ...IC PROGRAM LOAD FRAME BASIC see page 51 2 LOAD FRAME DETAIL PROGRAM LOAD FRAME DETAIL 1 s page 52 Special key functions store settings switches to LOAD PRESET2 screen Figure 41 AUXILIARY FRAME LOAD PRESET2 screen You can set the operation mode by making an entry in this frame and pressing the key VM MODE Selection of the firmware to be loaded from SVP 1 NATIVE for BS2000 operation 2 AVM EX EXS for...

Page 73: ...S120 Business Server Special key functions store settings switches to the LOAD PRESET1 screen 6 4 8 6 AU8 AUXILIARY FRAME HEAD CLEANING Bild 42 AUXILIARY FRAME HEAD CLEANING screen The AU8 frame is not intended for use on S120 as the floppy disk drive is used for mainte nance only P12 P9 AUXILIARY FRAME HEAD CLEANING E45L01G SET CLEANING DISK CL 0 CPU 0 CHP 0 RUN M FLAG CODE D90557 3 00000I00 RA M...

Page 74: ...RY FRAME MEMORY RECONFIGURATION screen The AU9 frame is not intended for use on S120 AUXILIARY FRAME MEMORY RECONFIGURATION E45L01G MEMORY RECONFIGURATION UNIT SIZE MAX ADDRESS 2 6 1 ENABLE 1 1MB 2GB 2 DISABLE 2 2MB 4GB 3 4MB 8GB 4 8MB 16GB 5 16MB 32GB 6 32MB 64GB PF6 CANCEL PF12 CATALOG CL 0 CPU 0 CHP 0 RUN M FLAG CODE D90557 3 00000I00 RA M 00 ...

Page 75: ...2000 10 23 15 43 23 LAST SEQ 0538 NODE SELF 1 14 SEQ UNIT FLAG CODE DATE TIME CT KIND LINK INFORMATION 0538 ICC A9 7M12 33 006D0I00 10 26 16 50 42 ATTN HC27 SP4 AW 026D 03 006D0I00 0537 ICC A9 7M12 33 00690I00 10 26 16 50 34 ATTN HC26 SP3 AW 0269 03 00690I00 0536 ICC A9 7M12 33 002D0I00 10 26 16 50 28 ATTN HC25 SP2 AW 022D 03 002D0I00 0535 ICC A9 7MC4 33 00640I00 10 26 16 50 18 ATTN HC24 SP1 AW XX...

Page 76: ...is not intended for use PERFORMANCE ANALYZER FRAME E45L01G FUNCTION STATUS DISABLE STOP 1 ENABLE ITEM SELECT LOGGING STOP 2 DISABLE 3 START DISPLAY CH BUSY LEVEL 4 START CH BUSY 0 GREEN 30 5 STOP 31 WHITE 100 6 LOGGING START 7 LOGGING STOP INTERVAL TIME 8 CPU LOG DISPLAY SAMPLING 2 SEC 9 CH LOG DISPLAY LOGGING 1 MIN CL 0 CPU 0 CHP 0 RUN M FLAG CODE D90557 3 00000I00 RA M 00 ...

Page 77: ...PST0 1 computer name window created a link to the KVPHV0 and entered the correct password The MODE SELECTION FRAME is displayed Figure 46 MODE SELECTION FRAME screen MODE SELECTION FRAME E45L01G FUNCTION EXECUTION SELECTION CPU SELECT 0 1 CPU STOP LD PROGRAM LOAD ST STATUS DISPLAY 2 INTERRUPT MA MANUAL OPERATION STOP START MODE AD ALTER DISPLAY 3 TOD ENABLE ME MESSAGE 1 ALL CPU CH CH SUBCH STATUS ...

Page 78: ...RY FRAME MENU screen Invoking IORSF Control Frame Ê Enter 2 in the SELECTION field Press If the frame code AU2 is entered in the MODE SELECTION FRAME or the FR AU2 command is entered in line 24 the following frame is displayed ENTER ENTER AUXILIARY FRAME MENU E45L01G SELECTION 1 REAL CLOCK 2 IORSF CONTROL 3 RELATED SCB 4 POWER STAND BY IMPL 5 LOAD PRESET 8 HEAD CLEANING 9 MEMORY RECONFIGURATION CL...

