Hot-swap Power Supply Units
Hot-plug/hot-swap Components
8.1.2
Replacing a Hot-swap Power Supply Unit
Figure 29: Unlocking and removing the power supply unit
V
CAUTION!
Before replacing a non defective power supply unit in a non-redundant
configuration (only one power supply unit present) the server must be
switched OFF.
Ê
Remove the cable from the installed power supply unit.
Ê
Turn the transport lock (a) 45° counterclockwise (1) and pull it out (2).
Ê
Slide the locking bar of the installed power supply unit towards the power
plug (3) and remove the power supply unit from the mounting location in the
direction marked (4).
Ê
Open the transport lock of the new power supply unit, insert and lock it into
the free mounting location in the reverse order.
I
Make sure that the power supply unit engages correctly in the mounting
frame and is locked in position.
This is the only way to avoid the power supply unit being shaken out of
its mountings and damaged during transport.
Ê
Connect up the power supply unit.