Check the status of power units with the show environment command.
Command Execution Example
(ET-7648BRA-FOS) #show environment
Temperature Sensors:
Unit Sensor Description Temp (C) State Max_Temp (C)
---- ------ ---------------- ---------- -------------- --------------
1 1 MAC 38 Level 1 41
1 2 10GE 39 Level 1 41
1 3 System CPLD 40 Level 1 44
1 4 CPU 31 Level 1 35
Fans:
Unit Fan Description Type Speed Duty level State
---- --- -------------- --------- ------------- ------------- --------------
1 1 Fan-1 Removable 10031 52% Operational
1 2 Fan-2 Removable 9929 52% Operational
1 3 Fan-3 Removable 9929 52% Operational
1 4 Fan-4 Removable 9929 52% Operational
1 5 Fan-5 Removable 9929 52% Operational
1 6 Fan-6 Removable 10031 52% Operational
Power Modules:
Unit Power supply Description Type State
---- ------------ ---------------- ---------- --------------
1 1 PSU-1 Removable Operational
1 2 PSU-2 Removable Operational
Power Consumption:
Unit Power supply Current (mA) Voltage (mV) Watt (mW)
---- ------------ ------------ ------------ ------------
1 1 8758 11869 103948
1 2 0 0 0
Battery Status: GOOD
Please confirm the State of Power Modules are “Operational”.
【
Cold Swap
】
: The case in which replaced with power-off of the switch
1.
Plug out the power cable from the failed power unit connector.
2.
Plug out the power cable from another power unit connector to power off the
switch.
3.
Hold the handle of the power unit with lock released, and pull out the failed
power unit.
Before replacing the power unit, please confirm that the switch is properly
fixed to the rack.
4.
Replace the power unit with a spare parts. Insert
5.
Connect the device to the terminal PC (FST-S) with a serial cable.
6.
Plug in the power cable to the power connector.