Page 79: ...3 Now you want to activate the IORSF with the number 2 Ê Enter 1 in the FUNCTION field Press Ê Enter 2 in the NEXT POWER ON RESET NO field and press AUXILIARY FRAME IORSF CONTROL E405L01G NO COMMENT 0 DATE TIME 1 DATE TIME 2 S1200001S1200001 STANDARD OSDV1 4 09 11 00 DATE 2000 11 08 TIME 15 53 P 3 S1200001S1200001 STANDARD OSDV1 4 20 11 00 DATE 2000 11 17 TIME 10 14 FUNCTION CURRENT NO 3 1 SET NO ...

Page 80: ... displayed Figure 49 AUXILIARY FRAME POWER STAND BY IMPL screen Ê Enter 2 in the FUNCTION field to execute an IMPL Then press The following prompt appears The IMPL must not be executed during system operation If this instruction is not heeded BS2000 will be terminated abruptly Ê Press to execute the IMPL or to cancel the procedure Confirm your entry with P3 ENTER AUXILIARY FRAME POWER STAND BY IMP...

Page 81: ...OWER ON The LOAD FRAME should always be displayed as PROGRAM LOAD FRAME DETAIL 1 Conditions You must have selected the SVPST0 1 computer name window created a link to the KVPHV0 and entered the correct password The MODE SELECTION FRAME is displayed on the screen see page 77 Invoke AUXILIARY FRAME LOAD PRESET1 screen Ê Enter AU in the FUNCTION field and then press or Ê enter the FR AU command in li...

Page 82: ...ROUP A maximum of three further addresses can be entered Entry in our example 0214 POWER ON IPL Enter 1 for automatic IPL after POWER ON INITIAL FRAME Enter 2 for a detailed display of the LOAD FRAME Storing parameters Ê Press the key The values entered are saved and thus made known to the SVP These settings are accessed for each IPL AUXILIARY FRAME LOAD PRESET1 E45L01G START MODE IPL DEVICE 1 1 S...

Page 83: ... Conditions You must be in the AUXILIARY FRAME LOAD PRESET1 screen Invoke AUXILIARY FRAME LOAD PRESET2 screen Ê Press the key in the AUXILIARY FRAME LOAD PRESET1 screen The AUXILIARY FRAME LOAD PRESET2 screen is displayed Figure 51 AUXILIARY FRAME LOAD PRESET2 screen VM MODE Enter 2 for VM2000 operation START IPL NO Always enter 1 for automatic startup P9 AUXILIARY FRAME LOAD PRESET2 E45L01G VM MO...

Page 84: ...tup IPL device is specified manually by the entry of the unit address here loading the VM2000 from a device with the unit address FDE0 Conditions You are in the AUXILIARY FRAME LOAD PRESET2 screen Invoking the PROGRAM LOAD FRAME DETAIL 1 screen Ê Press the key to return to the MODE SELECTION FRAME Ê Enter the frame code LD and press or Ê enter the FR LD command in line 24 and press After entering ...

Page 85: ...ct the entries in DETAIL 2 FRAME see section 6 5 6 Setting operating mode via PROGRAM LOAD FRAME DETAIL 2 on page 87 In our example VM MODE NATIVE i e the firmware for the BS2000 operation is loaded This setting must be changed in DETAIL 2 FRAME for this example Swap to PROGRAM LOAD FRAME DETAIL 2 Ê Press the key PROGRAM LOAD FRAME DETAIL 1 E45L01G LOAD FUNCTION IPL DEVICE 2 1 START AUTO 1 PRESET ...

Page 86: ... the CURRENT GROUP field by the SVP Entering a 2 in the IPL DEVICE field loads the operating system from the desired device PARMS Enter 1 in the first position of the field to load VM2000 MT CONTROL 1 is preset This parameter is only important for loading from tape PROGRAM LOAD FRAME DETAIL 1 E45L01G LOAD FUNCTION IPL DEVICE 3 2 1 START AUTO 1 PRESET GROUP 2 START FAST 2 CURRENT GROUP 3 START DIAL...

Page 87: ...dure Confirm your entry with 6 5 6 Setting operating mode via PROGRAM LOAD FRAME DETAIL 2 The operating mode can be reset using the PROGRAM LOAD FRAME DETAIL 2 This selects the appropriate firmware for running BS2000 or VM2000 The following are specified in the example below VM2000 operating mode executing IPL after reloading the firmware Conditions You must be in the PROGRAM LOAD FRAME DETAIL 1 s...

Page 88: ... new setting is displayed under VM MODE in the DETAIL 2 STATUS field Now VM MODE AVM EX EXS is displayed The firmware is relocated before the IPL is executed You can execute the IPL by completing the PROGRAM LOAD FRAME DETAIL 1 and pressing the key see page 84 Take care of filling in the PARMS field correctly PROGRAM LOAD FRAME DETAIL 2 E45L01G VM MODE IPL EXECUTION 2 1 1 NATIVE 1 ENABLE 2 AVM EX ...

Page 89: ...orresponding digits and to select and start the functions provided on the main KVP function menu Ê Select function 1 and press the key Ê Enter the password for the cons0 user ID Confirm your input by pressing the key You can then enter BS2000 commands or respond to queries from the BS2000 system Your input is transferred to BS2000 when you press the key You will find further information on the fun...

Page 90: ...Eine Dokuschablone von Frank Flachenecker by f f 1992 ...

Page 91: ... IOP MCU SVP SCI SPC or PCI system components is defective the service department must carry out the necessary corrective measures Wie Sie der Business Server S120 über Hardware Fehler informiert erfahren Sie im folgenden Abschnitt Problems with the S120 page 91 Displays if there is a hardware error page 92 Carrying out a system dump page 93 Measures to take if there is an I O channel or the I O p...

Page 92: ...ag code display in line 24 of the SVPST0 screen The Flag code FF FF can have different meanings and can therefore require different measures A WRITE CONSOL message is displayed It can be deleted with the key This does not delete the Flag code display A warning is issued e g if the room temperature is too high The cause of the error must be eradicated System operation can continue in the meantime A...

Page 93: ... be found in the Introductory Guide to Systems Support 6 manual 8 1 3 Measures to take in the case of defective I O channels or I O processor If an S120 I O channel is defective you can perform the following after consulting the service department Ê Disable defective I O channel during operation If an I O channel has failed due to a hardware failure it is automatically disabled If not you can disa...

Page 94: ...ut Processor MCU Memory Control Unit SVP Service Processor SCI System Control Interface SPC System Power Controller oder PCI Power Control Interface system components fails you may not be able to continue working with the S120 If the failure of one of these components causes a complete system failure you can carry out the following actions after consultation with the service department Ê execute a...

Page 95: ...of the window administration program enter the password select Restart and Start see also page 20 If this is not possible Switch off SKP with the OFF switch and then switch it on again A shutdown command is sent to BS2000 and it may be terminated see also page 20f and the section entitled up_down in the SINIX 2000 V7 5 V8 0 1 manual If you configurate the automatic switch off see page 25 also the ...

Page 96: ...o select a window You can use the keys to move between the windows of the X Windows window system The following key combinations make your work easier Invoke SINIX login screen on console Invoke SINIX Windows Invoke SINIX login screen Reboot command SINIX not yet loaded ALT TAB ALT SysRq h ALT SysRq P1 ALT SysRq P2 ALT CTRL DEL ...

Page 97: ...r DS2000 are ready for use This includes helpful information on con figuring the systems and a description of important functions for system operation and administration 2 3970 SKP 3970 Channel Adapter Operating Manual Target group The manual addresses privileged users operators system administrators Contents The manual contains all the information required to be able to operate the hardware of th...

Page 98: ...of response when problems occur The TELESERVICE TSB component is the interface of the BS2000 system to the TELESERVICE center 5 8323 Data Communication Unit SINIX Data Sheet Contents The 8323 Data Communication Unit DCU makes it possible to interconnect display terminals printers or computers with asynchronous interfaces via dialup telephone connec tions anywhere in the world 6 BS2000 OSD BC V4 0 ...

Page 99: ...ME AU4 POWER STAND BY IMPL 70 AUXILIARY FRAME AU5 LOAD PRESET1 71 LOAD PRESET2 72 AUXILIARY FRAME AU8 HEAD CLEANING 73 AUXILIARY FRAME AU9 MEMORY RECONFIGURATION 74 B BS2000 console window 89 C carrying out a system dump 93 CH SUBCH STATUS DISPLAY FRAME CHANNEL 64 configuration 8 levels 8 console window selecting 89 controls and indicators 13 D display hardware errors 92 hardware status 40 display...

Page 100: ...operating frames 42 operating mode 83 operation of the S120 hardware components 9 software components 11 operators 98 overview of program keys 44 P PCI Power Control Interface 94 defective 94 problems with the S120 91 processing unit defective 94 PROGRAM LOAD FRAME BASIC LD 51 DETAIL 1 52 85 DETAIL 2 55 88 R RFI suppression 3 S S120 control panel 14 button functions 16 function of the indicators 1...

Page 101: ...ective 94 keys 42 operating frames 31 SVPST0 1 window password entry 35 switching between user frames 46 on off the host form 23 26 the S120 on off manually 19 switching the S120 on off automatically 25 from a remote system 29 from SKP 22 time driven 27 using ATOP 28 using the control panel 19 system component defective 94 system operation 9 system status messages 38 systems support 98 U user fram...

Page 102: ......

Page 103: ...zation control 12 4 Controls and indicators 13 4 1 Control panel on the S120 Business Server cabinet 14 4 1 1 Function of the indicators 14 4 1 2 Button functions 16 4 2 EMERGENCY STOP switch 18 5 Switching the S120 Business Server on and off 19 5 1 Switching the S120 on and off using the control panel 19 5 2 Switching the S120 on and off from the SKP 22 5 3 Automatic switching on off of the S120 ...

Page 104: ...ERATION FRAME 58 6 4 5 AD ALTER DISPLAY FRAME 60 6 4 6 ME MESSAGE FRAME 63 6 4 7 CH CH SUBCH STATUS DISPLAY FRAME CHANNEL 64 6 4 8 AU AUXILIARY FRAME MENU 66 6 4 8 1 AU1 AUXILIARY FRAME REAL CLOCK 67 6 4 8 2 AU2 AUXILIARY FRAME IORSF CONTROL 68 6 4 8 3 AU3 AUXILIARY FRAME RELATED SCB S 69 6 4 8 4 AU4 AUXILIARY FRAME POWER STAND BY IMPL 70 6 4 8 5 AU5 AUXILIARY FRAME LOAD PRESET1 71 6 4 8 6 AU8 AUX...

Page 105: ...93 8 1 3 Measures to take in the case of defective I O channels or I O processor 93 8 1 4 Measures to take in the case of processing unit failure 94 8 1 5 Measures to take in the case of defective IOP MCU SVP SCI SPC PCI system compon ents 94 8 2 Problems with the service console processor SKP 95 8 3 Important key combinations 96 Related publications 97 Index 99 ...

Page 106: ......

Page 107: ...ate the S120 Business Server It presents the SVP frames and describes the standard tasks for operators using these frames Edition April 2001 File s120 pdf Copyright Fujitsu Siemens Computers GmbH 2001 All rights reserved Delivery subject to availability right of technical modifications reserved All hardware and software names used are trademarks of their respective manufacturers ...

Page 108: ...erver U41182 J Z126 1 74 Fujitsu Siemens computers GmbH User Documentation 81730 Munich Germany Fax 0700 372 00000 e mail manuals fujitsu siemens com http manuals fujitsu siemens com Comments Suggestions Corrections Submitted by ...

Page 109: ...tsu com Copyright Fujitsu Technology Solutions 2009 Hinweise zum vorliegenden Dokument Zum 1 April 2009 ist Fujitsu Siemens Computers in den alleinigen Besitz von Fujitsu übergegangen Diese neue Tochtergesellschaft von Fujitsu trägt seit dem den Namen Fujitsu Technology Solutions Das vorliegende Dokument aus dem Dokumentenarchiv bezieht sich auf eine bereits vor längerer Zeit freigegebene oder nic...

Reviews: